semi合集-English.pdf - 第115页
SEMI E12-0303 © SEMI 1986, 2003 2 generally accepted 0° C, as has the semiconductor industry, i n its defi nition of sc cm. Standard pressure has almost univers ally been accepted as one atmosphere, except for rounding e…

SEMI E12-0303 © SEMI 1986, 2003 1
SEMI E12-0303
STANDARD FOR STANDARD PRESSURE, TEMPERATURE, DENSITY,
AND FLOW UNITS USED IN MASS FLOW METERS AND MASS FLOW
CONTROLLERS
This standard was technically approved by the Global Gases Committee and is the direct responsibility of the
North American Gases Committee. Current edition approved by the North American Regional Standards
Committee on October 25, 2002. Initially available at www.semi.org December 2002; to be published March
2003. Originally published in 1986, previously published in 1996.
1 Purpose
1.1 In the past, confusion has existed in the values of
standard temperature and standard pressure when gas
flow is expressed in “standard” volumetric units. To
eliminate this confusion, the Mass Flow Controllers
Committee has established this standard.
2 Scope
2.1 This standard provides a common basis for
communication between manufacturers and users.
NOTICE: This standard does not purport to address
safety issues, if any, associated with its use. It is the
responsibility of the users of this standard to establish
appropriate safety and health practices and determine
the applicability of regulatory or other limitations prior
to use.
3 Referenced Standard
3.1 ASTM Standard
1
E 380-89a — Standard Practice for Use of the
International System of Units (the Modernized Metric
System)
NOTICE: Unless otherwise indicated, all documents
cited shall be the latest published versions.
4 Terminology
None.
5 Standard Temperature
5.1 Standard temperature is defined as 273.15 K
(0.0° C).
1 American Society for Testing and Materials, 100 Barr Harbor
Drive, West Conshohocken, Pennsylvania 19428-2959, USA.
Telephone: 610.832.9585, Fax: 610.832.9555 Website:
www.astm.org
6 Standard Pressure
6.1 Standard pressure is defined as 101,325 pascals (1
atm, 760 Torr).
7 Standard Density
7.1 The standard density is defined as Mw/22,413.6
grams per standard cubic centimeter (g/scc), where Mw
is the molecular weight of the gas in grams per mole
(g/mol), and 22,413.6 is the standard molar volume in
cubic centimeters (scc/mol) (i.e., the volume of one
mole of a perfect gas at standard temperature and
standard pressure).
8 Standard Flow Rate
8.1 Standard flow rate is the volumetric flow rate of the
gas at the standard density defined in Section 7.1.
9 Units
9.1 Units for standard flow rate may be expressed as
standard cubic centimeters per minute (sccm), standard
liters per minute (slm), standard cubic decimeters per
minute (scdm), or as standard cubic meters per minute
(scmm).
1 sccm = 1 × 10
-3
* slm
= 1 × 10
-3
* scdm
= 1 × 10
-6
* scmm
NOTE 1: Units in this document have been editorially
changed to sccm, slm, scdm, and scmm in line with
international standards which require all units to be expressed
in SI terms. While neither “minute” nor “liter” is a primary SI
unit, each is acceptable under the system, and eliminating the
use of these units in this standard would seriously diminish its
acceptability.
10 Background
10.1 In the absence of this specification, there has been
confusion in the definition of standard conditions.
“Standard” temperature in particular has been variously
defined as 59° F, 68° F, 70° F, 20° C, 22° C, etc. to reflect
“normal” test conditions. The scientific community has

SEMI E12-0303 © SEMI 1986, 2003 2
generally accepted 0° C, as has the semiconductor
industry, in its definition of sccm. Standard pressure has
almost universally been accepted as one atmosphere,
except for rounding errors in different units.
10.2 Further confusion has existed in the definition of
standard density when extended to vapors. For perfect
gases (most light gases are nearly perfect), the standard
density can be defined as the density of the gas at
standard temperature and pressure. Since one gram
mole of a perfect gas occupies 22,414 cubic centimeters
at standard pressure and standard temperature, it
follows that a flow rate of 22,414 sccm of any perfect
gas is one mole per minute.
10.3 By defining standard density as in Section 7.1, the
correlation between sccm and moles/minute is retained,
even for vapors. If standard density were defined as the
actual density of the vapor at standard temperature and
pressure, then the correlation with moles per minute
would differ by the vapor' s compressibility factor (Z).
This is not an acceptable alternative because the
compressibility of many vapors is not accurately
known, and, in fact, does not exist for those materials
that are liquid at standard temperature and pressure.
11 Implications for Calibration
11.1 Since the standard flow units are defined at a
standard density, they represent units of mass flow
rather than volumetric flow.
11.2 Gravimetric calibration readings in grams per
minute (g/min) can be converted to standard cubic
centimeters per minute (sccm) by dividing by the
standard density (g/scc) as defined in Section 7.1.
11.3 Rate-of-rise (ROR) data will generally have
negligible compressibility error when operated over a
low absolute pressure range. If compressibility errors
are significant, they will cause the rate of pressure rise
to be reduced and become pressure-dependent as the
pressure increases. In this case, the pressure range must
be reduced, or correction made, for compressibility.
11.4 Volumetric flow data must be corrected from
actual density of the real gas at the test conditions to the
standard density. The actual density can be
approximated for near-perfect gases by ratios of
absolute pressure and temperature to the standard
density. For vapors, the actual density at the test
conditions must be known from other data.
NOTICE: SEMI makes no warranties or
representations as to the suitability of the standards set
forth herein for any particular application. The
determination of the suitability of the standard is solely
the responsibility of the user. Users are cautioned to
refer to manufacturer’s instructions, product labels,
product data sheets, and other relevant literature
respecting any materials mentioned herein. These
standards are subject to change without notice.
The user’s attention is called to the possibility that
compliance with this standard may require use of
copyrighted material or of an invention covered by
patent rights. By publication of this standard, SEMI
takes no position respecting the validity of any patent
rights or copyrights asserted in connection with any
item mentioned in this standard. Users of this standard
are expressly advised that determination of any such
patent rights or copyrights, and the risk of infringement
of such rights, are entirely their own responsibility.
Copyright by SEMI® (Semiconductor Equipment and Materials
International), 3081 Zanker Road, San Jose, CA 95134. Reproduction o
f
the contents in whole or in part is forbidden without express written
consent of SEMI.

SEMI E15-0698
E2
© SEMI 1990, 2003 1
SEMI E15-0698
E2
(Reapproved 0703)
SPECIFICATION FOR TOOL LOAD PORT
This standard was technically reapproved by the Global Physical Insterfaces & Carriers Committee and is the
direct responsibility of the North American Physical Interfaces & Carriers Committee. Current edition
approved by the North American Regional Standards Committee on March 12, 2003. Initially available at
www.semi.org May 2003; to be published July 2003. Originally published in 1990; previously published
March 2003.
E
This specification was editorially modified in November 2004 to correct an editorial error. Changes were
made to Table 1.
1 Purpose
1.1 This standard is intended to unify the interface
between process/inspection tools and automated wafer
carrier transport systems while maintaining
compatibility with human transport.
2 Scope
2.1 This specification deals with the mechanical
interface (load port) for wafer carrier transfer between
wafer carrier material transport systems, including
humans, and wafer fabrication/inspection equipment
(tools). The concept defines the placement and
orientation of a wafer carrier on a tool to allow
reasonable interfacing with mechanized material
movement systems without compromising human
access to perform the material exchange function.
NOTICE: This standard does not purport to address
safety issues, if any, associated with its use. It is the
responsibility of the users of this standard to establish
appropriate safety and health practices and determine
the applicability of regulatory or other limitations prior
to use.
3 Impact
3.1 Compliance with this specification requires the
placement of load ports on tools to specific heights,
orientations, and load depths. Restrictions are also
placed on clearances to obstructions which may be
adjacent to such ports.
4 Referenced Standards
4.1 SEMI Standards
SEMI E1 — Specification for 3 inch, 100 mm, 125
mm, and 150 mm Plastic and Metal Wafer Carriers
SEMI E19 — Standard Mechanical Interface (SMIF)
NOTICE: Unless otherwise indicated, all documents
cited shall be the latest published versions.
5 Terminology
5.1 Definitions
5.1.1 box — A protective portable carrier for a cassette
and/or substrate(s).
5.1.2 cassette — An open structure that holds one or
more substrates.
5.1.3 cassette centroid — A datum representing the
theoretical center of a stack of wafers in a cassette
formed by the pocket centerline and the “center” pocket
as defined by the location associated with dividing
dimension B3 by two (see SEMI E1, Figure 1).
5.1.4 cassette envelope — A rectangular volume with
vertical sides which completely contains a cassette,
even if the cassette is tilted (see Figure 1).
5.1.5 enclosed load port — A load port with overhead
clearance obstructed by the tool.
5.1.6 global orientation — The general orientation of a
wafer carrier in a tool; may be vertical or horizontal.
5.1.7 load depth — The horizontal distance from the
load face plane to cassette centroid or carrier centroid
(see Figures 2 and 3 (D)).
5.1.8 load face plane — The furthest physical vertical
boundary plane from cassette centroid or carrier
centroid on the side (or sides) of the tool where loading
of the tool is intended (see Figures 2 and 3).
5.1.9
load height — The distance from the bottom of
the cassette or carrier to the floor at the load face plane
(see Figure 3 (H)).
5.1.10 load port — The interface location on a tool
where wafer carriers are delivered. It is possible that
wafers are not removed from, or inserted into, the
carrier at this location.
5.1.11 open load port — A load port with overhead
clearance unobstructed by the tool.
5.1.12 pod — A box having a Standard Mechanical
Interface (SMIF) per SEMI E19.