SEMI E108-0301 © SEMI 20011
SEMI E108-0301
TEST METHOD FOR THE ASSESSMENT OF OUTGASSING ORGANIC
CONTAMINATION FROM MINIENVIRONMENTS USING GAS
CHROMATOGRAPHY/MASS SPECTROSCOPY
This test method was technically approved by the Global Metrics Committee and is the direct responsibility
of the European Equipment Automation Committee. Current edition approved by the European Regional
Standards Committee on December 20, 2000. Initially available at www.semi.org February 2001; to be
published March 2001.
1 Purpose
1.1 The purpose of this standard is to define a test
method for the determination of the outgassing organic
contamination from minienvironments used for storage
and transport of wafers using gas chromatography/mass
spectroscopy (GC/MS).
1.2 This test method is intended as an alternative to
SEMI E46. The main difference between SEMI E46
and this document is that SEMI E46 defines a test
method which is based on ion mobility spectroscopy
(IMS) as the measurement technique while this
standard is based on gas chromatography/mass
spectroscopy in combination with thermal desorption.
Additionally, this test method provides a procedure for
testing the outgassing of organic compounds in a
complete minienvironment. The results of SEMI E46
and this document are given in different units.
2 Scope
2.1 The test method provided in th is document is
applicable to the assessment of the outgassing of
organic contamination from minienvironments.
2.2 Gas chromatography/mass spe ctroscopy is chosen
as the method to determine organic contamination
because it is commonly used for characterization and
quantification of organic compounds. In combination
with thermal desorption, it provides a method for the
identification of organic compounds in the atmosphere
(i.e., inside the minienvironment) as well as directly
from source materials, and transferred contaminants.
This method can also be used to evaluate materials and
processes used in semiconductor industry.
2.3 This test method is based on ASTM F1982.
2.4 This standard does not purport to address safety
issues, if any, associated with its use. It is the
responsibility of the users of this standard to establish
appropriate safety health practices and determine the
applicability or regulatory limitations prior to use.
3 Limitations
3.1 The test methodologies, metric s and applications
provided in this standard are limited by the following
constraints:
3.1.1 The specific recovery of comp ounds by the
proposed standard method strongly depends on the
setup of the apparatus used. This has been taken into
account by the use of the “reference-cocktail”, see
Section 9.2.
3.2 Identification of the source of organic compounds
inside the minienvironment is out of the scope of this
test method. For a procedure for the analysis of
outgassing organic compounds from individual
materials using gas chromatography/mass spectroscopy,
see IDEMA M11-99.
3.3 This test method does not prov ide a procedure how
to use the obtained data for assessing the risks that
come from individual compounds.
4 Referenced Standards
4.1 SEMI Standards
SEMI E46 — Test Method for the Determination of
Organic Contamination from Minienvironments
SEMI F21 — Classification of Airborne Molecular
Contaminant Levels in Clean Environments
4.2 ASTM Standard
1
ASTM F1982 — Standard Test Methods for Analyzing
Organic Contaminants on Silicon Wafer Surfaces by
Thermal Desorption Gas Chromatography.
4.3 IDEMA Standard
2
IDEMA M11-99 — General Outgas Test Procedure by
Dynamic Headspace Analysis
1 American Society for Testing and Materials, 100 Barr Harbor
Drive, West Conshohocken, PA 19428-2959, website: www.astm.org
2 International Disk Drive Equipment and Materials Association,
3255 Scott Blvd., Suite 2-102, Santa Clara, CA 95054-3013, website:
www.idema.org
SEMI E108-0301 © SEMI 2001 2
NOTE 1: As listed or revised, all documents cited shall be the
latest publications of adopted standards.
5 Terminology
5.1 analytical environment environment where all
analytical measurements are taking place.
5.2 headspace sampling — in this standard defined as:
collecting volatile organic compounds in an enclosed
volume by means of a silicon wafer or silicon wafer
chips.
5.3 minienvironment — A localized environment for
transport and storage created by an enclosure to isolate
the product from contamination and people.
5.4 sample — wafer or wafer chip s used for the
headspace sampling of organic contaminants.
5.5 static storage conditions — co nditions excluding
any active movement of test specimens.
5.6 thermal desorption tube — Analytical equipment
capable of collecting organic compounds of interest
(i.e., adsorbent filled glass tube).
5.7 wafer — Object made of semiconducting material
to be processed, handled or stored in the
minienvironment to be tested (i.e., prime or processed
silicon wafer).
6 Summary of Method
6.1 This test method comprises sto rage tests of wafers
in minienvironments under static storage conditions.
The contamination is directly measured from the silicon
wafer surface. Three important aspects are covered:
a) Contamination due to the minienvironment alone,
b) Contamination from the use of minienvironments for
wafer processing, and
c) Contamination from future materials to be used in
semiconductor technology.
6.2 The setup for each test compri ses an analytical
equipment in the analytical environment as well as a
test equipment in the test environment. Each
environment has to fulfill the following requirements:
6.2.1 Analytical Environment — shall be clean enough
with respect to airborne organic contamination:
recommendation is less than 100 pptM for organic
compounds with boiling points > 150°C (Class MC-
100, according to SEMI F21).
6.2.2 Test Environment — shall equ al the environment
in which the test specimen will be used.
6.3 Silicon wafers are placed in the minienvironment
or used for headspace sampling experiments. These
wafer samples are then analyzed by gas chromatogra-
phy/mass spectrometry to determine the amount of
contaminants.
6.4 The wafers or wafer chips to b e used for the test
method are decontaminated as described in ASTM
F1982 for bare silicon wafers. The surface condition of
the wafer (hydrophobic or hydrophilic) has to be
adjusted in a reproducible way and has to be the same
for all comparative measurements.
6.5 The wafer or the wafer chips are placed in the
minienvironment and are left there under static
conditions for the chosen static storage time (depending
on the intended use of the minienvironment to be tested,
a time between 1 h and 28 d may be used). When
loaded into the minienvironment the wafer may have a
temperature which reflects production circumstances
(i.e., 80°C when unloading from furnace processes). In
some situations wafers may be exposed to severe
thermal conditions. The minienvironment should be
evaluated under the conditions exposed to. Be sure that
the material to be tested does not undergo phase
transitions under the chosen temperature conditions.
6.6 After the static storage test per iod, the wafer is
returned to the analytical equipment and the organic
contamination on the wafer is measured immediately.
6.7 The quantitative value for the total amount of
outgassed and adsorbed organics from the minienviron-
ment is calculated as the difference between the
detected amount of contamination on a blank sample
vs. the amount on the exposed sample.
7 Interferences
7.1 The presence of organic conta mination in the
atmosphere of the test environment may lead to a
significant contribution to the detected total amount of
organic compounds on the test wafers or wafer chips.
Care has to be taken when subtracting the blank value
from the test value. Transport times from test
environment to analytical environment have to be as
short as possible.
8 Apparatus
8.1 For the analysis of organic compounds on wafers a
gas chromatography/mass spectroscopy apparatus with
thermal desorption unit is required: A gas
chromatography (GC) instrument, which utilizes a
capillary column to separate a wide variety of organic
compounds, combined with mass spectrometer (MS). A
thermal desorption unit is used to desorb organics from
sample thermal desorption tubes and collect them in a
trap. Two types of trapping may be used:
SEMI E108-0301 © SEMI 20013
a) cooling the trap down to a minimum of -150°C does
not require any adsorbent (glass wool may be used) or
b) a Tenax® filled trap has to be cooled down to a
minimum of -25°C.
8.1.1 The thermal desorption unit is coupled to the gas
chromatography instrument via a heated transfer line.
This apparatus may be used directly for the desorption
from wafer chips which are put in empty glass (or
stainless steel) thermo desorption tubes (method A).
8.1.2 A desorption unit for complete wafers is
specified in ASTM F1982. In this case sample thermal
desorption tubes packed with adsorbent have to be used
to trap compounds desorbed from the wafer. These
thermal desorption tubes are analyzed within the
thermal desorption unit (method B).
8.2 The analysis of outgassing org anic contamination
from minienvironments requires an extremely sensitive
analytical equipment. Recovery and limit of detection
for the different classes of compounds must be
evaluated carefully in order to ensure reliable results.
9 Reagents and Materials
9.1 For the materials used for hand ling and transport
of wafers clean, decontaminated equipment has to be
used, e.g. tweezers heated in a propane flame. Refer to
the reagent and materials described in SEMI E46 and
ASTM F1982.
9.2 Test Mixture — For the calibra tion of equipment
and the quantification of the amount of contamination a
test mixture (”cocktail”) is used. This mixture was
chosen in order to give an ”average” over typical
substance classes present in semiconductor production
lines, which have high sticking factors to the wafer
surface. The response factor of the MS-detection for
organics varies significantly. As this is true for all
contaminants, the method gives a realistic trustworthy
quantitative correlation to a ”typical average compound
mixture” of contaminants on wafer surfaces.
9.3 Preparation of Test Mixture
9.3.1 The mixture consists of triethyl phosphate,
ε-caprolactam, palmitic acid and diethylhexyl phthalate
each 0.5 µg/µl in isooctane (as solvent). The
preparation has to be done according to SEMI E46.
NOTE 2: A similar test mixture is suggested by the working
group WG 031 of the Institute for Environmental Science and
Technology (IEST)
10 Safety Precautions
10.1 All preparation and analytical work has to be
done according to local safety regulations.
11 Preparation of Minienviro nment and
Sample
11.1 Minienvironment — The minie nvironment to be
tested has to be used as received from the supplier. A
cleaning step can be added but there must be no
contribution from the cleaning procedure to the
outgassing of organic compounds from the
minienvironment. The cleaning method has to be
defined by the supplier or agreed upon between supplier
and user of the tested minienvironment.
11.2 Sample — The wafers shall be made organic-free
before using them to monitor organic contamination.
The surface condition of the wafer (hydrophobic or
hydrophilic) has to be adjusted in a reproducible way
and has to be the same for comparative measurements.
Refer to SEMI E46 and ASTM F1982.
12 Procedure
12.1 The procedure described below is used for
obtaining the baseline value of the method (method
blank) as well as the test value for outgassing organic
compounds of the minienvironment within a defined
static storage time (storage time t
S
= 1 h - 28 d).
12.1.1 Choose that static storage time according to the
intended use of the minienvironment (i.e., if the
maximum sit time of wafers in a process where the
minienvironment is to be used is 4 h then choose a
static storage time of 4 h). If no static storage time
related to processes can be defined, a recommended
value for the first static storage time is 1 day.
NOTE 3: Composition of adsorbed compounds may vary with
static storage time.
12.2 For transport store the wafers or wafer chips used
for testing in decontaminated, organic-free petri-dishes
wrapped in organic-free aluminum foil. Refer to SEMI
E46.
12.3 Loading Procedure
12.3.1 For tests at room temperature: open a
minienvironment to be tested and load it with a
decontaminated wafer using decontaminated handling
tools (i.e., tweezers). Default storage location is the
center slot of the minienvironment. Close the
minienvironment. Leave the minienvironment closed
for the chosen static storage time.
12.3.2 For tests at elevated temperatures using a
wafer furnace: place the decontaminated wafers in a
clean furnace used for production processes and heat
the wafers under inert gas to a temperature > 120°C.
Turn off the heating. When the temperature of the
furnace has reached (90±10)°C open the
minienvironment to be tested and fully load it with the