SEMI E54.4-0704 © SEMI 1997, 2004 14 DeviceNet Statement of Comp liance Connection Object 0x05 Object Class ID Description Get Set Value Limits Attributes Open 1 Revision ❑ ❑ ___________________ ❑ None Supported DeviceNe…

SEMI E54.4-0704 © SEMI 1997, 2004 13
DeviceNet Statement of Compliance
DeviceNet Object 0x03
Object Class ID Description Get Set Value Limits
Attributes Open 1 Revision ❑ ❑ ___________________
❑ None Supported
DeviceNet Services Parameter Options
Services ❑ Get_Attribute_Single ____________________________
❑ None Supported
Object Instance ID Description Get Set Value Limits
Attributes Open 1 MAC ID ❑ ❑ ___________________
2 Baud rate ❑ ❑ ___________________
❑ None Supported 3 BOI ❑ ❑ ___________________
4 Bus-off counter ❑ ❑ ___________________
5 Allocation information ❑ ❑ ___________________
6 MAC ID switch changed ❑ ❑ ___________________
7 Baud rate switch changed ❑ ❑ ___________________
8 MAC ID switch value ❑ ❑ ___________________
9 Baud rate switch value ❑ ❑ ___________________
DeviceNet Services Parameter Options
Services ❑ Get_Attribute_Single ____________________________
❑ Set_Attribute_Single ____________________________
❑ None Supported ❑ Allocate M/S connection set ____________________________
❑ Release M/S connection set ____________________________
Vendor-Specific Additions If yes, fill out Vendor-Specific Yes ❑
DeviceNet
Required
Object
Implementation
Additions form on page F_7. No ❑
X Get to indicate that attribute value is returned by the use of Get_Attribute_Single service.
X Set to indicate that attribute value is written to by the use of Set_Attribute_Single service.
F_ 4

SEMI E54.4-0704 © SEMI 1997, 2004 14
DeviceNet Statement of Compliance
Connection Object 0x05
Object Class ID Description Get Set Value Limits
Attributes Open 1 Revision ❑ ❑ ___________________
❑ None Supported
DeviceNet
Required
Object
Implementation
DeviceNet Services Parameter Options
Services ❑ Reset
_
__________________________
_
❑ Create
_
__________________________
_
❑None Supported ❑ Delete
_
__________________________
_
❑ Get_Attribute_Single
_
__________________________
_
❑ Find_Next_Object_Instance _
_
_________________________
_
Total Active Connections _______________________________
Possible __________
Object Instance Section Information Max
Instance type Explicit Message ❑ _______
Polled I/O ❑ _______
Bit Strobed I/O ❑ _______
Dynamic I/O ❑ _______
Production trigger Cyclic ❑ _______
The Object Instance section must
be completed for each
combination of Instance type,
Production trigger, Transport
type, and Transport class
supported
Change of State ❑ _______
Application Trig. ❑ _______
Transport type Server ❑ _______
Client ❑ _______
Transport class 0 ❑ _______
2 ❑ _______
3 ❑ _______
ID Description Get Set Value Limits
Attributes Open 1 State
2 Instance type
❑ ❑ _______
❑ ❑ _______
3 Transport class trigger ❑ ❑ _______
4 Produced connection ID ❑ ❑ _______
5 Consumed connection ID ❑ ❑ _______
6 Initial comm. characteristics ❑ ❑ _______
7 Produced connection size ❑ ❑ _______
8 Consumed connection size ❑ ❑ _______
9 Expected packet rate ❑ ❑ _______
12 Watchdog time-out action ❑ ❑ _______
13 Produced connection path length
❑ ❑ _______
14 Produced connection path ❑ ❑ _______
15 Consumed connection path length ❑ ❑ _______
16 Consumed connection path ❑ ❑ _______
DeviceNet Services Parameter Options
Services
❑ Reset
_
__________________________
_
❑ Delete
_
__________________________
_
❑ Apply_Attributes
_
__________________________
_
❑ Get_Attribute_Single
_
__________________________
_
❑ Set_Attribute_Single
_
__________________________
_
Vendor-Specific Additions
If yes, fill out the Vendor-Specific Yes ❑
Additions form on page F_7. No ❑
X Get to indicate that attribute value is returned by the use of Get_Attribute_Single service.
X Set to indicate that attribute value is written to by the use of Set_Attribute_Single service.
F_ 5

SEMI E54.4-0704 © SEMI 1997, 2004 15
OBJECT NAME Device Manager
OBJECT ID 64
Object Class ID Description Get Set Value Limits
Attributes Open _____ ________________ ❑ ❑ ___________________
DeviceNet Services Parameter Options
Services ____________________________ ____________________________
DeviceNet
Open
Object
Implementation
Object Instance ID Description Get Set Value Limits
Attributes Open 31 Device Type ❑ ❑ ___________________
32 Standard Revision Level ❑ ❑ ___________________
33 Device Manufacturer ID ❑ ❑ ___________________
34 Manufacturer Model Number ❑ ❑ ___________________
35 Soft/Firmware Rev. Level ❑ ❑ ___________________
36 Hardware Revision Level ❑ ❑ ___________________
37 Serial Number ❑ ❑ ___________________
38 Device Configuration ❑ ❑ ___________________
39 Device Status ❑ ❑ ___________________
3A Reporting Mode ❑ ❑ ___________________
3B Exception Status Timer ❑ ❑ ___________________
3C Exception Status ❑ ❑ ___________________
3D Exception Detail Alarm ❑ ❑ ___________________
3E Exception Detail Warning ❑ ❑ ___________________
DeviceNet Services Parameter Options
Services ❑ Reset ____________________________
❑ Abort ____________________________
❑ Recover ____________________________
❑ Get_Attribute_Single ____________________________
❑ Set_Attribute_Single ____________________________
❑ Execute ____________________________
❑ Perform Diagnostics ____________________________
Meaning of Zero Length I/O Data Production______________________________________________
Vendor-Specific Additions
If yes, fill out the Vendor-Specific Yes ❑
Additions form on page F_7. No ❑
X Get to indicate that attribute value is returned by the use of Get_Attribute_Single service.
X Set to indicate that attribute value is written by the use of Set_Attribute_Single service.