SEMI E49.7-0304
PURITY GUIDE FOR THE DESIGN AND MANUFACTURE OF
ULTRAPURE WATER AND LIQUID CHEMICAL SYSTEMS IN
SEMICONDUCTOR PROCESS EQUIPMENT
This guide was technically approved by the Global Liquid Chemicals Committee and is the direct
responsibility of the North American Liquid Chemicals Committee. Current edition approved by the North
American Regional Standards Committee on December 4, 2003. Initially available at www.semi.org
February 2004 to be published March 2004. Originally published 1995, last published July 2002.
This standard was editorially modified in January 2004 to correct a typographical error. A change was made
to Section 10.5.4.
1 Purpose
1.1 The objective of this document is to provide
recommendations that will help maintain the quality of
the liquid being delivered. Recommendations are given
for activities specific to polymer ultrapure water and
liquid chemical systems used in Semiconductor process
equipment.
NOTE 1: As with any SEMI guide, the practices outlined
herein are recommendations, not specifications. Users of this
document should recognize that alternate practices are not
excluded as long as they produce results that are equivalent to
those produced using the recommendations outlined here and
meet the requirements of the end user.
2 Scope
2.1 It is within the scope of this standard to recommend
procedures that complement the requirements in SEMI
F57 with the goal of ensuring the quality of the liquid
being delivered. Recommendations are provided in the
following areas:
• Manufacturing Facility
• Utilities
• System Design
• Pre-Production and Inspection
• Assembly
• System Testing
• Packaging
• Traceability
2.2 For the purposes of this document, systems include
all liquid delivery components inside semiconductor
process equipment and ancillary support equipment, as
well as additional plumbing provided by the OEM with
the processing equipment. This includes any assembly
of two or more liquid delivery components provided
with or within semiconductor process equipment.
2.3 Typical semiconductor process equipment with
ultrapure water and liquid chemical delivery systems
includes, but is not limited to the following:
• Wafer Handling Equip.
• Wafer Cleaning Systems
• Chemical Filtration/Mixing Skids provided by
OEM
• Wet Clean Stations
• Wafer Scrubbers
• CMP
• Photolithography coaters and developers
• Ion Implanters
• Metrology equipment
NOTICE: This standard does not purport to address
safety issues, if any, associated with its use. It is the
responsibility of the users of this standard to establish
appropriate safety and health practices and determine
the applicability of regulatory or other limitations prior
to use.
3 Limitations
3.1 This standard does not define the performance
requirements of components, which may be addressed
by SEMI F57. Nor does this standard define the
performance requirements of equipment systems.
Facility distribution systems are also outside the scope
of this standard.
3.2 Organic liquids, such as isopropyl alcohol and
methyl alcohol, are typically in contact with stainless
steel or other non-polymeric components. The polymer
systems described within this document are NOT
intended for use with such organic liquids. Refer to
SEMI E49.4, SEMI E49.5, and SEMI E49.6 for
information on stainless steel components.

SEMI E49.7-0304 © SEMI 1995, 2004 2
3.3 System design issues outside those that directly
impact liquid purity or quality are not within the scope
of this document’s recommendations and are left to the
individual system designers.
3.4 Polymer systems described within this document
are intended for use in ultrapure water and liquid
chemical delivery only. Their performance
requirements may exceed the needs of systems used in
drainage and other lesser quality liquids.
4 Referenced Standards
4.1 SEMI Standards
SEMI C3.28 Standard for Nitrogen (N2), VLSI
Grade in Cylinders, 99.9996% Quality
SEMI C41 Specifications and Guidelines for 2-
Propanol
SEMI E49 Guide for Standard Performance,
Practices, and Sub-Assembly for High Purity Piping
Systems and Final Assembly for Semiconductor
Manufacturing Equipment
SEMI E49.4 Guide for High Purity Solvent
Distribution Systems in Semiconductor Manufacturing
Equipment
SEMI E49.5 Guide for Ultrahigh Purity Solvent
Distribution Systems in Semiconductor Manufacturing
Equipment
SEMI E49.6 Guide for Subsystem Assembly and
Testing Procedures – Stainless Steel Systems
SEMI F34 Guide for Liquid Chemical Pipe Labeling
SEMI F57 Provisional Specification for Polymer
Components Used in Ultrapure Water and Liquid
Chemical Distribution Systems
SEMI F61 Guide for Ultrapure Water System Used
in Semiconductor Processing
4.2 Federal Standard (FED-STD)
1
Fed Stand 209E — Airborne Particulate Cleanliness
Classes in Cleanrooms and Clean Zones
1 Available from General Service Administration, Federal Supply
Service Bureau, Specification Section, Suite 8167, 470 East L' Enfant
Place SW, Washington, D.C. 20407.
4.3 ISO Document
2
ISO 14644 Cleanrooms and Associated Controlled
Environments – Part 1 Classification of Air Cleanliness
NOTICE: Unless otherwise indicated, all documents
cited shall be the latest published versions.
5 Terminology
5.1 See Section 4 of SEMI E49.
6 Manufacturing Facility Recommendations
6.1 Cleanroom Class designations as used within this
document are defined within Federal Standard 209E
Airborne Particulate Cleanliness Classes in Clean
rooms and Clean Zones. (ISO standard 14644-1
classifications are listed parenthetically.)
6.2 Materials Storage Area The storage area for
components and assemblies should be a dedicated
enclosed area, protected from the elements and
separated from other materials. Only components and
assemblies that have passed inspection, and are clean
and packaged should be placed in the storage area.
6.3 Gowning Area Gowning area should be Class
10,000 (ISO Class 7) or better. All personnel working
in cleanrooms should follow appropriate gowning
protocol such as: wear booties prior to entering the
gowning area; and wear gowns, hood, boots, gloves,
and safety glasses before entering clean areas.
6.4 Staging Area Staging Area should be Class
10,000 (ISO Class 7) or better. The staging area (if
used) should be located immediately outside the
assembly cleanroom, with appropriate access to the
assembly cleanroom.
6.5 Assembly Areas All production operations such
as cutting, welding, cleaning, assembly, final
integration, final test, and packaging (if applicable)
should be performed in a class 10,000 (ISO Class 7)
cleanroom or better.
7 Utility Recommendations
7.1 Nitrogen (Uses include leak testing of non-brittle
materials, drying, and purging.)
• Nitrogen quality should meet requirements of
SEMI C3.28.
• Particle filtration should be 99.99999% removal of
0.003 micron particles.
2 International Organization for Standardization, ISO Central
Secretariat, 1, rue de Varembé, Case postale 56, CH-1211 Geneva 20,
Switzerland. Telephone: 41.22.749.01.11; Fax: 41.22.733.34.30
Website: www.iso.ch

SEMI E49.7-0304 © SEMI 1995, 2004 3
NOTE 2: Use 316L electropolished tubing or PFA tubing for
purge piping. (Use tubing that does not degrade N
2
.)
7.2 Ultrapure Water (Uses include cleaning and
rinsing.)
• Resistivity ≥ 18 mega ohm-cm @ 25° C (77° F)
• TOC — < 20 ppb
• Silica — < 5 ppb
• Particles — < 1 particle/milliliter @ 0.1 µ m size
• Bacteria — < 10 colonies/100 milliliter
• Hot Ultrapure Water Temperature — 80° C
(176° F), minimum
NOTE 3: If testing requirements dictate, access to higher
quality ultrapure water may be appropriate in portions of the
facility. Additional information related to ultrapure water
facility design and terminology may be obtained in SEMI
F61.
7.3 2-Propanol/IPA (Uses include cleaning.)
• 2-Propanol/IPA quality should meet requirements
of SEMI C41, Grade 1
7.4 Clean Dry Air (CDA) or Oil Free Air (Uses include
pneumatic control and air actuation.)
7.4.1 CDA is not recommended for use on cleaned
wetted surfaces. Nitrogen is recommended for drying
cleaned wetted surfaces because the purity level is
clearly defined and controlled.
8 System Design Recommendations
8.1 General Recommendations — The intent of this
section is to recommend design practices that ensure the
quality of the liquid being delivered. These
recommendations should be considered along with
design constraints such as minimizing liquid
consumption, cost, ensuring maintainability, and
limiting complexity. In addition, the appropriateness
and simplicity of the facility interface should be
considered.
8.2 Component Recommendations — Components
should limit system exposure to ionic, metallic, total
organic carbon, and particle contamination.
8.2.1 All applicable components should comply with
SEMI F57.
8.2.2 For components not addressed in SEMI F57, a
discussion of recommended materials (similar to that
found in SEMI F57) may benefit the reader and is
therefore provided.
8.2.2.1 Care should be taken to ensure that the
materials are compatible with the liquid streams for
long term applications. Additionally, it is important
that the materials used be compatible with the
application temperature and/or sanitization methods
such as ozone, UV light and/or hydrogen peroxide.
8.2.2.2 These recommendations often imply the use of
existing materials of choice, such as high purity grades
of perfluoroalkoxy (PFA), polytetrafluoroethylene
(PTFE), and polyvinylidene fluoride (PVDF).
However, unique design specifications or new materials
may result in instances where significant efficiencies
may be achieved while maintaining substantially
equivalent performance. These scenarios could result
in the use of new or existing materials such as
ethylenechlorotrifluoroethylene (ECTFE), polyether-
etherketone (PEEK), polypropylene (PP), acetal resin
(such as Delrin®™
3
, Celcon®™
1
and others),
polyvinyl chloride (PVC), perfluoromethylether-based
perfluoroalkoxy (MFA), etc.
8.2.2.3 Due to purity and traceability issues,
reprocessed or regrind material is not recommended.
8.3 Joining Recommendations — Joining technology
that is free of dead space and entrapment areas is
recommended to reduce negative effects such as
microbial proliferation and impacts to slurry particle
size distribution. For this reason pipe thread
connections are not recommended.
8.3.1 Tubing should be joined with flare fittings, or
similar dead space free technology. Preparation and
joining of fittings should be performed in accordance
with component manufacturer recommendations.
8.3.1.1 Care should be taken to ensure that dissimilar
flare fittings are not joined together. When possible,
one style of fitting should be used throughout the
system. Manufacturers should be consulted prior to
using similar style fittings from different manufacturers
interchangeably.
8.3.2 Pipe should be joined with welds that minimize
dead space and entrapment areas. Preparation and
welding should be performed in accordance with
component manufacturer’s recommendations.
NOTE 4: Users of this guideline are cautioned that suitable
welding methods, such as thermal butt welding, may be
covered by patents or other intellectual property.
8.3.2.1 Glue, solvent, or thermal socket welding of
pipe is not recommended.
8.4 System Volume Recommendations — When
possible, dead volumes should be eliminated and
overall system volume should be minimized to reduce
negative effects on purity as well as flush times.