SEMI C2-95 © SEMI 1981 , 1996 1 SEMI C2-9 5 SPECIFICA TIONS FOR ETCHANTS 1 Preface 1.1 The SEMI Com mittee on Chem i c a l Reagents began its efforts on etchants i n 1979. With t his publication, the Committee estab lish…

SEMI C1-0705 © SEMI 1978, 2005 27
NOTICE: SEMI makes no warranties or representations as to the suitability of the standards set forth herein for any
particular application. The determination of the suitability of the standard is solely the responsibility of the user.
Users are cautioned to refer to manufacturer's instructions, product labels, product data sheets, and other relevant
literature, respecting any materials or equipment mentioned herein. These standards are subject to change without
notice.
By publication of this standard, Semiconductor Equipment and Materials International (SEMI) takes no position
respecting the validity of any patent rights or copyrights asserted in connection with any items mentioned in this
standard. Users of this standard are expressly advised that determination of any such patent rights or copyrights, and
the risk of infringement of such rights are entirely their own responsibility.
Copyright by SEMI® (Semiconductor Equipment and Materials
International), 3081 Zanker Road, San Jose, CA 95134. Reproduction of
the contents in whole or in part is forbidden without express written
consent of SEMI.

SEMI C2-95 © SEMI 1981, 19961
SEMI C2-95
SPECIFICATIONS FOR ETCHANTS
1 Preface
1.1 The SEMI Committee on Chem ical Reagents
began its efforts on etchants in 1979. With this
publication, the Committee establishes definitions for
three major types of etchant mixtures; mixed acid
etchants, buffer oxide etchants, and phosphoric
etchants. Specifications and analytical procedures are
introduced for each type.
1.2 Etchants within all of the requirements can be
described as “meeting SEMI specifications.”
1.3 Where an analytical procedure different from that
provided is substituted by a supplier or user, the burden
of proof is on said supplier or user to confirm the
equivalency.
2 Definitions
2.1 All definitions set forth in SEM I C1, Section 2 are
adopted for SEMI C2.
2.2 Etchant — The exact definitio n of an etchant
mixture shall be set forth as the initial paragraph of its
Standard. The composition shall be expressed as a ratio
of the relative volumes taken of the components in an
assigned order. In the expression, all the relative
volumes shall be reduced to a ratio of the smallest
whole numbers. If a component is absent, its relative
volume shall be taken as zero.
2.3 Composition — The content o f each component of
an etchant shall be expressed on a weight/weight basis
of the 100% component (for example, 100% HF, not
49% HF). Any tolerance allowed for the content of a
component shall be expressed on a weight/weight basis
of that 100% component.
3 General Procedures and G uidelines to
Certain Methods
3.1 The general procedures and guidelines for certain
methods set forth in SEMI C1, Section 3 are adopted
for SEMI C2.
3.2 Determination of Nitric Acid b y Ultraviolet
Absorption Spectrophotometry
3.2.1 Introduction — The photometric determination
of nitric acid in various etchant mixtures is based on the
strong absorption of the nitrate ion in the ultraviolet
region. For this spectral region fused silica (quartz)
cells are required.
3.2.2 Preparation of Calibration Curve — Secure a
bottle of nitric acid (70%) and determine its assay in
duplicate. Accurately weigh 2.8 to 3.0 g dilute with 100
mL of water, add 10 drops of phenolphthalein indicator
solution to each solution, and titrate with standardized 1
N sodium hydroxide solution to a pink end-point.
(g) Sample ofWeight
6.302NaOH of mL
)( Acid Nitric %
w
w
××
=
N
If the results do not differ by more than 0.2%, average
them. Otherwise, repeat the analysis.
3.2.3 In five previously tared weigh ing bottles,
accurately weigh about 1.0, 1.2, 1.4, 1.6 and 1.8 g of
the previously assayed 70% nitric acid. Calculate the
weight, in grams, of 100% nitric acid present in each of
these five standards. Quantitatively transfer each
standard to a separate 100 mL volumetric flask, dilute
to volume with water, and mix thoroughly.
3.2.4 Following the manufacturer’s directions, ready a
spectrophotometer and set the wavelength to 302 nm.
Measure the absorbance of each standard versus water
using a 1 cm fused silica cell. On (linear) coordinate
graph paper plot the absorbance versus the weight, in
grams, of 100% nitric acid for each standard. Draw the
best-fitting straight line through the points.
3.2.5 Application to Acid Etch Mixtu res — Proceed as
given under the Standard for the relevant etchant.
4 Reagent and Standard So lutions
4.1 The reagent and standard solutions set forth in
SEMI C1, Section 4 are adopted for SEMI C2.
4.2 Acetate Buffer for Hydrofluoric Acid
Determination — Dissolve 106 g of sodium acetate
trihydrate, CH
3
COONa•3H
2
O, and 137 g of ammonium
acetate, CH
3
COOHN
4
, in about 700 mL of water. Add
5.1 mL of glacial acetic acid, adjust to pH 5.5-6.6 with
dilute ammonium hydroxide (10% NH
3
) or dilute acetic
acid (20%), and dilute to 1000 mL with water.
4.3 Aluminum Chloride Standard Solution
Preparation — Dissolve 40.0 g of aluminum chloride
hexahydrate, AlCl
3
•6H
2
O, in about 700 mL of water
and 0.5 mL of hydrochloric acid contained in a 1000
mL volumetric flask; dilute to volume with water, and
mix thoroughly.
4.3.1 Standardization — Transfer 1.5 mL of hydro-
fluoric acid to a 250 mL polyethylene beaker containing
50 mL of water. Add 10 drops of phenolphthalein
indicator solution. With magnetic stirring, titrate with
standarized 1N sodium hydroxide solution to a pink

SEMI C2-95 © SEMI 1981, 1996 2
endpoint. Record the volume of base delivered (A).
Add 25 mL of Acetate Buffer for Hydrofluoric Acid
Determination and 1 g of Eriochrome Cyanine R
indicator mixture; mix thoroughly. With magnetic
stirring, titrate with the aluminum chloride solution to a
pink-purple endpoint. Record the volume of this
solution delivered (B).
soln. AlCl of B
2.001NaOH of A
Factor HF
3
××
=
N
4.4 Eriochrome Cyanine A Indicat or Mixture — Using
a mortar and pestle, thoroughly grind and mix 0.1 g of
Eriochrome Cyanine R (C.I. 43820) with 100 g of
potassium nitrate.
5 Safety
Because of the continuing evolution of safety
precautions, it is impossible in this publication to
provide definite statements relating to the safe handling
of individual etchants. The user is referred to product
labels, product and safety data sheets, government
regulations, and other relevant literature.
NOTICE: These standards do not purport to address
safety issues, if any, associated with their use. It is the
responsibility of the user of these standards to establish
appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
SEMI makes no warranties or representations as to the
suitability of the standards set forth herein for any
particular application. The determination of the
suitability of the standard is solely the responsibility of
the user. Users are cautioned to refer to manufacturer’s
instructions, product labels, product data sheets, and
other relevant literature respecting any materials
mentioned herein. These standards are subject to
change without notice.
The user’s attention is called to the possibility that
compliance with this standard may require use of
copyrighted material or of an invention covered by
patent rights. By publication of this standard, SEMI
takes no position respecting the validity of any patent
rights or copyrights asserted in connection with any
item mentioned in this standard. Users of this standard
are expressly advised that determination of any such
patent rights or copyrights, and the risk of infringement
of such rights, are entirely their own responsibility.