semi合集-English.pdf - 第269页

SEMI E43-0301 © SEMI 1995 , 2001 17 that can be performed w it h the equ ipment operat ing on- line, wi t hout altering or disturbi ng its operation. R4-4 ESD and EMI R4-4.1 W hen ESD occurs, the discharge time is usual …

100%1 / 7923
SEMI E43-0301 © SEMI 1995, 2001 16
RELATED INFORMATION 4
OTHER METHODS FOR DETECTING STATIC CHARGE AND ESD
EVENTS IN EQUIPMENT
NOTE: This related information is not an official part of this standard. However, it contains relevant information for using the
standard in situations commonly encountered with semiconductor manufacturing facilities and equipment. Determination of the
suitability of the material is solely the responsibility of the user.
R4-1 Introduction
R4-1.1 Static charge generation is unavoidable
whenever materials come in contact. Without a static
control program, the problems caused by static charge
are also unavoidable. The most common problem
caused by static charge is electrostatic discharge (ESD).
ESD results in damaged semiconductor ICs, photomask
defects, magneto-resistive (MR) read head defects in
disk drives, and failures of the drive circuits for flat
panel displays (FPD). ESD also creates a significant
amount of electromagnetic interference (EMI). Often
mistaken for software errors, EMI resulting from ESD
interrupts the operation of production equipment. This
is particularly true of equipment depending on high-
speed microprocessors for control. Results include
unscheduled downtime, increased maintenance
requirements, and frequently, product scrap.
Technology trends to smaller device geometries, faster
operating speeds, and increased circuit density make
ESD problems worse.
6
R4-1.2 For many years static control programs
concentrated on protecting components from the charge
generated on the personnel that handled them. Many
static control methods were devised to control the
charge on people including wrist and heel straps,
dissipative shoes and flooring, and garments.
Increasingly, however, the production of electronic
components is done by automated equipment, and
personnel never come into contact with the static-
sensitive devices. Solving the ESD problem means
assuring that ESD events do not occur in the equipment
used to manufacture and test electronic components.
R4.2 Static Control in Equipment
R4-2.1 An effective static control program in
equipment starts with grounding all materials that might
come close to, or in contact with the static sensitive
components. This prevents the generation of static
charge on machine components and eliminates them as
a source of the charge creating ESD events. Care must
be taken in a grounding program to assure that moving
equipment parts remain grounded when they are in
6 Levit, L. et al, “It’s the Hardware. No, Software. No, It’s ESD! ”,
Solid State Technology, May 1999, Pennwell Publishing Company,
98 Spit Brook Road, Nashua NH 03062.
motion. In some cases, static dissipative materials may
be substituted for conductive materials where
flexibility, thermal insulation, or other properties not
available in conductive materials are needed. If
charging of components is unavoidable, static
dissipative materials may be used to slow the resulting
discharges and prevent component damage.
R4-2.2 Most semiconductors use insulating packaging
materials such as ceramics and epoxy. Handling these
insulating materials inevitably generates static charge,
and this charge cannot be removed by grounding the
materials. If charge generation is unavoidable, the only
effective method of neutralizing the charge on
insulators or isolated conductors is to use air ionization.
Ionizers are typically mounted in the load stations and
process chambers of the automated equipment to
neutralize the static charge.
R4-3 Verifying Equipment Static Control
R4-3.1 A static control program begins when the
automated equipment is designed by the OEM, and then
continues throughout the lifetime of the equipment.
Two basic issues need to be demonstrated. First, are all
components in the product-handling path connected to
ground? Second, as the product passes through the
equipment, is it handled in a way that does not generate
static charge above an acceptable level on the
component? ESD Association Standard Practice,
EOS/ESD SP 10.1-1999
7
. This document contains test
methods to verify the integrity of the ground path to
equipment parts, as well as to determine if the product
is being charged during its passage through the
equipment. The test methods are applicable during the
original design of the equipment and during acceptance
testing by the end user.
R4-3.2 While the test methods of EOS/ESD SP10.1-
1999 can also be used for periodic verification of the
equipment performance, they have one drawback. The
automated equipment must be taken off-line to do the
testing. This means that there is lost production time,
and often the periodic testing is eliminated to maintain
product throughput. Other test methods are available
7 EOS/ESD SP10.1 - 1999 “Standard Practice for Protection of
Electrostatic Discharge Susceptible Items - Automated Handling
Equipment”, ESD Association, 700 Turin Road, Rome NY 13440.
SEMI E43-0301 © SEMI 1995, 200117
that can be performed with the equipment operating on-
line, without altering or disturbing its operation.
R4-4 ESD and EMI
R4-4.1 When ESD occurs, the discharge time is
usually 10 nanoseconds or less. Discharging energy in
this short time interval results in the generation of
broadband electromagnetic radiation
8
, as well as the
heat that damages semiconductor components. This
electromagnetic radiation, especially in the 10 MHz to
2 GHz frequency range, is the EMI that can affect the
operation of production equipment. In addition to ESD
damage to semiconductor devices and reticles, ESD-
caused EMI results in a variety of equipment operating
problems including stoppages, software errors, testing
and calibration inaccuracies, and mishandling causing
physical component damage.
R4-4.2 EMI Locators
R4-4.2.1 When component damage or equipment
problems due to ESD are suspected, it may be useful to
detect the electromagnetic interference (EMI) generated
by the ESD event. This type of testing is both a starting
point for determining that static charge has been
generated, and it is a measurement point to ascertain
that any static control methods have been successful.
EMI locators measure dynamic operating conditions, as
it is usually not necessary to interrupt equipment
operations to make measurements.
R4-4.3 Types of EMI Locators
R4-4.3.1 EMI locators are available in a number of
different forms. In its simplest form, it consists of an
AM radio tuned off station. A popping noise will be
heard when an ESD event occurs. At the most complex
it consists of a wideband (greater than 1 GHz) digital
storage oscilloscope with a set of appropriate antennas,
probes, and software. Measurements of radiated
interference can be made using antennas while probes
can be connected to equipment parts or electronics and
power lines.
R4-4.3.2 An oscilloscope attached to a single antenna
can assist in pinpointing the actual location of the ESD
event.
8, 9, 10, 11
A set of antennas can be used to not only
8 Tonoya, Watanabe and Honda, “Impulsive EMI Effects from ESD
on Raised Floor,” 1994 EOS/ESD Symposium, pp. 164-169, ESD
Association.
9 Takai, Kaneko and Honda, “One of the Methods of Observing ESD
Around Electronic Equipments,” 1996 EOS/ESD Symposium, pp.
186-192, ESD Association.
10 Greason, Bulach and Flatley, “Non-Invasive Detection and
Characterization of ESD Induced Phenomena in Electronic Systems,”
1996 EOS/ESD Symposium, pp. 193-202, ESD Association.
11 Smith, “A New Type of Furniture ESD and Its Implications,” 1993
EOS/ESD Symposium, pp. 3-7, ESD Association.
detect the presence of an ESD event, but to determine
the location of the pulse in 3 dimensions.
12, 13
Using the
same concept as a global positioning system (GPS), the
difference in the arrival times of the signal to multiple
antennas is directly related to the difference in the
distance of each antenna from the ESD source. With the
time deltas and the locations of the antennas known, the
location of the spark can be uniquely identified
employing the appropriate analysis program.
R4-4.3.3 Several other types of EMI locating
equipment are currently in use. Most consist of high
frequency receiving circuitry followed by level
detectors to determine the magnitude of the signal. For
the purpose of detecting EMI from ESD events, the
equipment should have some way of differentiating the
short impulse of EMI from the ESD event from the
continuous high frequency radiation of other EMI
sources. Some instruments contain a counter to total
the number of ESD events above the threshold, or
alarms to indicate when the number of ESD events
exceeds a preset number. This type of instrument can be
placed near a piece of equipment that is suspected of
causing ESD events and left in place to monitor.
R4-4.3.4 Several EMI Locators are battery-operated
handheld devices that can be easily carried around a
facility or placed directly in equipment to check for
ESD events. This allows the Locator to detect signals
that might otherwise be shielded by the equipment’s
cover panels. (Note that EMI shielding is usually an
important part of the design of most production
equipment to prevent radiation from the equipment.
This makes the detection of ESD events outside the
equipment more difficult.) It allows pinpointing of the
location of an ESD event, which can then be correlated
to particular machine operations.
8, 14
R4-4.4 Limitation in Using EMI Locators
R4-4.4.1 One caution needs to be observed when using
EMI locators to detect ESD events that cause
component damage. The signal received by these
devices is generated in areas usually surrounded by
grounded metal components. It may have to pass
through equipment panels and travel some distance
through the air before it reaches the detector. There may
12 Bernier, Croft, and Lowther “ESD Sources Pinpointed by Analysis
of Radio Wave Emissions,” Journal of Electrostatics (44) pp. 149-
157, Nov. 1998, Elsevier Science B.V., P.O. Box 211, 1000 AE
Amsterdam Netherlands.
13 Lin, DeChiaro and Jon, “A Robust ESD Event Locator System
with Event Characterization,” 1997 EOS/ESD Symposium, pp. 88-98,
ESD Association.
14 Fujie, A., “Pinpointing Sources of Static Electricity with EMI
Locator”, Parts 1 and 2, Nikkei Electronics Asia, December 1992 and
January 1993, Nikkei Business Publications Asia Ltd., 533 Hennessy
Road, Causeway Bay, Hong Kong.
SEMI E43-0301 © SEMI 1995, 2001 18
be other radio frequency sources and reflecting or
absorbing materials in the area. The actual location of
the ESD event may be a considerable distance from the
EMI locator. It will be difficult to establish any
correlation between the amplitude of the signal received
by the EMI locator and the energy in the ESD event
that produced the signal. The EMI locator primarily
indicates the occurrence of an ESD event and can be
used to illustrate that a particular static control method
has eliminated it. It should not be assumed that every
ESD event detected results in damage to components or
equipment problems. Additional testing will be needed
to establish that connection.
R4-5 Static Event Detectors
R4-5.1 Static event detectors (SED) are devices that
are installed directly on products to detect the presence
of an ESD event. They may be attached in proximity to
an ESD-sensitive component, connected to the external
device leads, or integrated into the device package.
Typically they detect the current pulse of an ESD event
through an antenna or direct connection to the device
circuitry.
R4-5.2 SEDs can be useful in determining the
occurrence of ESD events in operating production
equipment. The SED has the ability to indicate ESD
events of a known level, aiding in the design and
performance verification of automated equipment.
While costly analysis of failed devices can also provide
this information, correlation to machine operations is
usually difficult. An SED that can be monitored
optically as it passes through operating equipment
provides a convenient method to verify that automated
equipment is not generating levels of static charge that
result in ESD damage.
R4-5.3 Types of SED Devices
R4-5.3.1 In some SED devices, the signal is amplified
and processed to produce a reflectance change in the
built-in Liquid Crystal Display (LCD). The SED is
designed to trip at a predetermined threshold voltage,
detecting ESD transients above the selected amplitude.
Some devices can be reset magnetically or optically
making them reusable.
R4-5.3.2 Other devices use the controllable ESD
damage threshold of metal oxide semiconductor field
effect transistors (MOSFET). The test methodology is
to amplify an ESD transient to create sufficient energy
to destroy the gate oxide. The device may be used until
the specified ESD level is achieved, and then the SED
fails. A similar device is based on the metal oxide
semiconductor capacitor (MOSCAP). The current
leakage through the device significantly increases if the
ESD amplitude is sufficient to damage the MOS
structure. Both of these types of SED must be removed
from where they are installed and require additional
instrumentation to determine their status.
R4-5.3.3 Another type of SED employs the magnetic
fields from a current flow to affect a series of magneto-
optic thin films. The magnetic field from the ESD
current alters the film’s magnetic state and affects the
degree of polarization of visible light reflected from the
film. Varying the distance between the film and the
ESD current-carrying conductor indicates different
thresholds. This SED can be read using a microscope
equipped with a polarizing element and does not need
to be removed from the circuitry to be read. It can be
reset with a magnet.
15
R4-6 Conclusion
R4-6.1 There is little question that static charge
problems continue to result in significant losses in high
technology manufacturing. Increasingly, static control
methods must be applied in the equipment that
produces the product. It will be important to develop
and utilize a range of diagnostic methods and
measurement equipment for ESD in equipment.
NOTICE: SEMI makes no warranties or
representations as to the suitability of the standards set
forth herein for any particular application. The
determination of the suitability of the standard is solely
the responsibility of the user. Users are cautioned to
refer to manufacture's instructions, product labels,
product data sheets, and other relevant literature,
respecting any materials or equipment mentioned
herein. These standards are subject to change without
notice.
By publications of this standard, Semiconductor
Equipment and Materials International (SEMI) takes no
position respecting the validity of any patent rights or
copyrights asserted in connection with any items
mentioned in this standard. Users of this standard are
expressly advised that determination of any such patent
rights or copyrights, and the risk of infringement of
such rights are entirely their own responsibility.
15 Jackson, Tan, and Boehm, “Magneto Optical Static Event
Detector,” 1998 EOS/ESD Symposium, pp.233-244, ESD
Association.
Copyright by SEMI® (Semiconductor Equipment and Materials
International), 3081 Zanker Road, San Jose, CA 95134. Reproduction o
f
the contents in whole or in part is forbidden without express written
consent of SEMI.