SEMI S13-0305 © SEMI 1998, 2005 10 RELATED INFORMATION 2 DOCUMENT CRITERIA INCLUDED IN SEMI S2 NOTICE : This rel ated inform ation is not an official part of SEMI S 13 and was derived from SEMI S2. T h is related informa…

100%1 / 7923
SEMI S13-0305 © SEMI 1998, 2005 9
RELATED INFORMATION 1
LAWS AND REGULATIONS
NOTICE: This related information is not an official part of SEMI S13 and was derived from the work of the SEMI
S13 Revision Task Force. This related information was approved for publication by a letter ballot on November 24,
2004.
R1-1 Laws and Regulations
R1-1.1 The contents of this section should be addressed in the terms and conditions of sale or other contractual
agreements between the supplier and user. The following information may be included in the documents provided
to the equipment user.
R1-1.2 Relevant Administrative Laws and Regulations — These may include laws and regulations relevant to
installation, operation, maintenance, and decommissioning of the equipment.
R1-1.2.1 The supplier may describe, in the documents provided to the equipment user, the laws and regulations
related to EHS of the user’s jurisdiction relevant to operation, maintenance, and supervision of the system.
R1-1.2.2 The supplier may describe the measure of support by the supplier for the implementation of laws and
regulations related to EHS after delivery of the equipment.
NOTE 1: It is recommended that equipment supplier and equipment user jointly investigate the laws and regulations of the
jurisdiction where the equipment is to be used, and they incorporate these requirements into the purchase specification. In
addition, the supplier has a right to describe the laws and regulations considered, and means of compliance implemented, during
the development and production of the equipment.
R1-1.3 Issues Regarding Product Liability (PL)
R1-1.3.1 The supplier may describe the following in the documents provided to the equipment user to ensure
mutual understanding of the issues regarding product liability for the equipment:
R1-1.3.1.1 How a field retrofit is announced and implemented.
R1-1.3.1.2 How to notify discontinuance information of the equipment production to the equipment user and what
repair and maintenance services are available after discontinuation of production of the equipment.
R1-1.3.1.3 How parts should be handled by the user for the transport for repair.
R1-1.3.1.4 The equipment supplier should describe, in the documents provided to the equipment user, the
possibility of not being able to carry out servicing for reasons of safety and health of the dispatched personnel, if the
equipment user refuses to disclose the names and contents of materials being used, for reasons of confidentiality or
trade secret protection.
R1-1.3.1.5 The limit of the responsibility of the equipment supplier when the equipment user transports, reuses,
resells, or modifies the equipment without the equipment supplier’s agreement.
R1-1.3.1.6 The responsibility with regard to the parts designed by the equipment user without the approval of the
equipment supplier.
SEMI S13-0305 © SEMI 1998, 2005 10
RELATED INFORMATION 2
DOCUMENT CRITERIA INCLUDED IN SEMI S2
NOTICE: This related information is not an official part of SEMI S13 and was derived from SEMI S2. This
related information was approved for publication by a letter ballot on November 24, 2004.
R2-1 Purpose of this Related Information
R2-1.1 This related information contains criteria for documents that are presented in SEMI S2.
R2-1.2 The criteria in this related information are included in SEMI S2 as of the time this related information was
written, and are included herein for the convenience of users of this document.
NOTE 1: The information in this related information may not be current with the source document. The source document
contains the actual documentation criteria.
R2-1.3 The criteria in this related information are arranged to correspond with the sections of SEMI S2.
NOTE 2: It was the intent of the Task Force responsible for SEMI S13 that this related information be updated to incorporate
future revisions of SEMI S2 related to criteria for documents.
R2-2 Safety Interlock Systems
R2-2.1 SEMI S2-0703, ¶11.7.2.2 — If a safety interlock is defeated, the maintenance manual should identify
administrative controls to safeguard personnel or to minimize the hazard.
R2-3 Emergency Shutdown
R2-3.1 In case assemblies that are not intended to be used as stand-alone equipment and EMO circuit is not
necessary in the assemblies of the equipment, assembly’s installation manual should provide clear instructions to the
equipment installer to connect the assembly to the integrated system’s emergency off circuit, (based on SEMI S2-
0703, ¶12.1).
R2-3.1.1 SEMI S2-0703, ¶12.1.1 — If the supplier provides an external EMO interface on the equipment, the
supplier should include instructions for connecting to the interface.
R2-4 Electrical Design
R2-4.1 SEMI S2-0703, ¶13.3 — Routine Type 4 tasks, excluding troubleshooting, should have specific written
instructions in the maintenance manuals.
R2-4.2 SEMI S2-0703, ¶13.4.9 — The current interrupting capacity (also known as amperes interrupting capacity,
or AIC) of the equipment main disconnect should be identified in the facility installation and maintenance manuals.
R2-4.3 SEMI S2-0703, ¶13.5.1 — Whenever a UPS is provided with the equipment, its location and wiring should
be clearly described within the installation and maintenance manual.
R2-5 Seismic Information
R2-5.1 SEMI S2-0703, ¶19.3 — The supplier should provide the following data and procedures to the user. This
information should be included in the installation instructions as part of the documentation covered in §9.
A drawing of the equipment, its support equipment, its connections (e.g., ventilation, water, vacuum, gases) and
the anchorage locations identified in ¶19.4.
The type of feet used and their location on a base frame plan drawing.
The weight distribution on each foot.
Physical dimensions, including width, length, and height of each structurally independent module.
Weight and location of the center of mass for each structurally independent module.
Acceptable locations on the equipment frame for anchorage.
SEMI S13-0305 © SEMI 1998, 2005 11
R2-6 Environmental Information
R2-6.1 SEMI S2-0703, ¶9.4 — The manufacturer should provide the user with the following environmental
documentation as applicable:
R2-6.1.1 ¶9.4.1 — Energy consumption information, including idle, average, and peak operating conditions, for the
manufacturer’s most representative (“baseline”) process.
R2-6.1.2 ¶9.4.2 — Mass balance, including idle, average, and peak operating conditions, for the manufacturer’s
most representative (“baseline”) process.
NOTE 3: The mass balance may include resource consumption rates, chemical process efficiencies, wastewater effluent and air
emission characterization, solid and hazardous waste generation (quantity and quality), and by-products.
R2-6.1.3 ¶9.4.3 — Information regarding routes of unintended release (of effluents, wastes, emissions, and by-
products) and methods and devices to monitor and control such releases. This should include information on
features to monitor, prevent, and control unintended releases (see ¶21.2.4).
R2-6.1.4 ¶9.4.4 — Information regarding routes of intended release (of effluents, wastes, and emissions) and
features to monitor and control such releases (see ¶21.2.5).
R2-6.1.5 ¶9.4.5 — A list of items that become solid waste as a result of the operation, maintenance, and servicing
of the equipment, and that are constructed of or contain substances whose disposal might be regulated (e.g.,
beryllium-containing parts, vapor lamps, mercury switches, batteries, contaminated parts, maintenance wastes).
R2-7 Exhaust Ventilation
R2-7.1 SEMI S2-0703, ¶22.3 — Documentation should be developed showing the equipment exhaust parameters
and relevant test methods, and should include (see also Appendix 2):
duct velocity (where needed to transport solid particles);
volumetric flow rate Q;
capture velocity (where airborne contaminants are generated outside an enclosure);
face velocity (where applicable);
hood entry loss factor F
h
or K;
coefficient of entry C
e.
;
hood static pressure SP
h
;
duct diameter at the point of connection to facilities; and
location(s) on the duct or hood where all ventilation measurements were taken.
R2-8 Manuals
R2-8.1 SEMI S2-0703, ¶9.6
R2-8.1.1 ¶9.6.1 — The supplier should provide the user with manuals based on the originally intended use of the
equipment. The manuals should describe the scope and normal use of the equipment, and provide information to
enable safe facilitization, operation, maintenance, and service of the equipment.
R2-8.1.2 ¶9.6.2 — The manuals should conform to SEMI S13.
NOTE 4: Fire suppression agents, and chemicals used to test fire detection or suppression systems, fall under the MSDS
provisions of SEMI S13 when they are provided with the equipment.
NOTE 5: Hazardous energies within fire detection or suppression systems fall under the hazardous energy control provisions of
SEMI S13 when fire detection or suppression systems are provided with the equipment.
R2-8.1.3 ¶9.6.3 — In addition to the provisions of SEMI S13, the manuals should include:
specific written instructions on routine Type 4 tasks, excluding troubleshooting (refer to ¶13.3);