SEMI E54.16-0705 © SEMI 2005 25 Table 26 Actuator-BO Object Instance Netw ork Services Actuator-BO Object (Abo) Profile ID = 180.33, Instance ID = 01 through p Service Request Code Service Name CDM Tag Request Parameters…

100%1 / 7923
SEMI E54.16-0705 © SEMI 2005 24
Table 24 Actuator-EO Object Instance Network Services
Actuator-EO Object (Aeo)
Profile ID = 180.34, Instance ID = 01 through o
Service Request
Code
Service Name CDM Tag Request Parameters Result Parameters
1 Reset AeoS1 Actuator-EO Object
RQ_RESET
2 Abort AeoS2 Actuator-EO Object
RQ_ABORT (*)
#1
3 Recover AeoS3 Actuator-EO Object
RQ_RECOVER (*)
#1
6 Operate AeoS4 Actuator-EO Object
RQ_NORMAL
4 GetAttribute AeoS5 Read NV or CP NV or CP Value
5 SetAttribute AeoS6 Actuator-EO Object
RQ_RESTORE (*)
#1
NVO Value
7 RestoreDefault AeoS7 Actuator-EO Object
RQ_PROPAGATE (*)
#1
NVO Value
#1
(*) LonMark interoperability extension. Refer to §6.8.3 for further definition.
7.12.1 Actuator-EO Object Network Variables A new functional profile is defined with the following mandatory
network variables and behaviors. This functional profile forms part of the LONMARK Functional Profiles for SEMI
SAN-compliant devices based on LONWORKS.
7.12.1.1 SNVT_xxx — The setting of the actuator (associated with the object instance) that is to be made available
on the network. The form and content of this SNVT is context-specific.
7.12.2 Actuator-EO Object Configuration Parameters — The Actuator-EO object has configuration properties to
control exception reporting as shown in Table 23. These parameters are Standard Configuration Property Types
(SCPTs). Extensions to the current SCPT list and Interoperability Guidelines are marked by an asterisk (*).
7.13 Actuator-BO Object (Abo) — The presentation of the Actuator Binary Output (Actuator-BO) object instance
attributes are as indicated in Table 25. The presentation of Actuator-BO object services is indicated in Table 26.
Table 25 Actuator-BO Object Instance Network Variables
Actuator-BO Object (Abo)
Profile ID = 180.33, Instance ID = 01 through p
Sequence
Number
Name Storage Class CDM Tag Standard NV or CP Data Type
1 Name CP AboA1 Typedef unsigned char SCPTname (*)
#3
2 Status NVO AboA2 nvoStatus output of the Actuator-BO
Object
3 Alarm Enable NVI AboA3 nviRequest input of the Actuator-BO
Object
4 Warning Enable NVI AboA4 nviRequest input of the Actuator-BO
Object
16 Setting NVI AboA16 Typedef (*)
#3
SNVT_xxx
#2
17 SafeState CP AboA17 Typedef BOOL SCPTsafeState (*)
#3
18 WatchRate CP AboA18 SCPTmaxRcvTime
19 Watchdog CP AboA19 SCPTmaxRcvTime
#1
#1
A value of 0 is used to disable the watchdog timeout.
#2
The form and content of this SNVT is context-specific.
#3
(*) LonMark interoperability extension. Refer to §6.8.3 for further definition.
SEMI E54.16-0705 © SEMI 2005 25
Table 26 Actuator-BO Object Instance Network Services
Actuator-BO Object (Abo)
Profile ID = 180.33, Instance ID = 01 through p
Service Request
Code
Service Name CDM Tag Request Parameters Result Parameters
1 Reset AboS1 Actuator-BO Object
RQ_RESET
2 Abort AboS2 Actuator-BO Object
RQ_ABORT (*)
#1
3 Recover AboS3 Actuator-BO Object
RQ_RECOVER (*)
#1
6 Operate AboS4 Actuator-BO Object
RQ_NORMAL
4 GetAttribute AboS5 Read NV or CP NV or CP Value
5 SetAttribute AboS6 Actuator-BO Object
RQ_RESTORE (*)
#1
NVO Value
7 RestoreDefault AboS7 Actuator-BO Object
RQ_PROPAGATE (*)
#1
NVO Value
#1
(*) LonMark interoperability extension. Refer to §6.8.3 for further definition.
7.13.1 Actuator-BO Object Network Variables A new functional profile is defined with the following mandatory
network variables and behaviors. This functional profile forms part of the LONMARK Functional Profiles for SEMI
SAN-compliant devices based on LONWORKS.
7.13.1.1 SNVT_xxx — The setting of the actuator (associated with the object instance) that is to be made available
on the network. The form and content of this SNVT is context-specific.
7.13.2 Actuator-BO Object Configuration Parameters — The Actuator-BO object has configuration properties to
control exception reporting as shown in Table 25. These parameters are Standard Configuration Property Types
(SCPTs). Extensions to the current SCPT list and Interoperability Guidelines are marked by an asterisk (*).
7.14 Controller Object (C) — The presentation of the Controller Output (C) object instance attributes are as
indicated in Table 27. The presentation of Controller object services is indicated in Table 28.
Table 27 Controller-C Object Instance Network Variables
Controller Object (C)
Profile ID = 180.51, Instance ID = 01 through q
Sequence
Number
Name Storage Class CDM Tag Standard NV or CP Data Type
1 Name CP CA1 Typedef unsigned char SCPTname
(*)
#2
2 Status NVO CA2 nvoStatus output of the Controller
Object
3 Alarm Enable NVI CA3 nviRequest input of the Controller
Object
4 Warning Enable NVI CA4 nviRequest input of the Controller
Object
16 Setpoint CP CA16 Typedef unsigned char SCPTname
(*)
#2
17 ProcessVariable NVI CA17 Typedef (*)
#2
SNVT_xxx
#1
18 ControlVariable NVO CA18 Typedef (*)
#2
SNVT_xxx
#1
19 DataType CP CA19 SCPTnvType
20 DataUnits CP CA20 SCPTnvType
SEMI E54.16-0705 © SEMI 2005 26
Controller Object (C)
Profile ID = 180.51, Instance ID = 01 through q
Sequence
Number
Name Storage Class CDM Tag Standard NV or CP Data Type
21 AlarmSettleTime CP CA21 SCPTalrmSetT2
22 AlarmErrorBand CP CA22 SCPTalrmErrorBand (*)
#2
24 WarningSettleTime CP CA24 SCPTalrmSetT1
25 WarningErrorBand CP CA25 SCPTwarningErrorBand (*)
#2
#1
The form and content of this SNVT is context-specific.
#2
(*) LonMark interoperability extension. Refer to §6.8.3 for further definition.
Table 28 Controller-C Object Instance Network Services
Controller Object (C)
Profile ID = 180.51, Instance ID = 01 through q
Service Request
Code
Service Name CDM Tag Request Parameters Result Parameters
1 Reset CS1 Controller Object
RQ_RESET
2 Abort CS2 Controller Object
RQ_ABORT (*)
#1
3 Recover CS3 Controller Object
RQ_RECOVER (*)
#1
6 Operate CS4 Controller Object
RQ_NORMAL
4 GetAttribute CS5 Read NV or CP NV or CP Value
5 SetAttribute CS6 Controller Object
RQ_RESTORE (*)
#1
NVO Value
7 RestoreDefault CS7 Controller Object
RQ_PROPAGATE (*)
#1
NVO Value
#1
(*) LonMark interoperability extension. Refer to §6.8.3 for further definition.
7.14.1 Controller Object Network Variables A new functional profile is defined with the following mandatory
network variables and behaviors. This functional profile forms part of the LONMARK Functional Profiles for SEMI
SAN-compliant devices based on LONWORKS.
7.14.1.1 SNVT_xxx — The setting of the actuator (associated with the object instance) that is to be made available
on the network. The form and content of this SNVT is context-specific.
7.14.2 Controller Object Configuration Parameters — The Controller object has configuration properties to control
exception reporting as shown in Table 27. These parameters are Standard Configuration Property Types (SCPTs).
Extensions to the current SCPT list and Interoperability Guidelines are marked by an asterisk (*).
8 Protocol Compliance
8.1 A method of testing protocol compliance is required to verify implementation conformance to the standard. By
virtue of the fact that the intermediate layers of the ANSI/EIA/CEA-709.1 (LONWORKS) protocol are implemented
in commercially available silicon, compliance verification is needed only at the physical and application layers. The
LONMARK Interoperability Association provides a compliance verification service to its members. When the SEMI
Sensor/Actuator Network functional profiles are approved and incorporated by LONMARK International Association,
this service may be used to verify compliance with the SEMI guidelines.
8.2 The certification procedure and checklist may be viewed and obtained by accessing web site
http://www.lonmark.org.