SEMI E129-1103 © SEMI 2003 19 • ESD STM7.1 can be used to measure the resistance to a groundable point and res istance point-t o -point for flooring, • ANSI ESD STM12 .1 can be used t o measure t he resistance to a groun…

SEMI E129-1103 © SEMI 2003 18
furniture, equipment, materials handled by the
equipment, and any ESD-protective materials can be
rapidly, and harmlessly, neutralized. Providing a path
to ground brings everything to the same “zero” voltage
electrical potential. All conductors in the environment,
including personnel, should be electrically connected
and attached to a known ground. It is important to note
that insulators cannot lose their electrostatic charge by
attachment to ground. Other charge-mitigating
techniques (discussed in later sections) are required to
neutralize excessive charge (i.e., electric field
reduction) on the necessary insulators used in the
electrostatic protective area (EPA), if their charge is
considered a risk to sensitive parts handled in that
location.
R2-3.2 Grounding methods and their measurement are
described in detail in ESD S6.1. Information on
electrical power grounding, which is a separate issue
not addressed in this document, may be found in
ANSI/NFPA 70, ANSI/IEEE STD 142, or appropriate
country guidelines.
R2-3.3 Grounded conductors cannot maintain a static
charge for very long. This is primarily dependent on
the overall electrical resistance of the system. System
resistance includes the resistance of the item being
grounded, the contact resistance at the interface
between items and the resistance in the actual
grounding path. Since resistance of the system ground
path determines the rate of discharge, it determines the
amount of protection provided to ESD-sensitive
devices. A permanent connection to ground will
certainly prevent any charge from building up on an
object and its subsequent transfer to an ESD-sensitive
device. However, if an ungrounded, charged object
contacts a material with too low a resistance to ground,
a damaging discharge may occur. Even if no direct
damage occurs, the ESD event creates EMI that may
affect the operation of nearby production equipment.
R2-3.4 It should be noted that attaching a large
metallic object (e.g., a stainless steel work surface) to
ground through a high resistance will not prevent a
discharge from occurring to the large metallic object.
The high capacitance of the metallic object, with
respect to the ESD-sensitive device, can still result in
ESD damage or EMI.
R2-3.5 To prevent these conditions from occurring, the
proper resistance for the ground path should be chosen.
A class of materials has been developed, called static
dissipative materials, which help to control discharge
rates when materials are placed in contact. Static
dissipative materials are created by lowering the
resistivity of insulating materials through the addition
of conductive particles, carbon particles, or chemical
additives. When connected to ground, these materials
slow the discharge rate from nanoseconds (typical for
metal-to-metal contact) to as long as hundreds of
milliseconds (depending on the size of the materials
involved). While a discharge occurs to allow charge
equalization with ground, a rapid, spark-producing
discharge may not occur.
R2-3.6 In modern production equipment, the frame and
other machine elements are normally metallic and thus
conductive. These machine elements are often covered
with static dissipative materials. In these design
situations, the conductive frame should be attached to
ground without any added resistance to provide a
ground plane. The dissipative surface over the
conductive frame provides charge-draining
characteristics suitable for reducing risk of damage
from rapid discharges.
R2-3.7 Static dissipative materials will need to retain
their dissipative properties over the range of
temperature and humidity conditions they will
encounter, and not change significantly over time. In
cleanrooms they should also meet requirements for
avoiding micro-particle production and outgassing.
R2-3.8 Measurements of the resistance and resistivity
of static dissipative materials are used to characterize
their effectiveness in a static control program.
Measurements should be made of the materials
themselves, as well as their performance in their
installation location. There are several measurement
methods available depending on the application.
Acceptable resistance ranges may depend on the ESD
sensitivity of the products or photomasks that are
handled in the area. These will need to be determined
by the end user and the material suppliers.
R2-3.9 See the following test methods for resistance
measurements of various items:
• ESD STM11.11: Surface Resistance Measurement
of Static Dissipative Planar Materials
• ANSI ESD STM11.12: Volume Resistance
Measurement of Static Dissipative Planar Materials
Both test methods characterize the resistivity or
resistance of either static dissipative or conductive
materials. These test methods can be used for
construction materials, work surfaces, furniture
components and most planar surfaces. They may also
be used for packaging and transport materials.
• ANSI ESD S4.1 can be used to measure the
resistance to a groundable point of these materials
once they are in place. This can be done for work
surfaces, construction materials (other than
flooring), and other planar surfaces on furniture or
equipment.

SEMI E129-1103 © SEMI 2003 19
• ESD STM7.1 can be used to measure the resistance
to a groundable point and resistance point-to-point
for flooring,
• ANSI ESD STM12.1 can be used to measure the
resistance to a groundable point for components of
chairs.
• Resistance characteristics of the wrist straps used
to ground personnel are covered in ANSI ESD
S1.1.
• Cleanroom garments may be tested with the
methods of ANSI ESD STM2.1.
R2-4 Static Charge Decay Time
R2-4.1 In some cases, it will be important to know the
actual time it takes to remove a known amount of
charge from an object.
• FED-STD-101 Method 4046 is often used for
homogeneous materials.
• ANSI ESD STM4.2 is used to measure decay time
of worksurface materials.
R2-4.2 Please be aware that static decay time may not
fully characterize an item or a material. However, the
information gathered in a decay time test may provide
valuable insight into the electrostatic performance of an
item or material when used in conjunction with other
data such as resistance or resistivity. Decay time is
only useful for materials with a high
resistance/resistivity. For materials with resistance less
than 10
10
Ω, decay time does not apply because the
equipment used is unable to measure decay times faster
than 0.01 s.
R2-5 Measuring Static Charge Levels on
Personnel
R2-5.1 Since personnel are mobile electrical
conductors, they pose a significant hazard in any ESD-
susceptible workplace. Thus, grounding of personnel is
among the most important of all static control technical
requirements. All of the industry program management
standards accepted around the world require grounding
of personnel as a foremost requirement. The most
important consideration for personnel in a properly
designed electrostatic protective area (EPA) is to
maintain the resistance to ground at < 35 MΩ for
operations handling parts sensitive to above 100-V
Human Body Model sensitivity. For areas handling
parts susceptible to less than 100-V HBM, the
resistance-to-ground specification should be reduced to
less than 10 MΩ to ground. Testing by the ESD
Association has shown that at 35 MΩ to ground, a
person can generate up to 100 V by vigorous movement
such as sliding feet on the floor. At 10 MΩ to ground,
the maximum voltage potential drops to about 6 V, a
level that is highly unlikely to contribute to damaging
even the most sensitive parts (consider the resistance
discussion above). Standard wrist strap test methods
are described and defined in ANSI ESD S1.1.
R2-5.2 For high-risk applications, advanced testing of
personnel grounding systems may be required. A
modern concept for continuous verification of
personnel grounding includes wrist strap constant
monitor systems. Choosing an appropriate system of
constant monitoring requires an understanding of the
actual performance measurement. To verify personnel
grounding, it is important to measure the condition of
the total system including the interaction of all the
contact resistances, together with wrist strap bands and
skin as well as ground cord, and shoes or shoe straps
with skin or stocking moisture. Make sure all
measurements include all the resistive interconnections
of the grounding systems. Do not do system
measurements without including all the components
and personnel.
R2-5.3 A common grounding appliance for personnel
is a wrist strap and connecting ground cord attached to
a common point grounding terminal at a workstation.
Since this methodology is most suitable for seated
personnel, it is a stated requirement in all of the
recognized static control programs (i.e., ANSI ESD
S20.20, JEDEC JESD625, IEC 61340-5-1, and EN
61340-5-1 (formerly CENNELEC 100015-1).
R2-5.4 Another common methodology for grounding
mobile personnel is a static control floor with static
control footwear. If this concept is used as the primary
grounding system, the resistance to ground has to be the
same as for a wrist strap. A useful test method for
resistance to ground of personnel through a floor-
footwear system is ANSI ESD STM97.1. An
alternative methodology in ANSI ESD S20.20 where
the resistance to ground of the floor-footwear system is
above 35 MΩ is to measure the voltage of a person
relative to ground using ESD STM97.2. This method
measures the charge generation characteristics of a
person moving about on a floor.
R2-5.5 Clothing coverings using approved static
control materials are often a requirement, especially in
cleanrooms. When ESD issues are involved, garments
need to be tested using approved test methods. A
useful method is ANSI ESD STM2.1.
R2-5.6 Additional static control information, useful
where personnel are concerned, may come from ESD
TR03 for gloves and finger cots, ESD TR05 for
garments, and ESD TR06 for triboelectrically charged
garments.

SEMI E129-1103 © SEMI 2003 20
R2-6 Neutralizing Charge on Insulators
R2-6.1 Static charge on a conductive or static-
dissipative object can be controlled if the object is
provided with a path for the charge to flow to earth
ground. Unfortunately, grounding methods do not
provide complete protection from static-related
problems. Even when earth grounding is an option, it is
subject to human error. In applications where
contamination is an issue, additives and carbon particles
used in static-dissipative materials may become sources
of contamination themselves.
R2-6.2 While charge is mobile in a conductor (or in a
static-dissipative material), in insulators charge is not
mobile, and earth grounding is not an effective means
of eliminating the static charge. More often than not,
the product itself uses insulating materials, making
earth grounding unavailable as an option. While silicon
is a semiconductor, its oxide coating transforms it into
an insulator. Polytetrafluoroethylene (PTFE) is used in
many chemical processes, and quartz in high-
temperature processes. Epoxy and ceramic packages
are used for integrated circuits. Insulators are easily
charged, retain their charge for long periods of time,
and are often close to the product.
R2-6.3 Dealing with static charge on insulators and
isolated conductors will often require the use of some
type of ionization or surface-resistance modification.
Ionizers are the most effective means of dealing with
static charges on insulators and isolated conductors if
the surface cannot be modified by coating or treatment
with some form of surface-dissipative or low-charging
“antistatic” agent.
R2-7 Ionization
R2-7.1 For purposes of static charge control, ions are
molecules of the gases in air (i.e., nitrogen, oxygen,
water vapor, carbon dioxide) that have lost or gained an
electron. Ions are present in normal outside air but are
removed when air is subjected to filtration and air
conditioning. Ionization systems work by increasing
the conductivity of the air by supplying ionized gas
molecules. Another way of looking at the application
of ionization is to interpret the function as supplying
opposite polarity charge from the air to surfaces
charged to the opposite polarity. When ionized air
comes in contact with a charged surface, the charged
surface attracts ions of the opposite polarity. As a
result, the static charge that has built up on products,
equipment and surfaces is neutralized.
R2-7.2 The most common methods of producing air
ions are radioisotopes and “corona discharge” resulting
from the electric field created when high voltage is
applied to a sharp point.
R2-7.3 The radioisotope most commonly used to
produce ionization is polonium-210, an alpha particle
emitter. The alpha particle collides with the
surrounding gas molecules, dislodging electrons. Gas
molecules that lose an electron become positive ions.
The free electron is quickly captured by another neutral
gas molecule, creating a negative air ion. Note that the
process always creates pairs of positive and negative
ions.
R2-7.4 The corona discharge method produces a very
high electric field that interacts with the electrons in the
surrounding gas. The polarity of the ions depends on
the polarity of the high voltage on the emitter point.
Ionizers using the corona discharge method will often
include some type of monitoring and feedback circuitry
to assure that equal numbers of positive and negative
ions are created.
R2-7.5 Ions of opposite polarity to the charged surface
are required. Either polarity of static charge may be
created on facility and equipment surfaces, or on the
product. Ionizers may be installed on the ceiling of the
room or may be hung from the ceiling using appropriate
mounting methods. Ionizers are installed in
minienvironments, particularly in the product load and
unload areas. Ionizers may also be installed in the
interior of process equipment. No single ionizer type or
installation location is sufficient to solve all the static
problems in the semiconductor facility.
R2-7.6 Ionizers should deliver ionization over a wide
range of humidity and temperature conditions. Back-
end assembly and test areas often do not have the level
of temperature and humidity control found in front-end
wafer production. Ionizers installed in the cramped
spaces of production equipment will be close to the
product, in areas surrounded by grounded metal parts.
Ionizers should isolate the emitter points from both the
product and adjacent grounded surfaces. Ionizers
should produce sufficient ions to discharge static on
surfaces and on products moving at high speeds despite
losses to ground. Most ionizers require maintenance
and periodic verification of their performance. The
appropriate ionizer installation will need to be
engineered for each specific application.
R2-8 Packaging Materials
R2-8.1 Types of Packaging
R2-8.1.1 Many forms of flexible and rigid packaging
are used to protect ESD-susceptible items. Bags,
boxes, wraps, tape and reel, pouches, cushioning foams,
totes, tubes and numerous other forms of containers are
available for any imaginable application. Each of these
container forms is available in an ESD-protective
version. Application in cleanroom environments adds