SEMI E54.##-0705 © SEMI 2005 1 SEMI E54.17-0705 SPEC IFICAT ION OF SENSOR /A CTUATOR NETWORK FOR A-LINK This specificatio n was technically approved by the gl obal Information & Contr ol Committee. This edition was a…

100%1 / 7923
SEMI E54.16-0705 © SEMI 2005 46
Table 96 Assembly-EPD#4 Object Instance Network Variables
Assembly-EPD#4
Profile ID = 180.97, Instance ID = 01
Sequence
Number
Name Storage Class SDM Tag Standard NV or CP Data Type
1 Data File A1 LonMark file transfer NVs and messaging
interface.
Table 97 Assembly-EPD#4 Object Instance Network Services
Assembly-EPD#4
Profile ID = 180.97, Instance ID = 01
Service
Request Code
Service Name SDM Tag Request Parameters Result Parameters
-- No Additional Services Defined
NOTICE: SEMI makes no warranties or representations as to the suitability of the standards set forth herein for any
particular application. The determination of the suitability of the standard is solely the responsibility of the user.
Users are cautioned to refer to manufacturer's instructions, product labels, product data sheets, and other relevant
literature, respecting any materials or equipment mentioned herein. These standards are subject to change without
notice.
By publication of this standard, Semiconductor Equipment and Materials International (SEMI) takes no position
respecting the validity of any patent rights or copyrights asserted in connection with any items mentioned in this
standard. Users of this standard are expressly advised that determination of any such patent rights or copyrights, and
the risk of infringement of such rights are entirely their own responsibility.
Copyright by SEMI® (Semiconductor Equipment and Materials
International), 3081 Zanker Road, San Jose, CA 95134. Reproduction of
the contents in whole or in part is forbidden without express written
consent of SEMI.
SEMI E54.##-0705 © SEMI 2005 1
SEMI E54.17-0705
SPECIFICATION OF SENSOR/ACTUATOR NETWORK FOR A-LINK
This specification was technically approved by the global Information & Control Committee. This edition
was approved for publication by the global Audits and Reviews Subcommittee on May 20, 2005. It was
available at www.semi.org in June 2005 and on CD-ROM in July 2005.
1 Purpose
1.1 This document defines a communication specification based on the A-LINK protocol to enable communications
between intelligent devices on a sensor/actuator network (SAN) that operate according to SEMI E54 device models
on semiconductor manufacturing equipment.
1.2 This document gives interoperability with SEMI E54 common/specific device model based Sensor/Actuator
devices.
2 Scope
2.1 This document specifies how Sensor / Actuator / Controller devices interoperate on the network specific for the
A-LINK Public specification referenced in the §4, as a part of equipment’s control system.
2.2 This document defines relation with main part of SEMI E54 including Common Device Model (CDM) and
existing Specific Device Models (SDMs). This document is to be used with the CDM and one or more SDMs, as
well as the A-LINK Public Specification.
NOTICE: This standard does not purport to address safety issues, if any, associated with its use. It is the
responsibility of the users of this standard to establish appropriate safety and health practices and determine the
applicability of regulatory or other limitations prior to use.
3 Limitations
3.1 This document specifies a semiconductor equipment SAN based only A-LINK and is a companion document to
the A-LINK specification; therefore a complete specification of this standard includes the A-LINK specifications.
There are other semiconductor SAN communication options. The specifications for these options are not included
here.
3.2 This standard specifies enhancements that provide additional capability over and above those currently required
by A-LINK. In order to avoid document inconsistency problem, information in the A-LINK specification that relates
to this standard is not repeated in this document. This document is limited to describing enhancements or limitations
to the A-LINK specification that are imposed by this standard.
3.3 A complete specification of the conformance testing procedure shall include the A-LINK protocol conformance
testing specification. Conformance testing shall also include enhancements and limitations to the A-LINK
specification required by this standard.
4 Referenced Standards and Documents
4.1 SEMI Standards
SEMI E39 — Object Services Standard: Concepts, Behavior, and Services
SEMI E54.1 — Standard for Sensor/Actuator Network Common Device Model
SEMI E54.3 — Specification for Sensor/Actuator Network Specific Device Model for Mass Flow Device
SEMI E54.10 — Specification for Sensor/Actuator Network Specific Device Model for an In-situ Particle Monitor
Device
SEMI E54.11 — Specific Device Model for Endpoint Devices
4.2 OSI Standard
ISO 7498 OSI — Basic Reference Model for Open Systems Interconnection
SEMI E54.##-0705 © SEMI 2005 2
4.3 A-LINK Documents
1
A-LINK Public Specification ver. 1.2 — Basic Reference Model for Open Systems Interconnection
NOTICE: Unless otherwise indicated, all documents cited shall be the latest published versions.
5 Terminology
5.1 Abbreviations and Acronyms
5.1.1 AUF — A-LINK User Forum
5.1.2 CDM — Common Device Model
5.1.3 NCS — Network Communication Standard
5.1.4 OSI — Basic Reference Model for Open Systems Interconnection (ISO 7498)
5.1.5 PHY — Physical Layer
5.1.6 SAN — Sensor/Actuator Network
5.1.7 SDM — Specific Device Model
5.1.8 UI — User Interface
5.2 This section includes the terms defined in SEMI E54.1 Sensor/Actuator Network Common Device Model.
5.2.1 Attribute
5.2.2 Behavior
5.2.3 Byte
5.2.4 Class
5.2.5 Common Device Model
5.2.6 Device
5.2.7 Device Manager (DM) Object
5.2.8 Device Model
5.2.9 Instance
5.2.10 Network Communication Standard
5.2.11 Object
5.2.12 Sensor, Actuator and Controller (SAC) Object
5.2.13 Service
5.2.14 Specific Device Model
5.2.15 state diagram
5.3 Terminology Defined in A-LINK
5.3.1 AUF — A-LINK User Forum.
1
A kind of consortium for A-LINK users to recommend improvement to A-
LINK trade organization
2
, share A-LINK applications, provide A-LINK compliance test and etc.
5.3.2 AN MS — a station that accesses and exchanges data by polling its assigned Networked-Slave stations.
5.3.3 AN SS — a station that is managed and accessed by AN MS.
1 http://www.a-linkuf.com
2 http://www.algosystem.co.jp