semi合集-English.pdf - 第2122页
SEMI E54.14-0305 © SEMI 2005 16 http://www.PROFIBUS.com/support.html 5 ). Certified products are listed with their certificate number in the Electronic Pro duct Guide. 8.2 GSD files of all PROFINE T devices that are test…

SEMI E54.14-0305 © SEMI 2005 15
Table 16 Active Element Service Mapping
SEMI CDM Service ID Service Write Value to Index 64
nS4 Get Attribute Mapped as Read from Attribute Index
nS5 Set Attribute Mapped as Write to Attribute Index
nS1 Reset 0
nS2 Abort 1
nS3 Recover 2
nS6 Operate 3
nS7 Restore Default 4
7.7 PROFINET Device Data Base
7.7.1 The specification of the Device Data Base (or GSD file) for a given SDM is beyond the scope of this
document. The PROFIBUS Trade Organization is responsible for the management of these files.
Table 17 DM Object Attribute Identifiers
SEMI CDM
Attribute ID
PROFINET Attribute ID Attribute Detail/Alternative Access Method
DmA1 IM0, DEVICE_ID Device Type 8 Octets significant
DmA2 IM0, REVISION_COUNTER Standard Revision Level Shall be an UINT type
DmA3 IM0, MANUFACTURER_ID Device Manufacturer Identifier Shall be an UINT type, the number
is resolved via file from
www.profibus.com to supply with
web pages and phone numbers
DmA4 IM0, ORDER_ID Manufacturer Model Number
DmA5 IM0, SOFTWARE_REVISION Software or Firmware Revision Level
DmA6 IM0, HARDWARE_REVISION Hardware Revision Level
DmA7 IM0, SERIAL_NUMBER Serial Number 16 Octets maximum
DmA8 IM3 Device Configuration
DmA9 IM17, octet 10-11 Device Status Additional as Status Diagnosis
DmA10 IM16, octet 10-11 Reporting Mode
DmA11 IM16, octet 12-13 Exception Status Report Interval
DmA12 IM17, octet 12-13 Exception Status Additional as Status Diagnosis
DmA13 Slot 0 Index 0xe00b Exception Detail Alarm Additional as Diagnosis Alarm
DmA14 Slot 0 Index 0xe00b Exception Detail Warning Additional as Diagnosis Alarm
DmA15 Optional Attribute not mapped Visual Indicator N/A
DmA16 Context Alarm Enable Put into a Parameter Data Record
DmA17 Context Warning Enable Put into a Parameter Data Record
DmA18 Optional Attribute not mapped Exception Detail Type N/A
DmA19 Optional Attribute not mapped Exception Detail Alarm Queue N/A
DmA20 Optional Attribute not mapped Exception Detail Warning Queue N/A
DmA21 Optional Attribute not mapped Date and Time N/A
DmA22 Optional Attribute not mapped Date and Time Type N/A
DmA23-
DmA31
Reserved Reserved N/A
8 Protocol Compliance
8.1 PROFIBUS International has established a qualified certification system, with test laboratories in Europe, Asia
and North America, which includes conformance testing and interoperability testing (address list can be found at

SEMI E54.14-0305 © SEMI 2005 16
http://www.PROFIBUS.com/support.html
5
). Certified products are listed with their certificate number in the
Electronic Product Guide.
8.2 GSD files of all PROFINET devices that are tested for their conformity to the PROFIBUS standard are
available in the GSD library on the World Wide Web Server of the PROFIBUS User Organization at
http://www.PROFIBUS.com.
9 Specific Device Model Mappings
9.1 Every type of device shall have an identifier number. Vendors must apply for an identifier number from the
PROFIBUS User Organization. A Device Profile shall be submitted in the form of a GSD File and Device Data
Base Sheet.
9.2 The Device Profile must specify the identifiers for Objects, Attributes and Services for CDM and SDM
components, including data formats and bit mappings for specified parameters, as represented in this document.
9.3 The following sections specify mappings for Sensor Actuator Network Specific Device Models.
9.4 Mass Flow Device
9.4.1 Reference SEMI E54.3 for a complete specification of the SDM for Mass Flow Devices (MFD).
9.4.2 Objects
9.4.2.1 Consistent with SEMI E54.3 and ¶7.4 above, the DM and SAC objects are identified as Object 1 and Object
2, respectively.
9.4.2.2 Notice that references for the Local Link Objects are not included; the existence of these objects are implied
by behavior and not explicitly included. Therefore, these objects are not accessible from the network.
9.4.2.3 Table 18 shows the mapping of the SDM.
9.4.2.4 Objects specified in SEMI E54.3 are listed under the heading NCS Module ID. Every instance is allocated
to a slot number. The configuration can be modeled in the GSD by using the Module ID as key for the module
description.
Table 18 Mass Flow Device Object Identifiers
SDM Object
Name
SDM Object ID NCS Module ID
Sensor-AI-MF MFD3 103
Sensor-AI-AT MFD4 104
Assembly-MFM MFD5 105
Sensor-AI-Aux MFD6 106
Actuator-AO-MF MFD7 107
Controller MFD8 108
Local Link MFD9 109
SISO MFD10 110
SISO-Setpoint MFD11 111
Assembly-MFC MFD12 112
9.4.3 Attributes
9.4.3.1 The mapping of Attribute Tags and Identifiers is defined in §7 for SAC. The same method applies here for
the SDM.
9.4.3.2 Tables 19–23 show the mapping of the specific SDM attributes.
5 Website maintained by PROFIBUS International.

SEMI E54.14-0305 © SEMI 2005 17
Table 19 Sensor AI-MF Object Attribute Identifiers
SEMI SDM
Attribute ID
PROFINET
Index
Attribute
A1 160 Flow Totalizer
A2 161 Flow Hours
A5 164 Zero Offset Mode
A6 165 Zeroing Status
A7 166 Autorange Status
Table 20 Actuator AO-MF Object Attribute Identifiers
SEMI SDM
Attribute ID
PROFINET
Index
Attribute
A1 160 Valve Type
A2 161 Override
Table 21 Controller Object Attribute Identifiers
SEMI SDM
Attribute ID
PROFINET
Index
Attribute
A1 160 Valve Type
A2 161 Override
Table 22 SISO Object Attribute Identifiers
SEMI SDM
Attribute ID
PROFINET
Index
Attribute
A1 65 Input
A2 66 Output
A3 67 Data Type
Table 23 SISO Setpoint Object Attribute Identifiers
SEMI SDM
Attribute ID
PROFINET
Index
Attribute
A33 97 Ramp Type
A34 98 Ramp Rate
A35 99 Ratio
9.4.4 Services
9.4.4.1 The mapping of Service Tags and Identifiers is defined in §7 for SAC. The same method applies here for
the SDM.