SEMI E130.1-1104 © SEMI 2004 5 Service SECS-II Field Values Req. Description RCMD “SET-CONTROL- MAP” Y CPNAME “CONTROLMAP” Y ControlMap parameter. CPVAL A [n] Control Map identifier. CPNAME “X” N X parameter. CPVAL U4 X …

100%1 / 7923
SEMI E130.1-1104 © SEMI 2004 4
Service SECS-II Field Values Req. Description
RCMD “LOAD- TEST-
SUBST”
Y
CPNAME “SUBSTLOCID” Y SubstLocID parameter.
LOAD- TEST-SUBST
CPVAL A [n] Substrate Location containing the test
substrate.
LOAD-SUBSTRATE RCMD “LOAD-SUBSTRATE” Y
RCMD “LOCKOUT-
CONTROL”
Y
CPNAME “LOCKOUT” N Lockout parameter.
LOCKOUT-CONTROL
CPVAL BOOLEAN True = Lockout console control.
RCMD “MOVE” Y At least one of X, Y, or Z parameter must
be supplied. An omitted X, Y, or Z is
equivalent to specifying zero.
CPNAME “X” N X parameter.
CPVAL U4 Relative step value in X direction.
CPNAME “Y” N Y parameter.
CPVAL U4 Relative step value in Y direction.
CPNAME “Z” N Z parameter.
MOVE
CPVAL U4 Relative step value in Z direction.
RCMD “MOVE-ABS” Y At least one of X, Y, or Z parameter must
be supplied. An omitted X, Y, or Z is
equivalent to specifying current value.
CPNAME “X” N X parameter.
CPVAL U4 Absolute index in X direction.
CPNAME “Y” N Y parameter.
CPVAL U4 Absolute index in Y direction.
CPNAME “Z” N Z parameter.
MOVE-ABS
CPVAL U4 Absolute index in Z direction.
RCMD “MOVE-SUB-STEPS” Y At least one of XSubstep, YSubstep or
Zsubstep must be supplied. An omitted
XSubstep, YSubstep, or ZSubstep is
equivalent to specifying zero.
CPNAME “XSUBSTEP” N XSubstep parameter.
CPVAL F4 Relative substep value in X direction.
CPNAME “YSUBSTEP” N YSubstep parameter.
CPVAL F4 Relative substep value in Y direction.
CPNAME “ZSUBSTEP” N ZSubstep parameter.
MOVE-SUB-STEPS
CPVAL F4 Relative substep value in Z direction.
MOVE-TO-REF-DIE RCMD “MOVE-TO-REF-DIE” Y
RESET-CONTACT-CNT RCMD “RESET-CONTACT-
CNT”
Y
RCMD “RESET-CONTROL-
MAP”
Y If coordinates are designated, both X and Y
coordinate must be provided.
CPNAME “X” N X parameter.
CPVAL U4 X coordinate value.
CPNAME “Y” N Y parameter.
RESET-CONTROL-MAP
CPVAL U4 Y coordinate value.
RCMD “SET-PROBE-CARD-
ID”
Y
CPNAME “PROBECARDID” Y Probe Card ID parameter.
SET-PROBE-CARD-ID
CPVAL A [n] Probe card identifier.
SEMI E130.1-1104 © SEMI 2004 5
Service SECS-II Field Values Req. Description
RCMD “SET-CONTROL-
MAP”
Y
CPNAME “CONTROLMAP” Y ControlMap parameter.
CPVAL A [n] Control Map identifier.
CPNAME “X” N X parameter.
CPVAL U4 X coordinate value.
CPNAME “Y” N Y parameter.
SET-CONTROL-MAP
CPVAL U4 Y coordinate value.
UNLOAD-SUBSTRATE RCMD “UNLOAD-
SUBSTRATE”
Y
RCMD “UNLOAD-TEST-
SUBST”
Y
CPNAME “SUBSTLOCID” Y SubstLocID parameter.
UNLOAD-TEST-SUBST
CPVAL A [n] Target substrate location.
RCMD “UNLOAD-
ALLSUBSTRATES”
Y
CPNAME “SUSPEND” N SUSPEND parameter.
UNLOAD-
ALLSUBSTRATES
CPVAL BOOLEAN If TRUE, causes substrate occupying chuck
to be suspended.
ONLINE-LOCAL RCMD “ONLINE-LOCAL” Y
6 Variable Data Item Mapping
6.1 The purpose of this section is to define the list of variable items required by SEMI E130. Values of these
variables will be available to the host through collection event reports and host status queries.
6.2 Requirements
6.2.1 Any supplier-defined variables shall be documented in the same format used by this document. The following
minimum information is required:
<variable name> Class: <ECV, SV, or DVVAL> Format: <SML>
Description: <If class = DVVAL, description must contain statement of when data is valid.>
<If format = ASCII, then a length is required. It is assumed to be left-justified unless otherwise noted.>
6.3 Data Types
6.3.1 Equipment Constants (ECVs) can be changed by the host using S2,F15 (New Equipment Constant Send). The
operator may be able to change some values, but the equipment does not change the values on its own. The value of
an equipment constant may be queried by the host at any time, using the S2,F13/14 transaction. They reside in non-
volatile memory of the equipment. Equipment constants remain in effect until they are overwritten either by manual
entry or by a S2,F15.
6.3.2 Status Variables (SVs) are valid at all times. An SV may not be changed by the host but may be changed by
the equipment or operator. The value of status variables may be queried by the host at anytime using the S1,F3/4 or
S6,F19/20 transactions.
6.3.3 DVVALs are variables that are valid only upon the occurrence of specific collection events. An attempt to
read a variable item at the wrong time does not generate an error, but the data reported may not have relevant
meaning.
6.4 For multiple sites scenarios, if a variable is described as List by number of sites, then a list is expected, one
value for each site.
SEMI E130.1-1104 © SEMI 2004 6
Table 4 Variable Item Mapping Table
Variable Name Description Class SECS-II Type
ContactCount The number of times the probe card has come in
contact with a substrate.
SV U2
DieXCoordinate The coordinate of the die in the x direction (column). SV I2
DieYCoordinate The coordinate of the die in the y direction (row). SV I2
DieZPosition The position of the Chuck Z-axis in microns. A
user/supplier defined unit of measure other than
microns is permissible and must be documented.
SV F4
DieZCoordinate The coordinate of the die in the z direction. SV I2
InspectionResult Result of the last inspection. SV BOOLEAN
MinXStep The minimum step size in microns in the X direction. SV F4
MinYStep The minimum step size in microns in the Y direction. SV F4
MinZStep The minimum step size in microns in the Z direction
(Alternative user-defined unit of measure may be
specified for the Z motion).
SV F4
ProbeCardId The ID of the Probe Card. SV A [25]
TaskID The ID of the service task being performed. SV A [50]
NOTICE: SEMI makes no warranties or representations as to the suitability of the standards set forth herein for any
particular application. The determination of the suitability of the standard is solely the responsibility of the user.
Users are cautioned to refer to manufacturer's instructions, product labels, product data sheets, and other relevant
literature, respecting any materials or equipment mentioned herein. These standards are subject to change without
notice.
By publication of this standard, Semiconductor Equipment and Materials International (SEMI) takes no position
respecting the validity of any patent rights or copyrights asserted in connection with any items mentioned in this
standard. Users of this standard are expressly advised that determination of any such patent rights or copyrights, and
the risk of infringement of such rights are entirely their own responsibility.
Copyright by SEMI® (Semiconductor Equipment and Materials
International), 3081 Zanker Road, San Jose, CA 95134. Reproduction of
the contents in whole or in part is forbidden without express written
consent of SEMI.