semi合集-English.pdf - 第3758页

SEMI F5-1101 © SEMI 1990 , 2001 2 4 Referenced Stand ards 4.1 SEMI Standards SEMI S2 — Enviro nmental, Health, and Sa fety Guide line for Se mico nduc tor Manufa ctur ing E quip ment SEMI S5 — Safety Guideline f or Flo w…

100%1 / 7923
SEMI F5-1101 © SEMI 1990, 20011
SEMI F5-1101
GUIDE FOR GASEOUS EFFLUENT HANDLING
This guide was technically approved by the Global Environmental Health & Safety Committee and is the
direct responsibility of the North American Environmental Health & Safety Committee. Current edition
approved by the North American Regional Standards Committee on August 27, 2001. Initially available at
www.semi.org September 2001; to be published November 2001. Originally published in 1990.
NOTICE: This document, as balloted, is intended to
replace SEMI F5-90 in its entirety.
NOTICE: Paragraphs entitled “NOTE” are not an
official part of this guide and are not intended to modify
or supersede the official guide. These have been
supplied by the Task Force to enhance usage of the
guide.
1 Purpose
1.1 The purpose of this guide is to provide the
semiconductor industry with the general knowledge and
background information for understanding the
principles of exhaust systems.
1.2 It includes suggestions for layout and selection as
well as application of appropriate methods and
equipment for abating emissions.
1.3 This guide is intended for use in abatement
selection for both gaseous and particulate contaminant
materials potentially emitted from semiconductor
manufacturing facilities.
2 Scope
2.1 Applicability — This guide presents a review and
evaluation of available information including:
Chemical and physical properties of chemical
compounds and elements, that are, or may be,
released from semiconductor manufacturing
operations,
Some current industry practices for separating
exhaust systems for different groups of materials,
Potential methods for abating emissions of gaseous
and particulate contaminants exhausted from
semiconductor manufacturing operations at “End-
of-Pipe”,
Potential methods for abating emissions of gaseous
and particulate contaminants exhausted from
semiconductor manufacturing processes at “Point-
of-Use” and reasons why they should be used for
some processes,
Standard industry methods of recovery,
replacement, and “usage reduction” for minimizing
release of materials.
2.2 Contents — This document contains the following
sections:
1. Purpose
2. Scope
3. Limitations
4. Referenced Standards
5. Terminology
6. Philosophy
7. Classification of Emissions
8. End-of-Pipe Abatement Technologies
9. Point-of-Use (POU) Abatement Technologies
10. Provisions for Emergency Release
11. Summary Table
12. Alternative Approaches
13. Related Documents
Appendix 1 — End-of-Pipe Abatement Design
Appendix 2 — POU Abatement Technology Types
2.3 This guide does not purport to address all of the
safety issues associated with its use. It is the
responsibility of the users of this guide to establish
appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
3 Limitations
3.1 This guide makes only a few recommendations
regarding the fire protection aspects of exhaust systems.
Additional
recommendations on the risk assessment of
systems, compatibility of materials, and the potential
need for use of non-combustible materials or the fitting
of fire detectors, sprinklers etc., are within the scope of
other documents.
3.2 Methods for treating solid or liquid waste (created
by emission abatement processes) and methods for
recovery of gases are not discussed in this document.
SEMI F5-1101 © SEMI 1990, 2001 2
4 Referenced Standards
4.1 SEMI Standards
SEMI S2 — Environmental, Health, and Safety
Guideline for Semiconductor Manufacturing Equipment
SEMI S5 — Safety Guideline for Flow Limiting
Devices
SEMI S8 — Safety Guidelines for Ergonomics
Engineering of Semiconductor Manufacturing
Equipment
4.2 Code of Federal Regulations United States
Environmental Protection Agency
1
40 CFR Part 63 (Clean Air Act 112 (b)(1))
4.3 Uniform Codes
2
Uniform Fire Code Article 80 — Hazardous
Material
NOTE 1: Unless otherwise indicated, all documents cited
shall be the latest published versions.
5 Terminology
5.1 Abbreviations and Acronyms
5.1.1 CVD — Chemical Vapor Deposition
5.1.2 EPI — epitaxial deposition
5.1.3 HAP — Hazardous Air Pollutants [as defined by
40 CFR Part 63 (Clean Air Act 112 (b)(1))
5.1.4 PFC — perfluorocompounds
5.1.5 POU — Point of use
5.1.6 VOC — Volatile Organic Compounds
5.2 Definitions
5.2.1 classification of emissions — understanding the
composition of process exhausts.
5.2.2 efficiency — the ratio (or fraction or proportion)
of removed chemical species to its input amount
5.2.3 End-of-Pipe Abatement — abatement
technologies that can be fitted at the discharge point of
the exhaust system.
5.2.4 flow capacity — the maximum flow any specific
equipment can handle.
5.2.5 occupational exposure limits (OELs) — for the
purpose of this document, OELs are generally
established on the basis of an eight-hour workday.
1 United States Government Code of Federal Regulations, free from
the web site at http://www.epa.gov
2 International Conference of Building Officials (ICBO), 5360
Workman Mill Road, Whittier, CA 90601-2298
Various terms are used to refer to OELs, such as
permissible exposure levels, Threshold Limit Values®,
maximum acceptable concentrations, maximum
exposure limits, and occupational exposure standards.
However, the criteria used in determining OELs can
differ among the various countries that have established
values. Refer to the national bodies responsible for the
establishment of OELs. (Threshold Limit Value is a
registered trademark of the American Conference of
Governmental Industrial Hygienists.)
5.2.6 Point-of-Use Abatement — abatement
technologies that can be fitted at the point of discharge
of the gaseous emission from semiconductor process
equipment. These devices are also called exhaust
conditioners.
5.2.7 removal capacity — amount of a species which
can be removed.
5.2.8 usage reduction — reducing the total volume of
process chemicals requiring abatement.
6 Philosophy
6.1 Gaseous mixtures potentially emitted from
numerous processes could also produce hazards within
exhaust ducts.
6.2 With increasing legal requirements worldwide on
both worker safety and general environmental
protection, more effective exhaust management is
required.
6.3 This demands a detailed understanding of the
chemical and physical properties of the chemical
compounds being emitted from processes, and of the
conditions under which they are released.
6.4 Careful design of the abatement systems is required
to attain both high efficiency and maximum economy.
7 Classification of Emissions
7.1 The following fundamental points regarding
exhaust emissions should be considered:
Exhaust contaminants might be solely the material
used in the process (e.g., isopropyl alcohol (IPA)
from a rinse chamber)
In plasma and thermal chambers many reactions
occur, both those desired and others; therefore by-
products are also key components of exhaust
emissions.
In theory, most possible combinations of the
elements in the input gases may be found as
compounds in the exhaust. In practice, the main
components will be the unused process gas (the
percentage consumed in the process varies, and
SEMI F5-1101 © SEMI 1990, 20013
may be as low as 10%). Additional by-products
will have different and sometimes more hazardous
properties.
7.2 Considerable research has been conducted into
various hazardous by-products of processes, from
explosive solids to organochlorine compounds with
mutagenic properties. (See Sections 13.1 through
13.3.)
7.3 In considering selection of exhaust systems and
abatement technology, it is essential to review all the
materials likely to be present in the exhaust.
7.4 Contributions from the materials on the wafer must
also be considered, as they often cause blocked
exhausts (e.g., aluminum etches produce aluminum
chloride (a by-product of removal of aluminum from
the wafer with chlorinated gases)).
7.5 Processes that produce specific hazardous by-
products should be evaluated for appropriate point-of-
use abatement technology before discharge to an
exhaust system.
7.6 Gaseous and particulate contaminants emitted from
semiconductor manufacturing can be divided
conveniently into nine major groups, each of which
might justify its own exhaust system.
7.6.1 Group-1 Acid — Easily hydrolyzable acids, (e.g.,
hydrogen chloride hydrolyzes into hydrochloric acid.)
7.6.2 Group-2 Acid aerosols (“difficult–to-scrub”)
This group includes acids that generate aerosols and
that are not easily removed by simple water scrubbers
(e.g., aqua regia, sulfuric and nitric).
NOTE 2: High concentrations of easily soluble acids will also
fall into the “difficult-to-scrub” category.
7.6.3 Group-3 Ammonia — Exhaust streams
containing ammonia
7.6.4 Group-4 Volatile Organic Compounds (VOCs)
— Exhausts containing volatile organic compound
vapors or flammable gas discharge requiring
destruction.
7.6.5 Group-5 Pyrophoric — Exhausts containing
pyrophoric gases.
7.6.6 Group-6 Emergency Release Discharges
Enclosures are provided with additional exhausts to
contain sudden unanticipated releases of gas from
cylinders, etc.
7.6.7 Group-7 Special/Direct — Additional exhausts
used to keep specific gases separate for recovery
purposes (e.g., hydrogen (H
2
) reclamation from EPI or
PFC reclamation from CVD tools, Oxides of Nitrogen
(NO
x
)).
7.6.8 Group-8 General Exhaust Systems without End-
of-Pipe Treatment — Exhaust of heat or post-treatment
exhaust from POU abatement systems.
7.6.9 Group-9 Highly Toxic Gas Exhaust — Highly
toxic gases especially those with poor warning
properties (e.g., arsine, phosphine, diborane, germane).
The end user has a primary responsibility to prevent
discharge of these gases above a regulated level (e.g.,
usually one-half (1/2) of Immediately Dangerous to
Life and Health (IDLH) levels).
NOTE 3: Facility exhaust systems may be called by a number
of different names such as: Acid, Corrosive, Ammonia,
Scrubbed, VOC, Solvent, Incinerated, Highly Toxic, Toxic,
Dedicated, Special, PFC, General, Heat, Treated, or others.
The actual facility exhaust system name, and what groups are
routed to each system, will vary by factory and by country.
7.7 The groups listed in Section 7.6 are not a definitive
division, but represent a summation of common
industry practice for separation. The division is based
on three basic principles:
avoiding mixing of incompatible gases in the
exhaust,
potential need for different end-of-pipe abatement
technologies, and,
keeping materials separate for recovery.
7.8 The number of separate exhaust systems used is
entirely a decision for each facility, based on the
following:
processes and chemicals used,
the number of each type of process,
whether recovery of gases is required,
whether point-of-use (POU) abatement is installed,
and
compatibility of emissions with each other or the
effluent handling system.
7.9 In theory, if POU abatement systems are fitted to
all sources of gaseous effluent all exhaust could then be
combined into a single exhaust system.
7.9.1 In practice most facilities operate a compromise
between the two extremes with two to four separate
exhaust systems and point-of-use abatement systems
fitted only to certain sources. The decision (as to which
combination to use) will often be based on economic
and space constraints.
7.9.2 Safety and environmental factors listed below,
should always be considered first when determining
specific gaseous sources that require POU abatement
systems.