semi合集-English.pdf - 第6479页

SEMI G78-0699 © SE MI 1999 12 Suggested Graph s for X-Offset and Y- Offset (see Appen dix 1 for exam ples): X-Offset Y-Offset LOTX + D-D-X LOTY + D-D-Y LOTX LOTY LOTX - D-D-X LOTY - D-D-Y Average Die X- Offset (3) Averag…

100%1 / 7923
SEMI G78-0699 © SEMI 199911
From the last die
of wafer 10 until
the wafer is stored
in the wafer boat
and the boat is
free to be removed
from the prober
(LDT2C)
Start Stopwatch,
prober
From pushing
"start" to the
testing of the first
die on the first
wafe
r
(
S2FDT
or
S2FDT
OCR
)
From beginning to
end of automatic
probe-to-pad
alignment
procedure
Note that this
procedure is to be
performed prior to
wafers 1,2,5 & 8
Using the stopwatch's
"split" function, record
the following times:
APTPA
APTPA
APTPA
A
PTPA
From pushing
"start" to the
testing of the first
die on the second
wafer
(S2FDTW2)
From the last die
of wafer 3 to the
first die of wafer 4
(A2B)
Stop stopwatch at
this time
(TTCC)
1 2 3 4 5 6 7 8 9 10
10.6
10.7
10.9
Figure 9
Timing Procedure
11 Introduction
11.1 The Probe Mark Analysis System recognizes the edge of the bond pad passivation opening and the probe
mark, draws a best-fit rectangle around the probe mark and passivation opening, and returns the four distances, Left,
Right, Bottom and Top to a text file. The center position of the best-fit rectangle can be used to represent the center
of the scrub mark. An offset of this center of scrub mark from the center of the bond pad can be calculated as
follows:
2/)(
2/)(
TopBottomPadYoffset
RightLeftPadXoffset
=
=
(1)
The variation of this offset from pad to pad, die to die, wafer to wafer and setup to setup captures most of the
process variations.
11.2
PMA Data Analysis
11.2.1 We will use a sampling scheme of 9 wafers per lot, (3 setups per lot, 3 wafers per setup), 12 dies per wafer
and 24 pads per die as an example for discussing the data analysis algorithm. The first step of doing data analysis is
to obtain the offsets for all the pads that have been sampled using Eqn.(1). This means that the offsets
yoff
xoff
padmdielwafksetjloti
padmdielwafksetjloti
t][PadYoffse
,
t][PadXoffse
,,,,
,,,,
(2)
for a pad m on die l, wafer k, under setup j in lot i are known.
Step 1
Calculate Average Die Offset for the lot [LOTX or LOTY] (3)
=
=
=
=
12
1
,,,,,,,
12
1
,,,,,,,
12
1
12
1
m
padmdielwafksetjlotidielwafksetjloti
m
padmdielwafksetjlotidielwafksetjloti
yoffyoff
xoffxoff
(3)
Step 2
Calculate D-D-X or D-D-Y = 3σ of Average Die Offset [LOTX] and [LOTY](3)
These die offsets are again treated on the equal basis. A 3σ value is calculated and becomes our Die-to-Die
Variation (D-D-X, D-D-Y) for the entire lot.
LOTX + D-D-X, LOTX - D-D-X = Total Prober X-Error Range (3σ)
LOTY + D-D-Y, LOTY - D-D-Y = Total Prober Y-Error Range (3σ)
SEMI G78-0699 © SEMI 1999 12
Suggested Graphs for X-Offset and Y-Offset (see Appendix 1 for examples):
X-Offset Y-Offset
LOTX + D-D-X LOTY + D-D-Y
LOTX LOTY
LOTX - D-D-X LOTY - D-D-Y
Average Die X-Offset (3) Average Die Y-Offset (3)
12 Data Collection Table
12.1 The following data are to be recorded about the test environment:
Title Description Values
Installed (Yes/No)
kg
Tester - Prober Interface
If installed, Total Pogo
®
pin force (nominal, calculated)
pounds
Present [docked] (Yes/No)Tester
If present, state manufacturer and
model
Wafer Nominal Die Size (Small, Medium
or Large)
Needle count
gramsNominal force per needle
ounces
micronsDiameter of needle tip
mils
micronsNeedle pitch (within a single row or
column)
mils
Number of needle tiers
mm
Size of needle array in the X
direction (left-to-right when facing
prober (from the operator position))
inches
mmSize of needle array in the Y
direction (away and towards the
operator relative to the center of the
probe card)
inches
mm
Probe Card
Diameter of probe card
inches
ºCSet point / Temperature of chuck
during test
ºF
Soak time, probe card (if test
temperature is other than ambient)
minutes
Test Temperature
Soak time, prober (if other than
ambient)
minutes
SEMI G78-0699 © SEMI 199913
Title Description Values
microns
X-direction
mils
microns
DUT spacing
Y-direction
mils
micronsZ clearance
mils
micronsOverdrive
mils
Tester-Prober communications method
OCR on? (Y/N)
SEMI standard font? (Y/N)
OCR Variables
# of retries allowed
Definitions for formulae:
Variable Description Values
DPW
Die Per Wafer
TT
Test Time (minimum value of 1.0 seconds) seconds
Data Collected Description Values
A2B Last die (Wafer A) to first die (Wafer B) time seconds
S2FDT Time from pushing "Start" to First Die Test with OCR
turned off
seconds
S2FDT
OCR
Time from pushing "Start" to First Die Test with OCR
turned on
seconds
S2FDTW2 Time from pushing “Start” to First Die Test, Wafer #2 seconds
LDT2C
Time from end of Last Die Test to Cassette free to remove
from prober
seconds
TTCT Total Time to Complete Test seconds
TTAA Time To Auto-Align the probe needles with the die bonding
pads
seconds
9
D
P
W
3) (TTAALDT2C S2FDTW28)(A2B9)DPW(TTTTCT
D2D
×
××××
=
Calculated Results Values
D2D seconds