semi合集-English.pdf - 第2540页
SEMI E88-1104 E © SEMI 1999, 2004 37 STEP COMMENTS HOST SC COMMENTS 24. S6,F11 Event Report Send (ERS) CarrierTransferring · CarrierID = “33333” · CarrierLoc · CarrierZoneName 25. Event Report Acknowledge (ERA) S6,F12 …

SEMI E88-1104
E
© SEMI 1999, 2004 36
STEP COMMENTS HOST SC COMMENTS
S6,F11
Event Report Send (ERS)
ZoneCapacityChange
Event Report Acknowledge (ERA)
S6,F12
7.
S6,F11
Event Report Send (ERS)
CraneActive
8. Event Report Acknowledge (ERA)
S6,F12
9. The Host issues the other two
commands for carriers “22222”
and “33333.”
These commands are queued by
the stocker because it is
active performing the command
for carrier “11111.”
10. Enhanced Remote Command (ERC)
TRANSFER
· COMMANDID = “101883”
· PRIORITY = “21”
· TRANSFERINFO
1. CARRIERID = “22222”
2. SOURCE
3. DEST = “05”
S2,F49
In this scenario SOURCE is the
name of a CarrierLoc or
ZoneName and DEST is the name
of an “loading port.” Either
CARRIERID or SOURCE may be
empty.
11.
S2,F50
Enhanced Remote Command
Acknowledge (ERCA)
12. Enhanced Remote Command (ERC)
TRANSFER
· COMMANDID = “012155”
· PRIORITY = “30”
· TRANSFERINFO
1. CARRIERID = “33333”
2. SOURCE
3. DEST = “05”
S2,F49
In this scenario SOURCE is the
name of a CarrierLoc or
ZoneName and DEST is the name
of an output port. Either
CARRIERID or SOURCE may be
empty.
13.
S2,F50
Enhanced Remote Command
Acknowledge (ERCA)
16. The first carrier is set down
by the stocker on the output
port.
17.
S6,F11
Event Report Send (ERS)
CraneIdle
18. Event Report Acknowledge (ERA)
S6,F12
19.
S6,F11
Event Report Send (ERS)
CarrierWaitOut
· CarrierID = “11111”
· CarrierLoc = “03”
· CarrierZoneName
· PortType = “OP”
20. Event Report Acknowledge (ERA)
S6,F12
21. Now that carrier “11111” has
left the “stocker set down”
position of the output port,
the stocker initiates the next
highest priority queued
command.
22.
S6,F11
Event Report Send (ERS)
TransferInitiated
· CommandID = “012155”
· CarrierID = “33333”
· CarrierLoc
· CarrierZoneName
· Dest = “05”
23. Event Report Acknowledge (ERA)
S6,F12

SEMI E88-1104
E
© SEMI 1999, 2004 37
STEP COMMENTS HOST SC COMMENTS
24.
S6,F11
Event Report Send (ERS)
CarrierTransferring
· CarrierID = “33333”
· CarrierLoc
· CarrierZoneName
25. Event Report Acknowledge (ERA)
S6,F12
S6,F11
Event Report Send (ERS)
ZoneCapacityChange
Event Report Acknowledge (ERA)
S6,F12
26.
S6,F11
Event Report Send (ERS)
CraneActive
27. Event Report Acknowledge (ERA)
S6,F12
28. Carrier “11111” arrives at the
buffer port.
29.
S6,F11
Event Report Send (ERS)
CarrierWaitOut
· CarrierID = “11111”
· CarrierLoc = “04”
· PortType = “BP”
· CarrierZoneName
30. Event Report Acknowledge (ERA)
S6,F12
S6,F11
Event Report Send (ERS)
ZoneCapacityChange
Event Report Acknowledge (ERA)
S6,F12
31. Carrier “11111” arrives at the
first vehicle loading port.
32.
S6,F11
Event Report Send (ERS)
CarrierWaitOut
· CarrierID = “11111”
· CarrierLoc = “05”
· PortType = “LP”
· CarrierZoneName
33. Event Report Acknowledge (ERA)
S6,F12
34. Carrier “11111” can cycle
forward one more port so it
does.
35. Carrier “11111” arrives at the
vehicle loading “end” port
(“06”).
36.
S6,F11
Event Report Send (ERS)
TransferCompleted
· CommandID = “060658”
· ResultCode = 0
· CarrierID = “11111”
· CarrierLoc = “06”
· CarrierZoneName
37. Event Report Acknowledge (ERA)
S6,F12
38.
S6,F11
Event Report Send (ERS)
CarrierWaitOut
· CarrierID = “11111”
· CarrierLoc = “06”
· PortType = “LP”
· CarrierZoneName
39. Event Report Acknowledge (ERA)
S6,F12
40. The stocker sets down carrier
“33333” on the output port.
41.
S6,F11
Event Report Send (ERS)
CraneIdle
42. Event Report Acknowledge (ERA)
S6,F12

SEMI E88-1104
E
© SEMI 1999, 2004 38
STEP COMMENTS HOST SC COMMENTS
43.
S6,F11
Event Report Send (ERS)
CarrierWaitOut
· CarrierID = “33333”
· CarrierLoc = “03”
· CarrierZoneName
· PortType = “OP”
44. Event Report Acknowledge (ERA)
S6,F12
45. Now the stocker can initiate
the next transfer command.
46.
S6,F11
Event Report Send (ERS)
TransferInitiated
· CommandID = “101883”
· CarrierID = “22222”
· CarrierLoc
· CarrierZoneName
· Dest “05”
47. Event Report Acknowledge (ERA)
S6,F12
48.
S6,F11
Event Report Send (ERS)
CarrierTransferring
· CarrierID = “22222”
· CarrierLoc
· CarrierZoneName
49. Event Report Acknowledge (ERA)
S6,F12
S6,F11
Event Report Send (ERS)
ZoneCapacityChange
Event Report Acknowledge (ERA)
S6,F12
50.
S6,F11
Event Report Send (ERS)
CraneActive
51. Event Report Acknowledge (ERA)
S6,F12
52. Carrier “33333” arrives at the
buffer port.
53.
S6,F11
Event Report Send (ERS)
CarrierWaitOut
· CarrierID = “33333”
· CarrierLoc = “04”
· PortType = “BP”
· CarrierZoneName
54. Event Report Acknowledge (ERA)
S6,F12
S6,F11
Event Report Send (ERS)
ZoneCapacityChange
Event Report Acknowledge (ERA)
S6,F12
55. At this point, the
CarrierWaitOut at BP event
could be o
p
tionall
y
used as an
advanced notification to the
Host to
g
o ahead and re
q
uest a
vehicle to come and pick up
carriers “11111” and “33333”.
56. Carrier “33333” arrives at the
first vehicle loading port
(its destination).
57.
S6,F11
Event Report Send (ERS)
TransferCompleted
· CommandID = “012155”
· ResultCode = 0
· CarrierID = “33333”
· CarrierLoc = “05”
· CarrierZoneName
58. Event Report Acknowledge (ERA)
S6,F12