SEMI S2-0703a E © SEMI 1991, 2004 6 NOTE 6: For the purpose of this guideline, a “series of events” is limited to those events resulting from a single point failure. See also Section 6.5. 5.2.45 noncomb ustible material …

100%1 / 7923
SEMI S2-0703a
E
© SEMI 1991, 2004 5
5.2.27 hazardous voltage — unless otherwise defined
by an appropriate international standard applicable to
the equipment, voltages greater than 30 volts rms, 42.4
volts peak, 60 volts dc are defined in this document as
hazardous voltage.
NOTE 4: The specified levels are based on normal conditions
in a dry location.
5.2.28 hood — in the context of Section 22 and
Appendix 2 of this guideline, “hood” means a shaped
inlet designed to capture contaminated air and conduct
it into an exhaust duct system.
5.2.29 hood entry loss factor (K or F
h
) — a unitless
factor that quantifies hood efficiency. If the hood is
100% efficient, then K or F
h
= 0. Related equations:
Q = 4.043A[(SP
h
/d)/(1+F
h
)]
0.5
where:
Q = volumetric flow rate in m
3
/sec,
A = cross sectional area of the duct in m
2
,
SP
h
= hood static pressure in mm water gauge (w.g.),
and d = density correction factor (unitless).
(US units: Q = 4005A[(SP
h
/d)/(1+F
h
)]
0.5
where:
Q = volumetric flow rate in cfm.
A = cross sectional area of the duct in ft
2
,
SP
h
= hood static pressure in inches water gauge (w.g.),
and d = density correction factor (unitless).)
5.2.30 incompatible — as applied to chemicals: in the
context of Section 23 of this guideline, describes
chemicals that, when combined unintentionally, may
react violently or in an uncontrolled manner, releasing
energy that may create a hazardous condition.
5.2.31 intended reaction product — chemicals that are
produced intentionally as a functional part of the
semiconductor manufacturing process.
5.2.32 interlock — a mechanical, electrical or other
type of device or system, the purpose of which is to
prevent or interrupt the operation of specified machine
elements under specified conditions.
5.2.33 ionizing radiation — alpha particles, beta
particles, gamma rays, x-rays, neutrons, high-speed
electrons, high-speed protons, and other particles
capable of producing ions in human tissue.
5.2.34 laser — any device that can be made to produce
or amplify electromagnetic radiation in the wavelength
range from 180 nm to 1 mm primarily by the process of
controlled stimulated emission.
5.2.35 laser product — any product or assembly of
components that constitutes, incorporates, or is intended
to incorporate a laser or laser system (including laser
diode), and that is not sold to another manufacturer for
use as a component (or replacement for such
component) of an electronic product.
5.2.36 laser source — any device intended for use in
conjunction with a laser to supply energy for the
excitation of electrons, ions, or molecules. General
energy sources, such as electrical supply mains, should
not be considered to be laser energy sources.
5.2.37 laser system — a laser in combination with an
appropriate laser energy source, with or without
additional incorporated components.
5.2.38 likelihood — the expected frequency with
which a mishap will occur. Usually expressed as a rate
(e.g., events per year, per product, or per substrate
processed).
5.2.39 local exhaust ventilation — local exhaust
ventilation systems operate on the principle of
capturing a contaminant at or near its source and
moving the contaminant to the external environment,
usually through an air cleaning or a destructive device.
It is not to be confused with laminar flow ventilation.
Synonyms: LEV, local exhaust, main exhaust,
extraction system, module exhaust, individual exhaust.
5.2.40 lower explosive limit — the minimum
concentration of vapor in air at which propagation of
flame will occur in the presence of an ignition source.
Synonyms: LEL, lower flammability limit (LFL).
5.2.41 maintenance — planned or unplanned activities
intended to keep equipment in good working order.
(See also the definition for service.)
5.2.42 mass balance — a qualitative, and where
possible, quantitative, specification of mass flow of
input and output streams (including chemicals, gases,
water, deionized water, compressed air, nitrogen, and
by-products), in sufficient detail to determine the
effluent characteristics and potential treatment options.
5.2.43 material safety data sheet (MSDS) — written or
printed material concerning chemical elements and
compounds, including hazardous materials, prepared in
accordance with applicable standards.
NOTE 5: Examples of such standards are USA government
regulation 29 CFR 1910.1200, and Canadian WHMIS
(Workplace Hazardous Material Information System).
5.2.44 mishap — an unplanned event or series of
events that results in death, injury, occupational illness,
damage to or loss of equipment or property, or
environmental damage.
SEMI S2-0703a
E
© SEMI 1991, 2004 6
NOTE 6: For the purpose of this guideline, a “series of
events” is limited to those events resulting from a single point
failure. See also Section 6.5.
5.2.45 noncombustible material — a material that, in
the form in which it is used and under the conditions
anticipated, will not ignite, burn, support combustion,
or release flammable vapors when subjected to fire or
heat. Typical noncombustible materials are metals,
ceramics, and silica materials (e.g., glass and quartz).
(See also the definition for combustible material.)
5.2.46 non-ionizing radiation — forms of electro-
magnetic energy that do not possess sufficient energy to
ionize human tissue by means of the interaction of a
single photon of any given frequency with human
tissue. Non-ionizing radiation is customarily identified
by frequencies from zero hertz to 3 × 10
15
hertz
(wavelengths ranging from infinite to 100 nm). This
includes: static fields (frequencies of 0 hertz and
infinite wavelengths); extremely low frequency fields
(ELF), which includes power frequencies; subradio-
frequencies; radiofrequency/microwave energy; and
infrared, visible, and ultraviolet energies.
5.2.47 non-recycling, deadman-type abort switch — a
type of abort switch that must be constantly held closed
for the abort of the fire detection or suppression system.
In addition, it does not restart or interrupt any time
delay sequence for the detection or suppression system
when it is activated.
5.2.48 occupational exposure limits (OELs) — for the
purpose of this document, OELs are generally
established on the basis of an eight hour workday.
Various terms are used to refer to OELs, such as
permissible exposure levels, Threshold Limit Values
,
maximum acceptable concentrations, maximum
exposure limits, and occupational exposure standards.
However, the criteria used in determining OELs can
differ among the various countries that have established
values. Refer to the national bodies responsible for the
establishment of OELs. (Threshold Limit Value is a
registered trademark of the American Conference of
Governmental Industrial Hygienists.)
5.2.49 operator — a person who interacts with the
equipment only to the degree necessary for the
equipment to perform its intended function.
5.2.50 parts-cleaning hood — exhausted hood used for
the purpose of cleaning parts or equipment. Synonym:
equipment cleaning hood.
5.2.51 positive-opening — as applied to
electromechanical control devices. The achievement of
contact separation as a direct result of a specified
movement of the switch actuator through non-resilient
members (i.e.
, contact separation is not dependent upon
springs).
5.2.52 potentially hazardous non-ionizing radiation
emissions — for the purposes of this guideline, non-
ionizing radiation emissions outside the limits shown in
Appendix 5 are considered potentially hazardous.
5.2.53 pyrophoric material — a chemical that will
spontaneously ignite in air at or below a temperature of
54.4C (130F).
5.2.54 radio frequency (rf) — electromagnetic energy
with frequencies ranging from 3 kHz to 300 GHz.
Microwaves are a portion of rf extending from 300
MHz to 300 GHz.
5.2.55 readily accessible capable of being reached
quickly for operation or inspection, without requiring
climbing over or removing obstacles, or using portable
ladders, chairs, etc.
5.2.56 recognized — as applied to standards; agreed to,
accepted, and practiced by a substantial international
consensus.
5.2.57 rem — unit of dose equivalent. Most
instruments used to measure ionizing radiation read in
dose equivalent (rems or sieverts). 1 rem = 0.01 sievert.
5.2.58 reproductive toxicants — chemicals that are
confirmed or suspected to cause statistically significant
increased risk for teratogenicity, developmental effects,
or adverse effects on embryo viability or on male or
female reproductive function at doses that are not
considered otherwise maternally or paternally toxic.
5.2.59 residual — as applied to risks or hazards: that
which remains after engineering, administrative, and
work practice controls have been implemented.
5.2.60 risk — the expected losses from a mishap,
expressed in terms of severity and likelihood.
5.2.61 safe shutdown condition — a condition in which
all hazardous energy sources are removed or suitably
contained and hazardous production materials are
removed or contained, unless this results in additional
hazardous conditions.
5.2.62 safety critical part — discrete device or
component, such as used in a power or safety circuit,
whose proper operation is necessary to the safe
performance of the system or circuit.
5.2.63 service — unplanned activities intended to
return equipment that has failed to good working order.
(See also the definition for maintenance.)
5.2.64 severity — the extent of the worst credible loss
from a mishap caused by a specific hazard.
SEMI S2-0703a
E
© SEMI 1991, 2004 7
5.2.65 sievert (Sv) — unit of dose equivalent. Most
instruments used to measure ionizing radiation read in
dose equivalent (rems or sieverts). 1 Sv = 100 rems.
5.2.66 standard temperature and pressure — for
ventilation measurements, either dry air at 21C (70F)
and 760 mm (29.92 inches) Hg, or air at 50% relative
humidity, 20C (68F), and 760 mm (29.92 inches) Hg.
5.2.67 supervisory alarm — as applied to fire detection
or suppression systems; an alarm indicating a
supervisory condition.
5.2.68 supervisory condition — as applied to fire
detection or suppression systems; condition in which
action or maintenance is needed to restore or continue
proper function.
5.2.69 supplemental exhaust — local exhaust
ventilation that is used intermittently for a specific task
of finite duration.
5.2.70 supplier — party that provides equipment to,
and directly communicates with, the user. A supplier
may be a manufacturer, an equipment distributor, or an
equipment representative. (See also the definition for
user.)
5.2.71 testing — the term “testing” is used to describe
measurements or observations used to validate and
document conformance to designated criteria.
5.2.72 trouble alarm — as applied to fire detection or
suppression systems; an alarm indicating a trouble
condition.
5.2.73 trouble condition — as applied to fire detection
or suppression systems; a condition in which there is a
fault in a system, subsystem, or component that may
interfere with proper function.
5.2.74 user — party that acquires equipment for the
purpose of using it to manufacture semiconductors.
(See also the definition for supplier.)
5.2.75 velocity pressure (VP) — the pressure required
to accelerate air from zero velocity to some velocity V.
Velocity pressure is proportional to the kinetic energy
of the air stream. Associated equation:
VP = (V/4.043)
2
, where V = air velocity in m/s, and VP
= velocity pressure in mm water gauge (w.g.).
[U.S. units: VP = (V/4005)
2
, where
V = velocity in feet per second, and
VP = velocity pressure in inches water gauge (w.g.)]
5.2.76 volumetric flow rate (Q) — in the context of
Section 22 and Appendix 2 of this guideline, Q = the
volume of air exhausted per unit time. Associated
equation: Q = VA, where V = air flow velocity, and A
= the cross-sectional area of the duct or opening
through which the air is flowing at standard conditions.
5.2.77 wet station — open surface tanks, enclosed in a
housing, containing chemical materials used in the
manufacturing of semiconductor materials. Synonyms:
wet sink, wet bench, wet deck.
6 Safety Philosophy
6.1 A primary objective of the industry is to eliminate
or control hazards during the equipment’s life cycle
(i.e., the installation, operation, maintenance, service,
and disposal of equipment).
6.2 The assumption is made that operators,
maintenance personnel, and service personnel are
trained in the tasks that they are intended to perform.
6.3 The following should be considered in the design
and construction of equipment:
regulatory requirements;
industry standards;
this guideline; and
good engineering and manufacturing practices.
6.4 This guideline should be applied during the design,
construction, and evaluation of semiconductor
equipment, in order to reduce the expense and
disruptive effects of redesign and retrofit.
NOTICE: Section 6.5 below will be withdrawn
upon July 1, 2006 publication and replaced by the
new Section 6.5 including: figures and tables as
shown in Delayed Revisions Section 2. The EH&S
Committee has voted that implementation of the
information is OPTIONAL before the effective date.
6.5 No reasonably foreseeable single-point failure
condition or operational error should allow exposure of
personnel, facilities, or the community to hazards that
could result in death, significant injury, or significant
equipment damage.
NOTE 7: The intent is to control single fault conditions that
result in significant risks (i.e., Critical, High, or Medium risks
based on the example risk assessment matrix in SEMI S10).
6.6 Equipment safety features should be fail-safe or of
a fault-tolerant design and construction.
6.7 Components and assemblies should be used in
accordance with their manufacturers’ ratings and
specifications, where using them outside the ratings
would create a safety hazard.
6.8 A hazard analysis should be performed to identify
and evaluate hazards. The hazard analysis should be