SEMI M49-0704 © SEMI 2001, 2004 6 7.2 Other Docume nts Evaluating Automated Wafer Measurement Instruments , SEMATECH 6 , Technology Transfer 941 12638A-XFR Metrology Tool Gauge Study Procedure f or th e International 300…

SEMI M49-0704 © SEMI 2001, 2004
5
6.5.10 In addition two levels of systematic off-set
between different tools are defined:
6.5.10.1 matching tolerance (difference of means ∆
m
)
6.5.10.2 correlation (regression curve)
6.5.11 Explicitly specified in the present document are
only level 3 variability σ
3
and matching tolerance ∆
m
as
they correspond to the utilization of measurement
equipment for wafer manufacturing most closely. The
supplier of a specific tool may optionally provide
specifications for level 1 and/or level 2 variability,
respectively.
6.5.12 Level 3 variability σ
3
and matching tolerance ∆
m
are specified with respect to anticipated specifications
for wafer geometry and flatness as given in Table 3 for
a reference wafer.
6.5.13 In the present document P/T-ratios are used for
specifying level 3 variability σ
3.
6.5.13.1 A precision-to-tolerance ration P/T less than
10% at 6σ is recommended in SEMI M27 for
metrology equipment. This would be an extremely
demanding specification for flatness and geometry
measurement tools. In addition, flatness characterisitics
of Si wafers are typically described by a single sided
distribution with the median approaching zero, the
lower specification boundary. Therefore two grades that
are based on 3σ criteria, instead on 6σ, are
recommended for such tools in the present document:
• grade A: P/T < 10%, 3σ
3
• grade B: P/T < 20%, 3σ
3
6.5.13.2 The individual measurement features a tool
provides may be graded differently, e.g. SFQR might
meet grade A, but SBIR only grade B. This has to be
indicated appropriately in the tools’ technical
specifications.
6.5.14 Matching tolerance is specified to be less or
equal to 1.5σ
3
of level 3 variability. This corresponds to
a greater than 99% probability that the difference of any
individual measurement results obtained with two
different tools is smaller or equal to 5σ
3
.
6.5.15 The target for bias is a range of ± 1.5σ
3
with
respect to a certified value provided appropriate
reference materials are available. This corresponds to a
greater than 99% probability that any individual
measurement is in the range of ± 4σ
3
around the
certified value when a reference material is tested.
6.5.16 Reference material with a series of surface
features with appropriate height and half width is
required to verify bandwidth of a measurement tool.
The height of the features corresponds to the wafer
specification as outlined in Table 3.
6.5.17 The specifications of the measurement
equipment are verified by using wafers the parameters
of which are in a range, the upper limit of which
corresponds to 1.5 times anticipated wafer
specification, the lower limit to 0.5 of anticipated wafer
specification. These are listed in Table 3 as Reference
Wafer Specifications.
NOTE 5: The edge region of wafers represents the most
challenging area for meeting the desired performance
characteristics. This is because of the larger surface geometry
variations in the region near the edge, e.g. from polishing roll-
off.
6.5.18 Reference Wafers — The specifications of the
measurement equipment are verified by using reference
wafers with properties covering the range given in
Section 1 of Table 3. All reference wafers shall meet
the thickness and warp requirements listed in the table
but different wafers may be used to meet the flatness
and nanotopography requirements. For site related
specifications not all sites must fall within the range,
but the appropriate sites to be tested should be
indicated. In all cases, at least three wafers in the range
of values for each property shall be employed in the
testing.
6.5.19 Verification of bias, matching tolerance and the
various levels of variability are performed with
equipment which is calibrated according to the
supplier's procedures and which is under statistical
process control.
6.5.20 Compatibility of two tools is considered to be
satisfactory when the specifications of the older tool are
met with the newer tool operating in the emulation
mode.
6.5.21 The quality of a correlation between different
measurement equipment is not specified in the present
document.
7 Related Documents
7.1 ASTM Documents
E 177 — Standard Practice for Use of the Terms
Precision and Bias in ASTM Test Methods
E 456 — Standard Terminology for Relating to Quality
and Statistics

SEMI M49-0704 © SEMI 2001, 2004 6
7.2 Other Documents
Evaluating Automated Wafer Measurement Instruments, SEMATECH
6
, Technology Transfer 94112638A-XFR
Metrology Tool Gauge Study Procedure for the International 300 mm Initiative (I300I), International 300 mm
Initiative
6
, Technology Transfer #97063295A-XFR
International Technology Roadmap for Semiconductors: 1999 edition
7
,
8
ISO 3274: 1996 — Geometrical Product Specifications (GPS) – Surface Texture: Profile method – Nominal
characteristic of contact (stylus) instruments
1
Table 1 Generic Equipment Characteristics
Item Recommended Specification Comment References
1 WAFER HANDLING
1.1 Robot End-Effector optional wafer edge or backside contact edge as defined
by SEMI M1
1.2 Scan Stage optional wafer edge or backside contact edge as defined
by SEMI M1
1.3 Wafer Contact Materials contact materials to leave metals and
organics on wafers < as defined in ITRS 99
1.4 Wafer Detection protection of accidental contact due to e.g.,
cross-slotting double slotting, protrusions,
etc.
1.5 Wafer Rotational Alignment random in, aligned out
1.6 Number of Cassette Stations 2–4, arbitrary sender/receiver assignment
1.7 Type of Cassettes open, FOUP/SMIF, FOSB to be specified
alternatively
1.8 Cassette Loading manual/guided vehicle, conveyor belt
1.9 Automatic Cassette ID user specific
1.10 Wafer Seating vertical or off-horizontal during setting
cassette on
station by
operator
1.11 Cassette Filling Modes random access and loading, programmable
empty slot filling
1.12 Automatic Wafer ID
reading
user specific
1.13 Particulate Contamination < 0.001 PWP per cm
2
, > 90 nm LSE front,
and > 120 nm LSE backside (See NOTE 1.)
verify with
mirror polished
wafer surfaces
SEMI E14
2 RELIABILITY
2.1 MTBF > 2000 h SEMI E10
2.2 MTTA > 4 h SEMI E10
2.3 MTTR according to service contract SEMI E10
2.4 Availability > 98% per year
2.5 Uptime > 160 h/w
2.6 Response Time according to service contract
2.7 Statistical Process Control
(SPC) performance
automated
6 International Sematech, 2706 Montopolis Drive, Austin, Tx. 78741-6499, USA
7 SEMATECH, 3101 Industrial Terrace Suite 106, Austin TX 78758
8 More recent versions of the ITRS are available from the homepage of International Sematech: www.sematech.org

SEMI M49-0704 © SEMI 2001, 2004
7
Item Recommended Specification Comment References
2.8 Statistical Process Control
(SPC) machine parameters
automated
3 PROCEDURAL
3.1 Acceptance Testing user specific
3.2 Transport and Assembly user specific
3.3 Quality Assurance supplier conforming with ISO 9000/9001 ISO 9000/9001
3.4 Warranty > 1 y
3.5 Test Certificates user specific
3.6 Spares Availability > 10 y
3.7 Change Control supplier conforming with ISO 9000/9001 ISO 9000/9001
4 DOCUMENTATION
4.1 Installation tbd
4.2 Operation tbd
4.3 Service tbd
5 COMPUTER, USER INTERFACE, CONNECTIVITY
5.1 Computer Operating System - Microsoft Windows NT 4.0 or higher, or
- Unix
5.2 Display cleanroom compatible, class 10 (Federal
Standard) or class 4 (ISO), respectively
FED-STD 209E
ISO 14644-1
5.3 Keyboard cleanroom compatible, class 10 (Federal
Standard) or class 4 (ISO), respectively
FED-STD 209E
ISO 14644-1
5.4 Pointing Device cleanroom compatible, class 10 (Federal
Standard) or class 4 (ISO), respectively
FED-STD 209E
ISO 14644-1
5.5 Printer cleanroom compatible, class 10 (Federal
Standard) or class 4 (ISO), respectively
FED-STD 209E
ISO 14644-1
5.6 Data Processing - reprocessing of data
- parallel processing in different modes
during measurement including sorting
- multiprocessing: e.g. recipe editing,
up/downloading during measurements
different modes
refer to data
evaluation e.g.
for two
different site
patterns, or
different
emulation
modes
5.7 Data Access - access to basic measurement results: e.g
thickness map, height map
- data available at SECS/GEM/HSMS
interface in real time
refers to all
functions as
defined in
Table 3
SEMI E5
SEMI E30
SEMI E37
5.8 Data Analysis
(Online/Offline)
on-line/off-line
5.9 Recipe Control - complete recipe generation off-line without
machine specific data (calibration curves)
- off-line recipe editing
- remote recipe control by host computer
- recipes are compatible between different
software versions