SEMI S14-0704 © SEMI 2000, 2004 7
• limiting their energy, and
• separating them from combustible materials of
construction and from flammable and combustible
process chemicals. Separation may be by distance
or by barriers.
7.3.3 Equipment in which flammable liquids or gases
are used should be assessed to determine if additional
precautions (e.g., purging) in the electrical design are
necessary.
NOTE 23: NFPA 497 and EN 1127-1 are among the
documents that provide methods for making this assessment.
7.4 Oxidizers
7.4.1 Reducing the quantities or pressures of oxidizing
process chemicals may reduce the fire risk.
7.4.2 The fire risks of oxidizing process chemicals may
also be reduced by limiting those factors described in
Section 6.
7.5 Exhaust, Enclosures and Barriers
7.5.1 Mechanical exhaust may reduce the risk of
damage to the facility, other equipment, or other
portions of the same equipment by limiting the spread
of combustion and decomposition products. The
mechanical exhaust could be provided by the
equipment or by the facility.
7.5.2 Enclosures and barriers within the equipment
may reduce the fire risk by separating the fuels and
oxidizers from each other and from potential sources of
ignition.
7.5.3 These design features may also limit the spread
of fire, reducing both the loss of equipment and the
emission of combustion and decomposition products.
8 Related Documents
8.1 SEMI Standard
SEMI S11 — Environmental, Safety, and Health
Guidelines for Semiconductor Manufacturing Equip-
ment Minienvironments
8.2 NFPA Documents
National Fire Protection Association: NFPA 70 —
National Electric Code (NEC)
National Fire Protection Association: NFPA 318 —
Standard for Protection of Cleanrooms
National Fire Protection Association: NFPA 496 —
Standard for Purged and Pressurized Enclosures for
Electrical Equipment
National Fire Protection Association: NFPA 497 —
Recommended Practice for the Classification of
Flammable Liquids, Gases, or Vapors and of
Hazardous (Classified) Locations for Electrical
Installations in Chemical Process Areas
8.3 CEN/CENELEC Standards
4
EN 1127-1 — Explosive Atmosphere – Explosion
prevention and protection – Part 1 Basic concepts and
methodology
8.4 Other Documents
Building Officials and Code Administrators (BOCA)
5
,
NBC: National Building Code
Factory Mutual System Data Sheet 7-7
6
, Semiconductor
Fabrication Facilities
International Conference of Building Officials (ICBO)
7
,
UBC: Uniform Building Code
International Fire Code Institute
8
, UFC: Uniform Fire
Code
International SEMATECH
9
, Process Compatibility
Parameters for Wet Bench Plastic Materials
(Technology Transfer # 98123623A)
Southern Building Code Congress International
(SBCCI)
10
, SBC: Standard Building: Code
4 European Committee for Standardization (CEN)/European
Committee for Electrotechnical Standardization (CENELEC), Central
Secretariat: rue de Stassart 35, B-1050 Brussels Belgium
5 Building Officials & Code Administrators International, Inc., 4051
West Flossmoor Road, Country Club Hills, IL 60477
6 Factory Mutual, 1301 Atwood Ave. P.O. Box 7500 Johnston R.I.
02919, website: www.fmglobal.com
7 ICBO, 5360 South Workman Mill Rd., Whittier, CA 90601
8 International Fire Code Institute, 5360 South Workman Mill Rd.,
Whittier, CA 90601
9 SEMATECH, 2706 Montopolis Drive, Austin, TX, website:
www.sematech.org
10 SBCCI, 900 Montclair Rd, Birmingham, AL 35213-1206

SEMI S14-0704 © SEMI 2000, 2004 8
APPENDIX 1
RISK ASSESSMENT CRITERIA
NOTICE: The material in this appendix is an official part of SEMI S14 and was approved by full letter ballot procedures on
September 3, 1999 by the North American Regional Standards Committee.
A1-1 The risk assessment should be performed for each identified fire hazard using the method provided in SEMI
S10 and the following definitions of Likelihood and Severity Groupings and Risk Categories.
NOTE A1-1: Unlike SEMI S10, in which the tables are provided only as examples, this document defines the Severity,
Likelihood, and Risk to be used herein.
A1-2 Severity
A1-2.1 The Severity Groupings are given in Table A1-1.
Table A1-1 Severity Groupings
Severity Group
Equipment Physical
Damage
Equipment Loss
of Use
Facility Loss of
Use (Minimum
Times)
Environmental and Real Property
Contamination
1 Catastrophic Loss of entire piece of
equipment
One year One week Lasting facility or environmental
impact
2 Severe Loss of major
subsystem
One month One day Temporary facility or environmental
impact
3 Moderate Loss of minor
subsystem
One week One shift Limited to the equipment, but
requiring more than routine cleanup
4 Minor Non-serious
equipment loss
One day Less than one
shift
Requiring routine cleanup but not
external reporting
A1-2.2 The Severity should be assigned for each of the columns for which information is available.
A1-2.3 The most severe Group assigned should be used in determining the risk.
A1-2.4 Each of the Severities should be reported.
A1-2.5 Contamination is by release of materials that were used in the equipment or by combustion or thermal
degradation byproducts.
A1-2.6 To be included in the assessment, a foreseen occurrence must be unplanned and include a loss.
A1-2.7 Losses exclude the performance of the design function of protective devices, such as fuses.
A1-2.8 The scope of the assessment in this document is limited to the consequences of fire.
A1-2.9 The Equipment Loss of Use time is the downtime, as defined in SEMI E10, resulting from the fire incident.
A1-3 Likelihood
A1-3.1 The Likelihood Groupings are given in Table A1-2.
Table A1-2 Likelihood Groupings
Likelihood Group Expected Frequency (% of Systems per Year)
A Frequent More than 1%
B Likely More than 0.2% but not more than 1%
C Possible More than 0.04%, but not more than 0.2%
D Rare More than 0.02%, but not more than 0.04%
E Unlikely Not more than 0.02%

SEMI S14-0704 © SEMI 2000, 2004 9
A1-3.2 “System” refers to the equipment as configured and offered by the supplier.
A1-4 Risk
A1-4.1 The Risk should be calculated based on the Severity and Likelihood assigned above and the Risk Categories
defined in Table A1-3.
Table A1-3 Risk Categories
Likelihood
Severity A B C D E
1 Critical Critical High Medium Low
2 Critical High Medium Low Low
3 High Medium Low Low Slight
4 Medium Low Low Slight Slight
A1-4.2 The Risks are to be reported in total for the equipment as offered for sale. (e.g., if the equipment being
evaluated is a cluster tool, the risks should be reported by the system integrator for the assembled tool, not the
individual modules.)
NOTE A1-2: Although the risks for cluster tools should be reported for the assembled tool, the modules are not necessarily
contiguous and this may bear on the risk.
NOTE A1-3: The Risks of components or subsystems may be increased or decreased by their integration into the equipment
being assessed.