SEMI E5-1104 © SEMI 1982, 2004 76 Stream,Function Name (Mnemonic) Direction S2,F35 Link Event Report ( LER) M, H->E,reply Description The purpose of this message is for the host to link n reports to an event (CEID). T…

100%1 / 7923
SEMI E5-1104 © SEMI 1982, 2004 75
Stream,Function Name (Mnemonic) Direction
S2,F32 Date and Time Set Acknowledge (DTA) S,H<-E
Description
Acknowledge the receipt of time and date.
Structure
<TIACK>
Exception
None
Stream,Function Name (Mnemonic) Direction
S2,F33 Define Report (DR) M,H->E,reply
Description
The purpose of this message is for the host to define a group of reports for the equipment.
The type of report to be transmitted is designated by a Boolean “Equipment Constant.” An “Equipment Constant Value” of
“False” means that an “Event Report”(S6,F11) will be sent, and a value of “True” means that an “Annotated Event
Report”(S6,F13) will be sent.If S2,F33 is Multi-block, it must be preceded by the S2,F39/S2,F40 Inquire/Grant transaction.
Structure
L,2
1. <DATAID>
2. L,a # reports
1. L,2 report 1
1. <RPTID
1
>
2. L,b # VIDs this report
1. <VID
1
>
.
.
b.<VID
b
>
a. L,2 report a
1. <RPTID
a
>
2. L,c # VIDs this report
1. <VID
1
>
.
.
c. <VID
c
>
Exception
1. A list of zero-length following <DATAID> deletes all report definitions and associated links. See S2,F35 (Link
Event/Report).
2. A list of zero-length following <RPTID> deletes report type RPTID. All CEID links to this RPTID are also deleted.
Stream,Function Name (Mnemonic) Direction
S2,F34 Define Report Acknowledge (DRA) S,H<-E
Description
Acknowledge or error If an error condition is detected the entire message is rejected (i.e., partial changes are not allowed).
Structure
<DRACK>
Exception
None
SEMI E5-1104 © SEMI 1982, 2004 76
Stream,Function Name (Mnemonic) Direction
S2,F35 Link Event Report (LER) M,H->E,reply
Description
The purpose of this message is for the host to link n reports to an event (CEID). These linked event reports will default to
‘disabled’ upon linking. That is, the occurrence of an event would not cause the report to be sent until enabled. See S2,F37 for
enabling reports.
If S2,F35 is Multi-block, it must be preceded by the S2,F39/S2,F40 Inquire/Grant transaction.
Structure
L,2
1. <DATAID>
2. L,a # events
1. L,2 event 1
1. <CEID
1
>
2. L,b
1. <RPTID
1
>
.
.
b. <RPTID
b
>
.
.
a. L,2 event a
1. <CEID
a
> # RPTIDS this event
2.L,c
1.<RPTID
1
>
.
.
c. <RPTID
c
>
Exception
A list of zero length following CEID deletes all report links to that event.
Stream,Function Name (Mnemonic) Direction
S2,F36 Link Event Report Acknowledge (LERA) S,H<-E
Description
Acknowledge or error If an error condition is detected the entire message is rejected (i.e., partial changes are not allowed).
Structure
<LRACK>
Exception
None
SEMI E5-1104 © SEMI 1982, 2004 77
Stream,Function Name (Mnemonic) Direction
S2,F37 Enable/Disable Event Report (EDER) S,H->E,reply
Description
The purpose of this message is for the host to enable or disable reporting for a group of events (CEIDs).
Structure
L,2
1. <CEED> enable/disable
2. L,n #CEIDs
1. <CEID
1
>
.
.
n. <CEID
n
>
Exception
A list of zero length following <CEED> means all CEIDs.
Stream,Function Name (Mnemonic) Direction
S2,F38 Enable/Disable Event Report Acknowledge (EERA) S,H<-E
Description
Acknowledge or error If an error condition is detected the entire message is rejected, i.e., partial changes are not allowed.
Structure
<ERACK>
Exception
None
Stream,Function Name (Mnemonic) Direction
S2,F39 Multi-block Inquire (DMBI) S,H->E,reply
Description
If a S2,F23 S2,F33, S2,F35, S2,F45, or S2,F49 message is more than one block, this transaction must precede the message.
Structure
L,2
1. <DATAID>
2. <DATALENGTH>
Exception
Stream,Function Name (Mnemonic) Direction
S2,F40 Multi-block Grant (DMBG) S,H<-E
Description
Grant permission to send multi-block message.
Structure
<GRANT>
Exception
None