SEMI E43-0301 © SEMI 1995 , 2001 16 RELATED INFORM A TI ON 4 OTHER METHODS FOR DETECTING STA TIC CHARGE AND ESD EVENTS IN EQUIPMENT NOT E: T his relate d information is not an off icial part of this standa rd. How ever, …

SEMI E43-0301 © SEMI 1995, 200115
standard requirements. The IEC 61000-4-2, 1996
(formally-801-2,1992) standard uses direct contact or
air discharge to the system under test and is a different
procedure from the other three procedures mentioned
above. Calibration before use requires the use of a very
large vertical ground plane (at least 4 ft by 4 ft square),
a high BW current probe, cables and high bandwidth
waveform recorder/digitizer.
R3-3 Industry Classifications
R3-3.1 HBM classification
1. < 250 volts
2. 250 to < 500
3. 500 to < 1000
4. 1000 to < 2000
5. 2000 to < 4000
6. 4000 to < 8000
7. = or > 8000
R3-3.2 MM classification
1. M1 < 100
2. M2 100 to < 200
3. M3 200 to < 400
4. M4 400 to < 800
5. M5 = or > 800
R3-3.3 CDM classification
1. C1 < 125
2. C2 125 to < 250
3. C3 250 to < 500
4. C4 500 to < 1000
5. C5 1000 to < 2000
6. C6 = or > 2000
R3-3.4 Hand-Held Metal HBM classification
Direct Contact Discharge
Voltage Current
1. 2,000 12.0 amps
2. 4,000 24.0
3. 6,000 36.0
4. 8,000 48.0
Air Discharge
Voltage Current
1. 2,000 15.0 amps
2. 4,000 25.0
3. 6,000 30.0
4. 10,000 35.0
5. 15,000 52.0
Note that the currents for the same voltage level are not
the same for contact versus air discharge.

SEMI E43-0301 © SEMI 1995, 2001 16
RELATED INFORMATION 4
OTHER METHODS FOR DETECTING STATIC CHARGE AND ESD
EVENTS IN EQUIPMENT
NOTE: This related information is not an official part of this standard. However, it contains relevant information for using the
standard in situations commonly encountered with semiconductor manufacturing facilities and equipment. Determination of the
suitability of the material is solely the responsibility of the user.
R4-1 Introduction
R4-1.1 Static charge generation is unavoidable
whenever materials come in contact. Without a static
control program, the problems caused by static charge
are also unavoidable. The most common problem
caused by static charge is electrostatic discharge (ESD).
ESD results in damaged semiconductor ICs, photomask
defects, magneto-resistive (MR) read head defects in
disk drives, and failures of the drive circuits for flat
panel displays (FPD). ESD also creates a significant
amount of electromagnetic interference (EMI). Often
mistaken for software errors, EMI resulting from ESD
interrupts the operation of production equipment. This
is particularly true of equipment depending on high-
speed microprocessors for control. Results include
unscheduled downtime, increased maintenance
requirements, and frequently, product scrap.
Technology trends to smaller device geometries, faster
operating speeds, and increased circuit density make
ESD problems worse.
6
R4-1.2 For many years static control programs
concentrated on protecting components from the charge
generated on the personnel that handled them. Many
static control methods were devised to control the
charge on people including wrist and heel straps,
dissipative shoes and flooring, and garments.
Increasingly, however, the production of electronic
components is done by automated equipment, and
personnel never come into contact with the static-
sensitive devices. Solving the ESD problem means
assuring that ESD events do not occur in the equipment
used to manufacture and test electronic components.
R4.2 Static Control in Equipment
R4-2.1 An effective static control program in
equipment starts with grounding all materials that might
come close to, or in contact with the static sensitive
components. This prevents the generation of static
charge on machine components and eliminates them as
a source of the charge creating ESD events. Care must
be taken in a grounding program to assure that moving
equipment parts remain grounded when they are in
6 Levit, L. et al, “It’s the Hardware. No, Software. No, It’s ESD! ”,
Solid State Technology, May 1999, Pennwell Publishing Company,
98 Spit Brook Road, Nashua NH 03062.
motion. In some cases, static dissipative materials may
be substituted for conductive materials where
flexibility, thermal insulation, or other properties not
available in conductive materials are needed. If
charging of components is unavoidable, static
dissipative materials may be used to slow the resulting
discharges and prevent component damage.
R4-2.2 Most semiconductors use insulating packaging
materials such as ceramics and epoxy. Handling these
insulating materials inevitably generates static charge,
and this charge cannot be removed by grounding the
materials. If charge generation is unavoidable, the only
effective method of neutralizing the charge on
insulators or isolated conductors is to use air ionization.
Ionizers are typically mounted in the load stations and
process chambers of the automated equipment to
neutralize the static charge.
R4-3 Verifying Equipment Static Control
R4-3.1 A static control program begins when the
automated equipment is designed by the OEM, and then
continues throughout the lifetime of the equipment.
Two basic issues need to be demonstrated. First, are all
components in the product-handling path connected to
ground? Second, as the product passes through the
equipment, is it handled in a way that does not generate
static charge above an acceptable level on the
component? ESD Association Standard Practice,
EOS/ESD SP 10.1-1999
7
. This document contains test
methods to verify the integrity of the ground path to
equipment parts, as well as to determine if the product
is being charged during its passage through the
equipment. The test methods are applicable during the
original design of the equipment and during acceptance
testing by the end user.
R4-3.2 While the test methods of EOS/ESD SP10.1-
1999 can also be used for periodic verification of the
equipment performance, they have one drawback. The
automated equipment must be taken off-line to do the
testing. This means that there is lost production time,
and often the periodic testing is eliminated to maintain
product throughput. Other test methods are available
7 EOS/ESD SP10.1 - 1999 “Standard Practice for Protection of
Electrostatic Discharge Susceptible Items - Automated Handling
Equipment”, ESD Association, 700 Turin Road, Rome NY 13440.

SEMI E43-0301 © SEMI 1995, 200117
that can be performed with the equipment operating on-
line, without altering or disturbing its operation.
R4-4 ESD and EMI
R4-4.1 When ESD occurs, the discharge time is
usually 10 nanoseconds or less. Discharging energy in
this short time interval results in the generation of
broadband electromagnetic radiation
8
, as well as the
heat that damages semiconductor components. This
electromagnetic radiation, especially in the 10 MHz to
2 GHz frequency range, is the EMI that can affect the
operation of production equipment. In addition to ESD
damage to semiconductor devices and reticles, ESD-
caused EMI results in a variety of equipment operating
problems including stoppages, software errors, testing
and calibration inaccuracies, and mishandling causing
physical component damage.
R4-4.2 EMI Locators
R4-4.2.1 When component damage or equipment
problems due to ESD are suspected, it may be useful to
detect the electromagnetic interference (EMI) generated
by the ESD event. This type of testing is both a starting
point for determining that static charge has been
generated, and it is a measurement point to ascertain
that any static control methods have been successful.
EMI locators measure dynamic operating conditions, as
it is usually not necessary to interrupt equipment
operations to make measurements.
R4-4.3 Types of EMI Locators
R4-4.3.1 EMI locators are available in a number of
different forms. In its simplest form, it consists of an
AM radio tuned off station. A popping noise will be
heard when an ESD event occurs. At the most complex
it consists of a wideband (greater than 1 GHz) digital
storage oscilloscope with a set of appropriate antennas,
probes, and software. Measurements of radiated
interference can be made using antennas while probes
can be connected to equipment parts or electronics and
power lines.
R4-4.3.2 An oscilloscope attached to a single antenna
can assist in pinpointing the actual location of the ESD
event.
8, 9, 10, 11
A set of antennas can be used to not only
8 Tonoya, Watanabe and Honda, “Impulsive EMI Effects from ESD
on Raised Floor,” 1994 EOS/ESD Symposium, pp. 164-169, ESD
Association.
9 Takai, Kaneko and Honda, “One of the Methods of Observing ESD
Around Electronic Equipments,” 1996 EOS/ESD Symposium, pp.
186-192, ESD Association.
10 Greason, Bulach and Flatley, “Non-Invasive Detection and
Characterization of ESD Induced Phenomena in Electronic Systems,”
1996 EOS/ESD Symposium, pp. 193-202, ESD Association.
11 Smith, “A New Type of Furniture ESD and Its Implications,” 1993
EOS/ESD Symposium, pp. 3-7, ESD Association.
detect the presence of an ESD event, but to determine
the location of the pulse in 3 dimensions.
12, 13
Using the
same concept as a global positioning system (GPS), the
difference in the arrival times of the signal to multiple
antennas is directly related to the difference in the
distance of each antenna from the ESD source. With the
time deltas and the locations of the antennas known, the
location of the spark can be uniquely identified
employing the appropriate analysis program.
R4-4.3.3 Several other types of EMI locating
equipment are currently in use. Most consist of high
frequency receiving circuitry followed by level
detectors to determine the magnitude of the signal. For
the purpose of detecting EMI from ESD events, the
equipment should have some way of differentiating the
short impulse of EMI from the ESD event from the
continuous high frequency radiation of other EMI
sources. Some instruments contain a counter to total
the number of ESD events above the threshold, or
alarms to indicate when the number of ESD events
exceeds a preset number. This type of instrument can be
placed near a piece of equipment that is suspected of
causing ESD events and left in place to monitor.
R4-4.3.4 Several EMI Locators are battery-operated
handheld devices that can be easily carried around a
facility or placed directly in equipment to check for
ESD events. This allows the Locator to detect signals
that might otherwise be shielded by the equipment’s
cover panels. (Note that EMI shielding is usually an
important part of the design of most production
equipment to prevent radiation from the equipment.
This makes the detection of ESD events outside the
equipment more difficult.) It allows pinpointing of the
location of an ESD event, which can then be correlated
to particular machine operations.
8, 14
R4-4.4 Limitation in Using EMI Locators
R4-4.4.1 One caution needs to be observed when using
EMI locators to detect ESD events that cause
component damage. The signal received by these
devices is generated in areas usually surrounded by
grounded metal components. It may have to pass
through equipment panels and travel some distance
through the air before it reaches the detector. There may
12 Bernier, Croft, and Lowther “ESD Sources Pinpointed by Analysis
of Radio Wave Emissions,” Journal of Electrostatics (44) pp. 149-
157, Nov. 1998, Elsevier Science B.V., P.O. Box 211, 1000 AE
Amsterdam Netherlands.
13 Lin, DeChiaro and Jon, “A Robust ESD Event Locator System
with Event Characterization,” 1997 EOS/ESD Symposium, pp. 88-98,
ESD Association.
14 Fujie, A., “Pinpointing Sources of Static Electricity with EMI
Locator”, Parts 1 and 2, Nikkei Electronics Asia, December 1992 and
January 1993, Nikkei Business Publications Asia Ltd., 533 Hennessy
Road, Causeway Bay, Hong Kong.