SEMI F41-0699 © SEMI 1999 3 purity chemical flus hed t o drain during the qu ali ficat ion process, this approach m ay also prove to be m ore cost effective depending on the cost of the chemical used for pickling, compar…

SEMI F41-0699 © SEMI 1999 2
4.2.1 SIA National Technology Roadmap For Process
Chemicals
1
5 Terminology
5.1 Acronyms and Abbreviations
5.1.1 BCDS — Bulk Chemical Distribution System
5.2 Definitions
5.2.1 pickling — To condition the BCDS by exposing
to an aggressive chemical that extracts impurities from
the internal surfaces of the system.
5.2.2 sample — Sample taken from a system into a
sampling container and measured off-line.
6 Pre-Chemical Qualificatio n
6.1 Advantage of Pre-Chemical Qualification — The
pre-chemical qualification is designed to ensure that the
piping systems and storage tanks are able to accept
chemicals. This step is often initiated after the UPW
system is functional and an acceptable resistivity is
achieved but before chemicals are authorized to be
brought on-site. Although UPW does not extract high
levels of metallic and ionic impurities from the BCDS
materials of construction, this step can ensure that the
BCDS and distribution piping is free of any gross
contamination that may have been introduced into the
system during installation. In addition, the UPW flush
can be effective for the elimination of some types of
particles.
6.2 Particle Qualification The BCDS is flushed
with UPW and the levels of particles are measured
using an on-line optical particle counter. The steps
followed include:
6.2.1 Install an acceptable UPW water filter element(s)
per the filter and BCDS manufacturer's specifications.
6.2.2 Fill the BCDS with UPW and recirculate
internally to ensure that all piping is filled with UPW.
6.2.3 Begin sampling to a liquid particle counter
downstream of the filters either at the outlet of the
BCDS, the POU, or both. Follow an approved particle
counting sampling procedure.
6.2.4 Continue recirculating and flushing until the
particle concentrations in the desired channel or
channels are observed at levels below the agreed-upon
specification. An example of typical specification is the
average of five consecutive ten minute readings of <X
particles/ml @ ≥ Y micron.
1
Semiconductor Industry Association, 181 Metro Drive, Ste 150, San Jose, CA
95110, USA
6.3 Metallic Qualification After reaching the
particle specification for the UPW, a sample of UPW
may be taken for trace metal analysis. This sample can
be taken at the outlet of the BCDS, at an end point
sample station and/or at the POU. An appropriate
sample bottle precleaned for this test should be used to
collect a sample. The sample bottle should be
preconditioned before use and contamination-free
techniques used for the actual sampling.
6.3.1 The steps to follow are:
6.3.1.1 Fill the sample bottle with the required volume
for the analytical method to be used. The volume varies
depending on analytical procedures and lab
instrumentation.
6.3.1.2 Send samples to a designated laboratory
capable of performing trace metal analysis. Use only a
laboratory that has experience with these types of
samples and that can test reliably in the sub-ppb range.
The number of elements and concentrations that are to
be analyzed will vary depending on customers’
requirements.
6.3.1.3 Evaluate data and compare to the agreed-upon
specification. A typical specification is <X ppb total
and <X ppb per element.
6.3.1.4 If the trace metal specification is not met, drain
or flush the entire BCDS and distribution piping and
repeat the process.
6.3.1.5 If a maximum level of impurities is desired, a
sample of the UPW used to charge the system should be
tested to establish a baseline and to ensure that the
incoming UPW is not the source of high impurities.
6.3.1.6 Once the BCDS has been qualified for particles
and trace metals in UPW, the qualification of the BCDS
in Chemical may be initiated.
7 Chemical Conditioning of The System
7.1 Advantages of Conditioning the System
Another precleaning step that may be used
independently or in conjunction with a UPW flush is to
condition the BCDS by actively flushing it with an
aggressive chemical that extracts impurities from the
internal surfaces of the system. This step is sometimes
referred to as "pickling" the system. This extra step can
help minimize the amount of time consumed in the
qualification process by utilizing a chemical with more
aggressive extraction properties than the actual
chemical to be used in the line, thereby increasing the
rate at which impurities are removed. This can shorten
the amount of time needed until the actual chemical can
be put into the line and shown to meet the qualification
specifications. Since a goal of a well-designed
qualification protocol is to minimize the amount of high

SEMI F41-0699 © SEMI 19993
purity chemical flushed to drain during the qualification
process, this approach may also prove to be more cost
effective depending on the cost of the chemical used for
pickling, compared to the cost of the process chemical
designated for use in the line.
7.2 Conditioning With Same Chemical A variation
on the above approach is to "pickle" the system with the
process chemical that is intended to be used in the
BCDS line a 24-72 hour soak period and flushing the
chemical to drain. While the process chemical may not
be as aggressive in cleaning up the line, this approach
has the advantage that the extracted metals have the
same fingerprint as those that might otherwise be
observed during the final qualification testing, and the
final qualification may be done immediately following
this step, without further preparation.
7.3 Testing the Preconditioning Chemical Rather
than relying on an arbitrary or predetermined lengths of
time for preconditioning the BCDS, test samples are
often taken and analyzed to ensure that the required
level of impurities has actually been obtained. This
testing is often commissioned by the equipment
manufacturer and not reported to the customer as part of
the BCDS qualification. Indicator elements are often
analyzed that are either of particular concern in the
process chemical, or elements such as Ca, Cr, Cu, Fe,
Mg, Na, Ni, and Zn, that are known as common
impurities in chemicals and that are also highly
detrimental in semiconductor processing.
7.4 Conditioning Procedure The three most
common chemicals (HCL, HF, and HNO3) used for
precleaning the BCDS are aggressive in extracting
metallic impurities and particles. The steps followed
include:
7.4.1 Install an acceptable chemical filter element(s)
per the filter and BCDS manufacturer's specifications.
7.4.2 Fill the BCDS and distribution piping with the
chemical of choice and recirculate internally to ensure
that all piping is filled. This may include all
distribution piping. Let the chemical soak the materials
of construction in a static manner for a period of 24 to
72 hours, or continue recirculating the chemical as a
closed loop for the same amount of time.
7.4.3 Flush the chemical from the system.
7.4.4 Depending on the chemical used, a UPW rinse
step or an inert gas purge step for drying may be
required prior to filling the system with the actual
chemical for the qualification testing.
Note: The precleaning chemicals used may add
undesirable contaminants (i.e. F
-
from Hydrofluoric
acid, Cl
-
from hydrochloric acid, etc.). Therefore, if
any of these chemicals are used, additional testing may
be required to determine that these materials have not
added contaminants in excess of any specification.
These contaminants may be tested in the UPW rinse
step or in the final chemical qualification step.
7.5 Solvent Systems The type of chemical used for
flushing solvent BCDS systems is different than that
used for oxidizers and corrosive chemicals since solvent
systems can be made from stainless steel and metal
materials for reasons of safety and chemical
compatibility. Generally, IPA, or the chemical to be
used in the system, is used for the aqueous pre-clean
step in flushing a system where solvents are to be used.
8 Final Chemical Qualification
8.1 Initial Considerations Notwithstanding any of
the steps taken to prepare the BCDS for qualification
testing, certain issues should be considered prior to
starting any sampling required in the qualification
process:
8.1.1 Determination about the adequacy of the
sampling points. The sampling points are generally
coincident with the location of pre-existing sample
ports on the Valve Manifold Box, day tank and other
distribution points. The adequacy of the sampling
points depends on their accessibility, environmental
controls, ability to flush prior to sampling, and safety
considerations.
8.1.2 Adequacy of data. Due to sampling error,
possibility of environmental contamination, handling
problems, and impurities in sampling containers,
samples should be taken in duplicate or triplicate, with
two samples sent to the lab for testing and one sample
retained in case of a dispute.
8.1.3 Use of proper precleaned samp ling containers.
Sampling containers must be chemically compatible
and precleaned in a manner consistent with the desired
specification level for impurities. Sample bottle
preparation differs depending on the type of testing to
be performed.
8.1.4 Use of a contamination-free sampling device for
samples pulled from an open vessel or a drum.
8.1.5 Proper training for personnel a ssigned to
sampling. The proper training is required to ensure
that personnel charged with sampling follow
appropriate safety and contamination-free protocols.

SEMI F41-0699 © SEMI 1999 4
8.2 Particle Qualification For most accurate results,
particle levels should be measured on-line with a
optical particle counter capable of measuring the size of
particle that is included in the guaranteed specification.
Batch samples may be taken and measured for particles
in a lab, but special care is needed to prequalify
containers used for this sampling, and data integrity
may be compromised for the smallest sized particles
due to various contamination sources. An example of a
protocol generally followed to measure particle on-line
includes:
8.2.1 Remove all UPW in the BCDS and distribution
piping.
8.2.2 Remove UPW filters or replace incompatible
chemical filters if present.
8.2.3 Install specified filter element per the BCDS and
filter manufacture's specifications.
8.2.4 Commission the BCDS and distribution piping
with the process chemical.
8.2.5 Recirculate chemical through the BCDS and
through all POU to drain.
8.2.6 Drain all chemicals from the BCDS and
distribution piping.
8.2.7 Refill entire system with chemical and begin
circulation through filters and out to POU to drain.
8.2.8 Begin sampling to a liquid par ticle counter
downstream of the filters either at the outlet of the
BCDS, the POU, or both. Follow a prescribed particle
counting sampling procedure.
8.2.9 The number of particle samples and sample
duration time should be calculated based on the total
volume of chemical desired to be examined by the
particle counter. A "sufficient" volume of chemical
should be examined by the particle counter during the
qualification period. As an example, the particle
concentration could be measured over at least a five-
hour period with thirty consecutive ten-minute samples
taken. In this example, the average of the last
consecutive 30 samples would be calculated and
compared to the specification.
8.2.10 The particle concentration is considered
acceptable if the average is less than the specification.
8.3 Metallic Qualification Metallic impurities are
generally specified both in terms of level of impurity by
element and total amount of impurities. The customer's
specification generally lists each element to be included
in the analysis or may refer to the list of elements
published by SEMI for each chemical at different purity
grades. The maximum impurity levels may be
described as an absolute value (e.g. 1ppb maximum
impurity), or in terms of the quantity of impurities that
may be added by the BCDS including the distribution
piping. This amount of "total adders" is determined by
measuring the impurity levels of the incoming chemical
from the storage or supply vessel compared to the
purity level of the chemical at the end point sample
station or POU. The number of samples and location of
samples vary depending on the type of specification.
When qualifying to a “metallic impurities added”
specification, a sample must be taken from the
incoming chemical supply drums for an incoming
baseline. The testing protocols includes:
8.3.1 Precondition all sampling bottles before use and
follow appropriate sampling protocol.
8.3.2 Send samples to a lab for trace metal analysis
specifying the level of testing required and the number
of elements to be tested. The level of testing required
depends on the agreed upon specification. As a rule of
thumb, the detection limits of the analysis should be at
least 10X's lower than the impurity level to be achieved
for each element. In addition, the lab should follow
high standards of quality control for trace metal
analysis including analysis in duplicate, duplicate
blanks, use of internal standards, instrument calibration
using primary standards, and QC checks.
8.3.3 Review the data that is reported and compare it
to the customer requirement.
8.3.4 If the system does not meet the specification
then repeat the procedure until the system is qualified.
8.3.5 Where maximum levels of impurities are
specified, a sample of the incoming chemical should
either be measured as part of the qualification process,
or retained, to ensure that the incoming chemical is not
a significant source of contamination.
8.3.6 For purposes of metallic qualification, soak
periods similar to those referenced in Section 7.2 are
recommended.
9 Other Considerations
9.1 Accelerated Qualification Techniques
Although process chemicals such as hydrofluoric and
hydrochloric acid may reach acceptable levels of purity
after a few weeks in the BCDS, other chemicals such as
sulfuric acid and ammonium hydroxide extract
impurities much more slowly and significant levels of
impurities are observed even after several months. The
BCDS conditioning process described above is one
approach to preleaching impurities from the BCDS.
Other variations include combinations of static and
dynamic rinses and emphasis on the use of dilute HF as
the aqueous preclean chemical that is particularly
effective for iron removal, however, it contributes high