SEMI E109-0305 © SEMI 2001, 2005 57 20.2.2 Data required to be available for this ev ent report: BufferPartitionInfo 20.3 Pod Cl osed Event 20.3.1 If the pod is equipped with a door, an e vent shall be genera ted when …

SEMI E109-0305 © SEMI 2001, 2005 56
Parameter Name Req/Ind Rsp/Conf Description
ArrivingReticleList C — The list of reticles to remove from the reticle pod and place in the
equipment. Either ArrivingReticleList or DepartingReticleList must be
used.
DepartingReticleList C — The list of reticle to remove from the equipment and place in the reticle
pod. Either ArrivingReticleList or DepartingReticleList must be used.
RPMStatus — M Information concerning the result of the service.
18.5.20 Unclamp
18.5.20.1 The Unclamp service is used by the host if the equipment has separate mechanisms for unclamping the
carrier that are independent of opening the carrier. It is used to instruct equipment to disengage the independent
clamping mechanism. It is used by the host when “macro” instructions such as provided by Bind, PodNotification,
ProceedWithPod and ReticleTransferJob have not been provided by the host.
Table 55 Unclamp Service Parameter Definitions
Parameter Name Req/Ind Rsp/Conf Description
PodID C — The PodID of the pod to unclamp. Either the PodID or the PortID must
be specified.
PortID C — The PortID for which to unclamp a carrier. Either the PodID or the
PortID must be specified.
CMStatus — M Information concerning the result of the service.
19 Pod Tag Read/Write
19.1 Some technologies allow data to be stored on a PodID tag where it can be subsequently read and/or modified.
In one case the equipment can write information to the PodID tag. For example, the equipment will have knowledge
of the ReticleID of a reticle placed in a pod. At this time the equipment may write the ReticleID on the PodID tag.
In another case, it is the host that specifies when this data is written and read, because the equipment has no
knowledge of the contents of the data. The read operations shall be performed only when the pod is at the read
position. The write operations shall be performed only when the pod is at the write position.
NOTE 2: The read and write positions may be the same position. The host shall be able to both read and write whenever
PodHold switch is set to Host Release and the pod is at the respective read or write position. Once the host has completed all of
its read and write operations for that pod, then the host sends the PodRelease request to the equipment. The PodRelease service
informs the equipment that pod read or pod write is complete. The PodRelease service has a different purpose from the PodOut
service. The intent of the PodOut service request is to move the pod to a load port, while the intent of the PodRelease service
request is to inform equipment that it may move the pod away from the read or write position. Therefore, PodOut may also be
used with the PodRelease command. If PodHold is Host Release, then the pod shall be kept at the write position until an
PodRelease service request is received, regardless of when a PodOut is sent. If PodHold is set to Equipment Release, then the
PodRelease request has no effect.
20 Additional Events
20.1 This section identifies data collection events that are not related to State transitions for variable data items.
The intent of this section is to ensure certain data is available for specific events that are not related to state
transitions, not to define all the additional collection events for RPMS. Also, all state transitions in RPMS state
models are required to have associated event reports.
20.2 Buffer Capacity Changed Event
20.2.1 An event shall be generated whenever Buffer Capacity changes. This applies to all internal buffers and
internal buffer partitions.

SEMI E109-0305 © SEMI 2001, 2005 57
20.2.2 Data required to be available for this event report:
BufferPartitionInfo
20.3 Pod Closed Event
20.3.1 If the pod is equipped with a door, an event shall be generated when a pod door has been closed.
20.3.2 Data required to be available for this event report:
PodID,
LocationID, and
PortID (if valid).
20.4 Pod Location Change Event
20.4.1 An event shall be generated whenever a pod has changed location. This applies to both load ports, substrate
ports, and internal buffer locations.
20.4.2 Data required to be available for this event report:
PodID,
LocationID (new destination location), and
PodLocationMatrix.
20.5 Pod Opened Event
20.5.1 If the pod is equipped with a door, an event shall be generated when a pod door has been opened.
20.5.2 Data required to be available for this event report:
PodID,
LocationID, and
PortID (if valid).
20.6 PodID Read Fail Event
20.6.1 An event shall be generated when the equipment attempts to read a PodID and fails at a port in the NOT
ASSOCIATED STATE.
20.6.2 Data required to be available for this event report:
PortID
20.7 ID Reader Unavailable Event
20.7.1 An event shall be generated whenever an id reader becomes unavailable for any reason. This applies to all
load ports.
20.7.2 Data required to be available for this event report:
Port ID
20.8 ID Reader Available Event
20.8.1 An event shall be generated whenever an id reader becomes available. This applies to all load ports.
20.8.2
Data required to be available for this event report:
Port ID
20.9 Reticle Usage Warning Limit Event
20.9.1 An Event shall be generated whenever a reticle is nearing the configurable limits of usage

SEMI E109-0305 © SEMI 2001, 2005 58
20.9.2 Data required to be available for this event
ReticleID
20.10 ReticleTransferJob Complete Event
20.10.1 An event shall be generated whenever a ReticleTransferJob completes.
20.10.2 Data required to available for this event:
PodID
21 Variable Data
21.1 The purpose of this section is to define the list of variable data requirements for RPMS equipment. Values of
these variables are available to the host via collection event reports and host status queries. Some of the data items
listed are valid for internal buffer production equipment only, and are marked as such.
21.2 Variable Data Definitions
21.2.1 The following table defines variable data that shall be provided by the production equipment. Also, for the
objects defined by Reticle and Pod Management, the identifier of that object and all of the attributes of that object
shall be available for inclusion in event reports associated with that object. Subscripted variables are used either as
items within a list or to differentiate data representing different entities. Subscripted variables are always valid.
Table 56 Variable Data Definitions
Variable Name Description Type Access Comment
AccessMode
i
The access mode for the i
th
load port.
Enumerated:
MANUAL,
AUTO
RO
AlarmInfo The number of the error
ocurring.
List of 2 items
1. Alarm number
2. Alarm description
RO The supplier is free to add
additional errors beyond what
is defined in the Alarm
Information table, but the
support for alarms defined in
that table are required
#1
.
AvailPartitionCapacity The current available buffer
capacity for a logical
partition inside internal
buffer equipment
(PartitionCapacity # of
pods in partition).
Positive integer RO Only applicable to internal
buffer production equipment.
AvailPartitionCapacity
i
The AvailPartitionCapacity
for the i
th
PartitionID within
the internal buffer.
Positive integer RO Only applicable to internal
buffer production equipment.
BufferCapacityList The current PartitionType,
AvailPartitionCapacity, and
PartitionCapacity for all
logical buffer partitions.
List of n groups of items
1. BufferPartitionInfo
1
.
.
n. BufferPartitionInfo
n
RO Only applicable to internal
buffer production equipment.
BufferPartitionInfo The related information for a
logical buffer partition.
Structure of 4 items
PartitionID
PartitionType
AvailPartitionCapacity
PartitionCapacity
RO Only applicable to internal
buffer production equipment.