SEMI E54.16-0705 © SEMI 2005 30 Table 35 A ssembly-MFM Object Insta nce Net work Services Assembly-MFM Profile ID = 180.82, Instance ID = 00, 01 Service Request Code Service Name SDM Tag Request Parameters Result Paramet…

SEMI E54.16-0705 © SEMI 2005 29
CMD_INSERT_GAS_TYPE = 132,
CMD_DELETE_GAS_TYPE = 133,
CMD_GET_GAS_CALIBRATION_DATA_VALUE = 135,
CMD_SET_GAS_CALIBRATION_DATA_VALUE = 135,
CMD_AUTORANGE = 136,
} semi_request_t;
typedef struct {
unsigned int flblock_index;
semi_request_t service_code;
unsigned int parameter; // Optional parameter
} SNVT_semi_req;
9.2.5 Sensor-AI-AT — The presentation of the Sensor Analog Input Ambient Temperature (Sensor-AI-AT) object
instance attributes are as indicated in Table 32. The presentation of object services shall be indicated in Table 33.
Table 32 Sensor-AI-AT Object Instance Network Variables
Sensor-AI-AT
Profile ID = 180.12, Instance ID = 00 through r
Sequence
Number
Name Storage Class SDM Tag Standard NV or CP Data Type
-- No Additional Attributes Defined -- --
Table 33 Sensor-AI-AT Object Instance Network Services
Sensor-AI-AT
Profile ID = 180.12, Instance ID = 00 through r
Service
Request Code
Service Name SDM Tag Request Parameters Result Parameters
-- No Additional Services Defined --
9.2.6 Assembly-MFM — The presentation of the Assembly Mass Flow Meter (Assembly-MFM) object instance
attributes are as indicated in Table 34. The presentation of object services shall be indicated in Table 35.
Table 34 Assembly-MFM Object Instance Network Variables
Assembly-MFM
Class ID = 180.82, Instance ID = 00, 01
Sequence
Number
Name Storage Class SDM Tag Standard NV or CP Data Type
1 Data File A1 LonMark file transfer NVs and messaging
interface

SEMI E54.16-0705 © SEMI 2005 30
Table 35 Assembly-MFM Object Instance Network Services
Assembly-MFM
Profile ID = 180.82, Instance ID = 00, 01
Service
Request Code
Service Name SDM Tag Request Parameters Result Parameters
-- No Additional Services Defined --
9.2.7 Sensor-AI-Aux — The presentation of the Sensor Analog Input Auxiliary (Sensor-AI-Aux) object instance
attributes are as indicated in Table 36. The presentation of object services shall be indicated in Table 37.
Table 36 Sensor-AI-Aux Object Instance Network Variables
Sensor-AI-Aux
Profile ID = 180.14, Instance ID = 00 through r
Sequence
Number
Name Storage Class SDM Tag Standard NV or CP Data Type
-- No Additional Attributes Defined -- --
Table 37 Sensor-AI-Aux Object Instance Network Services
Sensor-AI-Aux
Profile ID = 180.14, Instance ID = 00 through r
Service
Request Code
Service Name SDM Tag Request Parameters Result Parameters
-- No Additional Services Defined --
9.2.8 Actuator-AO-MF — The presentation of the Actuator Analog Output Mass Flow (Actuator-AO-MF) object
instance attributes are as indicated in Table 38. The presentation of object services shall be indicated in Table 39.
Table 38 Actuator-AO-MF Object Instance Network Variables
Actuator-AO-MF
Profile ID = 180.32, Instance ID = 00 through r
Sequenc
e
Number
Name Storage Class SDM Tag Standard NV or CP Data Type
128 Valve Type A1 CP Typedef unsigned byte SCPTvalveType(*)
#1
129 Override A2 CP Typedef unsigned byte
SCPTvalveOperatingModeE(*)
#1
#1
: (*) LonMark interoperability extension. Refer to §6.8.3 for further definition.
Table 39 Actuator-AO-MF Object Instance Network Services
Actuator-AO-MF
Profile ID = 180.32, Instance ID = 00 through r
Service
Request Code
Service Name SDM Tag Request Parameters Result Parameters
-- No Additional Services Defined --

SEMI E54.16-0705 © SEMI 2005 31
9.2.9 Controller-C — The presentation of the Controller (C) object instance attributes are as indicated in Table 40.
The presentation of Controller object services are indicated in Table 41.
Table 40 Controller -C Object Instance Network Variables
Controller-C
Profile ID = 180.51, Instance ID = 00, 01
Sequence
Number
Name Storage Class SDM Tag Standard NV or CP Data Type
128 Alarm Settling Time CA21 CP SCPTalrmSetT2
129 Warning Settling Time CA24 CP SCPTalrmSetT1
Table 41 Controller-C Object Instance Network Services
Controller-C
Profile ID = 180.51, Instance ID = 00, 01
Service
Request Code
Service Name SDM Tag Request Parameters Result Parameters
-- No Additional Services Defined --
9.2.10 Local Link-Lnk — The presentation of the Local Link (Lnk) object instance attributes are as indicated in
Table 42. The presentation of Local Link object services are indicated in Table 43.
Table 42 Local Link Object Instance Network Variables
Local Link (Lnk)
Sequence
Number
Name Storage Class SDM Tag Standard NV or CP Data Type
-- No Additional Attributes
Defined
-- --
Table 43 Local Link Object Instance Network Services
Local Link (Lnk)
Service
Request Code
Service Name SDM Tag Request Parameters Result Parameters
-- No Additional Services Defined --
9.2.11 SISO — The presentation of the Single Input Single Output (SISO) object instance attributes are as indicated
in Table 44. The presentation of SISO object services are indicated in Table 45.
Table 44 SISO Object Instance Network Variables
SISO
Profile ID = 180.71, Instance ID = 00 through r
Sequence
Number
Name Storage Class SDM Tag Standard NV or CP Data Type
128 Input NVI A1 Typedef (*)
#1
SNVT_xxx
129 Output NVO A2 Typedef (*)
#1
SNVT_xxx