SEMI S2-0703a
E
© SEMI 1991, 2004 29
24.3.2 Non-defeatable safety interlocks should be
provided on barriers preventing maintenance access to
radiation fields in excess of 10 microsieverts (Sv) or 1
millirem per hour.
24.3.3 Administrative Controls — When
administrative controls (e.g., distance, time, standard
operating procedures, labeling) are to be used, the
equipment supplier should provide detailed
documentation explaining the use of the administrative
controls.
24.4 Equipment utilizing or producing ionizing
radiation should be labeled appropriately.
NOTE 117: Label contents are typically controlled by
regulation in the country in which the equipment is to be used.
24.5 The manufacturer should conduct an assessment
to document conformance to the criteria specified in
Sections 24.2.1 through 24.2.2 during normal
equipment operation, maintenance, and service.
24.5.1 A radiation survey should be used to confirm
design compliance and serve as a baseline survey (see
also Table A4-1 of Appendix 4).
24.5.2 Measurements should be taken using recognized
methods with documented sensitivities and accuracy. A
report documenting the survey methods, equipment
operating parameters, instrumentation used, calibration
data, source locations, results, and discussion should be
made available.
24.5.3 If supplemental administrative controls are
recommended based on survey results or calculations, a
discussion should be provided in the operations and
maintenance manuals describing the source locations,
radiation levels, and recommended control measures.
NOTE 118: Ionizing radiation sources must be registered or
licensed according to the regulations of the country of
destination. These radiation sources must conform to the
regulations of central or local government agencies,
whichever is stricter.
NOTE 119: It is recommended that equipment containing
radioactive materials should demonstrate conformance to
licensing with local regulatory agencies prior to shipment.
NOTE 120: Equipment that uses particle acceleration in its
process has the potential for generating ionizing radiation as a
result of nuclear interactions between the accelerated particles
and various materials. These materials can include materials
of construction of the equipment, accumulated residual
process materials in the equipment, and the target materials.
25 Non-Ionizing Radiation and Fields
25.1 This section covers equipment that produces non-
ionizing radiation, except laser sources, in the following
categories:
static electric and magnetic (0 Hz),
sub-radio frequency electric and magnetic fields
( < 3 kHz),
radio frequency (3 kHz–300 GHz),
infrared radiation (700 nm–1 mm),
visible Light (400 nm–700 nm), and
ultraviolet Light (180–400 nm).
25.2 Potentially hazardous non-ionizing radiation
emissions that are accessible to any personnel should be
limited to the lowest practical level. This criterion can
be met by demonstrating conformance to the following
provisions:
EXCEPTION: Emissions of non-ionizing radiation
exceeding the cardiac pacemaker limits in Appendix 5
but less than the levels in Sections 25.2.1 and 25.2.2
should be identified with appropriate labeling. See also
Section 25.5.1.
25.2.1 Accessible levels of non-ionizing radiation
during normal operations are less than the Operator-
Accessible Limit (see Appendix 5);
25.2.2 Accessible levels of non-ionizing radiation
during maintenance and service procedures are less
than the Maintenance- and Service-Accessible Limit
(see Appendix 5).
25.3 Sources of potentially hazardous non-ionizing
radiation should be identified in the operation and
maintenance manuals, and appropriate parameters
listed. Parameters include frequency, wavelength,
power levels, continuous wave or pulsed (see also
Appendix 5). If pulsed, parameters also include the
pulse repetition rate, pulse duration, and description of
the pulse waveform.
EXCEPTION: Visible sources which are intended to be
viewed or which provide illumination (e.g., display
panels, visible alarm indicators), and are not lasers, do
not need to be identified.
NOTE 121: It is recommended that UV/IR generators that
are part of fire protection test apparatus, and are provided
with the equipment, be considered as possible sources of
potentially hazardous non-ionizing radiation.
25.4 Equipment should be designed to minimize access
or exposure to non-ionizing radiation during normal
operation, maintenance, and service. Potential
exposures should be controlled in the following order of
preference:
25.4.1 engineering controls (e.g., enclosure, shielding,
guarding, grounding, interlocks);
SEMI S2-0703a
E
© SEMI 1991, 2004 30
25.4.2 administrative controls (e.g., written warnings,
standard operating procedures, labeling); and
25.4.3 personal protective equipment.
25.5 Equipment utilizing or producing potentially
hazardous non-ionizing radiation should be labeled.
25.5.1 Hazard warning labels should be provided by
the manufacturer when emission levels are measured
that may impact cardiac pacemakers or magnetizable
prostheses. These warning labels should be located
where the emissions exceed the pacemaker limit. (See
Appendix 5 for pacemaker labeling levels and
references.)
25.6 The manufacturer should conduct an assessment
to document conformance to the criteria specified in
Sections 25.2.1 and 25.2.2. Engineering calculations
may be used as part of this assessment. All
measurements should be taken using recognized
methods with documented sensitivities and accuracy. A
report documenting the survey methods, equipment
operating parameters, instrumentation used, calibration
data, source location(s), and discussion should be
provided. See Appendix 5.
25.6.1 If supplemental administrative controls are
recommended based on survey results or calculations, a
discussion should be provided in the operations and
maintenance manuals describing the source location(s),
radiation levels, and recommended control measures.
25.6.2 Administrative control procedures
recommended for operation, maintenance, or service
activities should be documented in the operations and
maintenance manuals.
26 Lasers
NOTICE: Section 26 below will be withdrawn upon
July 1, 2006 publication and replaced by the new
Section 26 including: figures and tables as shown in
Delayed Revisions Section 1. The EH&S Committee
has voted that implementation of the information is
OPTIONAL before the effective date.
26.1 Equipment should be identified with a laser
product classification based on the laser energy
accessible during operation, per the applicable standard.
NOTE 122: A Class 1 label may be required in some
jurisdictions, but is not currently required in the United States.
26.1.1 The laser energy (or power), wavelength, and
temporal mode (continuous wave or pulsed) should be
identified in the documentation provided to the user.
NOTE 123: The laser product classification for some
equipment will be Class 1 or 2, even though an embedded
laser is of a higher hazard classification.
26.1.1.1 If pulsed, the pulse repetition rate, pulse
duration and description of the pulse waveform should
be identified in the documentation provided to the user.
26.1.1.2 For Class 3b or 4 embedded laser systems, the
above information and the physical location of the laser
sources within the laser product should be identified in
the documentation provided to the user and in the
maintenance manual.
26.1.2 Equipment should not exceed the laser product
classification of Class 2; however, individual lasers
may exceed this classification prior to integration into
the final equipment assembly.
26.2 Equipment, including beam diagnostic or
alignment tools, should be designed to prevent injury
from all lasers during normal operation, and should
minimize risk of injury during maintenance or service.
Potential exposures should be controlled in the
following order of preference:
26.2.1 Engineering controls (e.g., enclosures,
shielding, filters, use of fiber optics to transmit energy,
interlocks).
26.2.2 Temporary enclosures or control measures for
maintenance, service, and non-routine tasks.
26.2.3 Administrative controls (e.g., written warnings,
standard operating procedures, labeling).
26.2.4 Personal protective equipment.
NOTE 124: Temporary enclosures and personal protective
equipment are considered to be administrative controls,
because they require human action to implement.
NOTE 125: Certain classes of laser products are regulated
around the world. Regulations and licensing requirements
may cover activities such as importing, exporting,
distributing, demonstrating, installing, servicing, and using
these laser products.
26.3 The equipment supplier should provide the
following in the operation and maintenance manuals:
a description of laser-related hazards present
during operation, maintenance, or service, and
methods to minimize the hazard;
justification for any procedures that require a laser
controlled area and the dimensions of this hazard
zone;
administrative controls used in maintenance and
service activities; and
a description of necessary personal protective
equipment.
26.4 The following detailed information should be
available for the evaluator:
SEMI S2-0703a
E
© SEMI 1991, 2004 31
justification for when engineering controls are not
feasible to limit exposure during operation or
maintenance tasks, and how administrative controls
provide equivalent protection (see Section 26.2);
and
documentation showing compliance with an
appropriate international laser product safety or
industry standard, or the national standard for
country of use.
27 Sound Pressure Level
27.1 Equipment should be designed to control
exposures to sound pressure levels equal to or greater
than 80 dBA continuous or intermittent sound pressure
level, and 120 dB instantaneous (impulse) sound
pressure level.
NOTE 126: It is recommended that efforts be made to
decrease sound pressure levels as they approach 80 dBA (i.e.,
77 to 80 dBA), due to the additive sound pressure level effects
of multiple pieces of equipment in the same vicinity.
27.2 The order of preference for controlling exposures
is as follows:
27.2.1 Engineering Controls (e.g., source sound
pressure level reduction, absorption, enclosures,
barriers, acoustic dampening) — At a minimum, the
design of the engineering controls should consider the
sound pressure levels and type, the frequency, and the
appropriate control technologies.
27.2.2 Administrative Controls — Acceptable
administrative controls should be limited to
supplemental hazard warning labels and operating
procedures.
NOTE 127: Noise labeling is typically implemented as signs
located in the users facility.
27.3 Sound level surveys should be conducted by the
manufacturer during equipment development for
equipment that may emit hazardous sound pressure
levels.
27.3.1 The survey should be conducted in accordance
with a recognized standard. In addition, the following
test criteria should be applied:
27.3.1.1 The equipment mode of operation during the
sound pressure level tests should simulate as closely as
possible the actual modes and operating positions that
may be experienced by the equipment user.
27.3.1.2 Measurements should be taken in locations
that best simulate actual positions of operators relative
to the equipment. As a general guideline, the
microphone should be traversed 1 meter from the
equipment, 1.2 meters above the ground to simulate
seated operators, 1.5 meters above the ground to
simulate standing operators, and 3.5 meters (or as far as
possible) away from the nearest walls or sound-
reflecting objects. Measurements are taken 360 degrees
around the equipment wherever possible.
Table 2 Sound Pressure Level Test Criteria
NOTE 128: Background level may be subtracted using an
accepted method. If the sound pressure level difference is less
than 3 dBA, the contribution of the source from the
background cannot be adequately distinguished and the
survey results would not be valid for values over 80 dBA.
Difference between sound
pressure level measured
with noise source operating
and background sound
pressure level (dBA)
Correction to be subtracted
from the sound pressure
level measured with the
noise source operating to
obtain the sound pressure
level due to noise source
alone (dBA)
3 3
4 2.5
5 1.7
6 1.3
7 1
8 0.8
9 0.6
10 0.4
27.3.2 If the measured sound pressure level is less than
70 dBA, the manufacturer should provide to the
evaluator test data documenting sound pressure levels,
survey equipment, equipment calibration, test
conditions and results.
27.3.3 If the measured sound pressure level is greater
than 70 dBA, the test data should include all of the
information in Section 27.3.2, and should also include
the expected duration of personnel exposure.
27.3.4 If measured sound pressure level is greater than
75 dBA, information should be provided in the
equipment maintenance manual describing the sound
pressure level(s) and location(s).
28 Related Documents
28.1 The following documents are sources of
principles and practices of ventilation design.
ACGIH, Hazard Assessment and Control Technology
in Semiconductor Manufacturing, 1989, distributed by
Lewis Publishers, Chelsea, Michigan.
ANSI/AIHA, Standard Z9.5-1992 Laboratory
Ventilation
Burgess, Ellenbecker, Treitman, Ventilation for Control
of the Work Environment, John Wiley, NY, 1989