semi合集-English.pdf - 第6481页
SEMI G78-0699 © SE MI 1999 14 A P PENDIX 1 CALCULATION OF NOR M AL IZED DIE OFFSET AND TOTA L PROBER ERROR RANGE (3 σ σ σ σ ) A 1-1 Probe M ark Data Analysis Al g orithm: A1-1 .1 Introducti on A1- 1.1.1 The P robe Mark A…

SEMI G78-0699 © SEMI 199913
Title Description Values
microns
X-direction
mils
microns
DUT spacing
Y-direction
mils
micronsZ clearance
mils
micronsOverdrive
mils
Tester-Prober communications method
OCR on? (Y/N)
SEMI standard font? (Y/N)
OCR Variables
# of retries allowed
Definitions for formulae:
Variable Description Values
DPW
Die Per Wafer
TT
Test Time (minimum value of 1.0 seconds) seconds
Data Collected Description Values
A2B Last die (Wafer A) to first die (Wafer B) time seconds
S2FDT Time from pushing "Start" to First Die Test with OCR
turned off
seconds
S2FDT
OCR
Time from pushing "Start" to First Die Test with OCR
turned on
seconds
S2FDTW2 Time from pushing “Start” to First Die Test, Wafer #2 seconds
LDT2C
Time from end of Last Die Test to Cassette free to remove
from prober
seconds
TTCT Total Time to Complete Test seconds
TTAA Time To Auto-Align the probe needles with the die bonding
pads
seconds
9
D
P
W
3) (TTAALDT2C S2FDTW28)(A2B9)DPW(TTTTCT
D2D
×
×−−−×−××−
=
Calculated Results Values
D2D seconds

SEMI G78-0699 © SEMI 1999 14
APPENDIX 1
CALCULATION OF NORMALIZED DIE OFFSET AND TOTAL PROBER
ERROR RANGE (3σ
σσ
σ)
A1-1 Probe Mark Data Analysis Algorithm:
A1-1.1 Introduction
A1-1.1.1 The Probe Mark Analysis syst em recognizes the edge of the bond pad passivation opening and the probe
mark, draws a best-fit rectangle around the probe mark and passivation opening, and returns the four distances, Left,
Right, Bottom and Top to a text file. The center position of the best-fit rectangle can be used to represent the center
of the scrub mark. An offset of this center of scrub mark from the center of the bond pad can be calculated as
follows:
2/)(
2/)(
TopBottomPadYoffset
RightLeftPadXoffset
−=
−=
(1)
A1-1.1.2 The variation of this offset fro m pad to pad, die to die, wafer to wafer and setup to setup captures most of
the process variations.
A1-1.2
PMA Data Analysis
A1-1.2.1 We will use a sampling scheme of 9 wafers per lot, (3 setups per lot, 3 wafers per setup), 12 die per wafer
and 24 pads per die. The first step of doing data analysis is to obtain the offsets for all the pads that have been
sampled using Eqn.(1). This means that the offsets
yoff
x
off
padmdielwafksetjloti
padmdielwafksetjloti
t][PadYoffse
,
t][PadXoffse
,,,,
,,,,
(2)
for a pad m on die l, wafer k, under setup j in lot i are known.
A1-1.3 Step 1 — Calculate
Average Die Offset (3)
loti setj wafk diel loti setj wafk diel padm
m
loti setj wafk diel loti setj wafk diel padm
m
xoff xoff
yoff yoff
,, , ,, ,,
,, , ,, , ,
=
=
=
=
1
12
1
12
1
12
1
12
(3)
A1-1.3.1 Discussion of Average Die Off set
A1-1.3.1.1 Based on the sample described , there will be an Average Die Offset-X and Average Die Offset Y for
each of the 108 die sampled. This value is probably the most descriptive, especially when graphed (see example
graphs). Both X and Y-graphs will most likely resemble a sine wave. This is due to wafer rotation. As you
serpentine across the wafer there will be a slight offset from die to die. Since the selected sample dice are in the
center and around the edges of the wafer, you can see the progression of the offset as you move farther from the
center of the wafer. The X and Y graphs are usually about 90º out of phase.
A1-1.3.1.2
Other qualitative information can also be gathered by visually looking at the graphs of this data. One
can determine whether the accuracy is varying wafer to wafer (each set of 12 data points is a wafer) or set-up to set-
up (each set of 36 data points is a set-up) or just drifting over time. Drift over time is sometimes caused by
temperature stabilization issues within the prober mechanism. Subsequent steps will quantify how much variability
is caused by each.

SEMI G78-0699 © SEMI 199915
A1-1.4 Step 2 — Calculate
Normalized (by die) Pad Offset (4) = (2) - Average Die Offset (3)
loti setj wafk diel padm
loti setj wafk diel padm loti setj wafk diel
loti setj wafk diel padm loti setj wafk diel padm loti setj wafk diel
xnorm
x
off
x
off
ynorm yoff yoff
,, ,,
,, , , ,, ,
,, , , ,, ,, ,, ,
=−
=−
(4)
A1-1.4.1 Discussion of Normalized (by die) Pad Offset
A1-1.4.1.1 This step helps to quantify how much error is caused by the prober vs. the probe card. The probe card
usually does NOT impact average offset of a die, just the variability within a die. In this equation, we subtract the
average die offset (presumed prober error) from each pad in that die. This data is then used for the next step.
A1-1.5 Step 3 — Calculate
P-P-X or P -P-Y = 3σ of Normalized (by die) Pad Offset (4).
A1-1.5.1 All the normalized pad offsets in the same lot (no matter on which die, on which wafer the pad resides)
are treated on an equal basis. In our example, a total of 2592 pads are sampled in a lot. All 1296 x-direction and
1296 y-direction pads of Normalized (by die) Pad Offset will be used to calculate a 3σ variation which is called
Pad-to-Pad variation
(P-P-X and P-P-Y).
A1-1.5.2 Discussion of P-P-X or P-P-Y (Pad-to-Pad Variation in the X-direction or Pad-to-Pad-Variation in the Y-
direction)
A1-1.5.2.1 These values describe how mu ch variability there is within all the pads in the lot. This value is
frequently attributed to probe tip variation in X, Y, and Z. Although probe tips do change and wear over time, their
unloaded position usually does not change dramatically within one lot. This value does not help tremendously in
describing prober accuracy nor should it be used for any sort of probecard metrology. However, be sure to perform
a mental reality check to verify that it is somewhere near (within an order of magnitude of) your probe card X/Y
probe needle position specification.
A1-1.6
Step 4 — Calculate
Average W afer Offset (5) = average of Average Die Offset (3).
loti setj wafk loti setj wafk diel
l
loti setj wafk loti setj wafk diel
l
xoff xoff
yoff yoff
,, ,, ,
,, ,, ,
=
=
=
=
1
12
1
12
1
12
1
12
(5)
A1-1.6.1 Discussion of Average Wafer O ffset
A1-1.6.1.1 This equation will result in nine values for Average Wafer Offset-X and nine for Average Wafer Offset-
Y. These numbers could also be graphed to look for trends from wafer to wafer (this is not included on the example
graphs). If there is a consistent trend in one direction possible causes are:
• wafer loading error
• cumulative stepping error, and
• temperature stability errors