semi合集-English.pdf - 第3762页

SEMI F5-1101 © SEMI 1990 , 2001 6 form su b-micron solid aeros ols of ammon ium chloride, ammo niu m fluo ride , a mmoni um nitr ate, or a mmoni um sulfate, respectively. 8.1.5.10 A ny exha usts ca rr ying a mmo nia shou…

100%1 / 7923
SEMI F5-1101 © SEMI 1990, 20015
8 End-of-Pipe Abatement Technologies
8.1 Group 1 Acid Abatement
8.1.1 The appropriate abatement technology for this
category is commonly called " wet scrubbing."
8.1.2 Many, if not all, of the semiconductor processes
have traditionally been exhausted through centralized
wet scrubbers.
8.1.2.1 This procedure has limited technical
acceptability and may not meet the requirements of all
regulatory agencies.
8.1.2.2 This technology should be targeted at
abatement of acid gases, vapors, mists, and fumes
emitted from CVD, dry etching, and wet chemical
operations.
8.1.2.3 Most wet chemical processes are typically
carried out under local exhaust ventilation devices, such
as fume hoods, or in specially designed rooms that are
totally exhausted. These types of operations include:
Processes used to clean wafers or clean wafer
handling equipment (such as quartz components,
tubing),
Processes used in wafer fabrication for surface
treatment such as oxide, silicon nitride and other
surface treatments, (e.g., metal etching), and
Processes used for development of positive
photoresist.
8.1.2.4 The chemical species emitted depends on both
the chemicals used in the processes and the conditions
of use.
8.1.2.5 Volatile acids (e.g., hydrochloric (HCl),
hydrofluoric, nitric, and acetic) yield corresponding
gases and vapors, especially when heated.
8.1.2.5.1 The reaction of hydrochloric and nitric acids
in aqua regia yields nitrosyl chloride (NOCl) vapor and
elemental chlorine (Cl
2
) gas.
8.1.2.5.2 When sulfuric acid is heated, it yields both
sulfuric acid vapor (H
2
SO
4
) and sulfur trioxide (SO
3
).
8.1.2.5.3 Phosphoric acid (H
3
PO
4
) is not significantly
volatile, but spray may be carried over into the exhaust
system by mechanical entrainment.
8.1.2.5.4 Under appropriate conditions, spray droplets
of any of the chemicals used may be mechanically
entrained into the ventilation air exhausted from the
various processes.
8.1.3 Design and selection of scrubbing equipment for
the acid exhaust systems must take into account both
the chemical and physical properties of the materials
being emitted.
8.1.4 The principles involved in collection of
particulate matter (including liquid aerosols) are
entirely different from those determining absorption of
gases.
8.1.5 Current Practice
8.1.5.1 Exhausts carrying acid compounds comprise
the largest volume of air discharged from a typical
semiconductor manufacturing plant.
8.1.5.2 The current practice is to connect most or all of
the corrosive sources to a central building exhaust
system and to discharge the combined gas streams to
one or more large wet scrubbers.
8.1.5.2.1 A variety of scrubber types might be used,
but the two main types are cross-flow and counter-
current scrubbers equipped with packing material of
some type.
8.1.5.3 The scrubbers usually are fed with a stream of
water (potable, recycled, etc.).
8.1.5.4 A side stream of water is bled from the
scrubber to a wastewater line.
8.1.5.5 It is futile to discharge organic solvents to
water scrubbers even if the organic solvents are, to
some degree, soluble in water.
8.1.5.5.1 Any dissolved organic solvent will eventually
be desorbed from the water and will escape to the
atmosphere, or be discharged as wastewater.
Additionally, these organics could serve to propagate
biological growth in the scrubber.
8.1.5.6 Exhausts from process tools are frequently
discharged to the appropriate building exhaust systems,
either with or without point-of-use abatement.
8.1.5.7 Arsine and phosphine, which have only slight
solubility in water, pass through the water scrubbers so
that the effect of discharging these gases into the
building scrubber system is limited to dilution.
Fluorine and chlorine also have limited solubility in
water and may pass through water scrubbers without
sufficient abatement. POU abatement devices should
be considered for these types of gases.
8.1.5.8 Preliminary oxidation of these and numerous
other process gases results in formation of fine fumes
and other aerosols that will be collected with only low
efficiencies by the typical large, low-energy wet
scrubbers.
8.1.5.9 If ammonia is discharged into a system that
also carries hydrogen chloride, hydrogen fluoride, nitric
acid, or sulfuric acid; it will react, in the vapor phase, to
SEMI F5-1101 © SEMI 1990, 2001 6
form sub-micron solid aerosols of ammonium chloride,
ammonium fluoride, ammonium nitrate, or ammonium
sulfate, respectively.
8.1.5.10 Any exhausts carrying ammonia should be
discharged to a separate scrubber or a point-of-use
ammonia abatement used at the process discharge.
8.1.6 Chemistry of Pollutants
8.1.6.1 Effective abatement of any compound requires
careful consideration of the chemistries and physical
states of the specific compounds being abated.
8.1.6.2 The packed-bed scrubbers commonly employed
should generally be adequate for absorption of readily
soluble gases, if appropriate operating conditions are
also maintained.
8.1.6.3 Misuse can negate the potential performance of
the scrubbers.
8.1.6.4 As scrubbers are low-energy devices (pressure
drops on the order of 2.5 to 10 cm (1-4 inches) of water,
they are incapable of effectively collecting fine aerosols
such as the ammonium salts mentioned above.
8.1.6.5 The most economic design approach, therefore,
is to arrange the exhaust system and use POU
abatement devices to avoid formation of such aerosols,
where possible.
8.1.6.6 The practice of using only recirculated water in
the scrubber, to absorb acid vapors and to neutralize the
water bleed stream should be reviewed to ensure that
scrubber efficiency is not affected.
8.1.6.7 Acid gases, such as hydrogen chloride and
hydrogen fluoride, are readily soluble in water. The
partial pressure of acid gases in equilibrium with the
solution, which increases with increasing solute
concentration, reduces the absorption of additional gas.
Reduction in absorption can be minimized by
increasing the rate of water blow-down (i.e., using more
fresh water make-up).
8.1.6.8 However, increasing the rate proportionately
increases the consumption of water and the volume of
water that must be treated before discharge as
wastewater.
8.1.6.9 The introduction of an alkaline solution (e.g.,
sodium hydroxide) in the scrubber can assist in
removing compounds from the gas stream if the use of
water alone does not provide adequate removal
efficiencies. The use of additives in the scrubber can, in
itself, create safety and environmental concerns.
8.1.6.10 Some of the neutralized absorbent must be
bled off from the recirculated stream to prevent the
brine concentration from reaching an excessively high
level, but water consumption and the volume of waste
can still be reduced by alkaline solution.
8.1.6.11 Aqua regia is a reactive mixture of nitric and
hydrochloric acids. The reaction produces nitrosyl
chloride and elemental chlorine:
HNO
3
+ 3HCl è NOCl + Cl
2
+ 2H
2
O
8.1.6.12 The nitrosyl chloride vapor is readily
decomposed by absorption in an alkaline solution:
NOCl + 2NaOH è NaNO
2
+ NaCl + H
2
O
8.1.6.13 Elemental chlorine has only a limited
solubility in water, and an alkaline solution (pH > 10)
must be used to attain adequate absorption efficiencies:
Cl
2
+ 2NaOH è NaOCl + NaCl + H
2
O
8.1.6.14 During the initial reaction of the nitric and
hydrochloric acids, hydrogen chloride gas and nitric
acid vapors are volatilized along with the nitrosyl
chloride and chlorine.
8.1.6.15 Nitrogen dioxide may also be produced by
decomposition of nitric acid.
8.1.6.16 All these compounds can be absorbed, to
some degree, in an alkaline solution.
8.1.6.17 If a pollutant is in a particulate form (solid or
liquid), its collection is only slightly affected by its
chemical nature or solubility.
8.1.6.18 The dominant factor determining particulate
collectability is particle size.
8.1.6.19 Abatement of particulate compounds requires
a high-energy method (usually creating an extremely
high pressure-drop across the abatement device) which
can be costly in both energy and abatement device size
requirements.
8.1.7 Scrubber Design and Selection
8.1.7.1 A variety of commercially available scrubbers
are applicable to absorption of readily soluble gases.
8.1.7.2 These include packed-bed counter-current, co-
current, and horizontal cross-flow scrubbers, horizontal
spray chambers, vertical spray towers, and gas-
atomizing scrubbers such as the venturi scrubber.
8.1.7.3 To some extent, the choice of scrubber type is a
matter of preference, as it is usually possible to obtain
equivalent performance on the soluble gases with
different types of devices; however, more packing or
higher liquid loading may be required on some devices.
8.1.8 The choice is likely to be limited by a
consideration of practical or economic factors such as
cost, available space, and weight (e.g., it is possible to
SEMI F5-1101 © SEMI 1990, 20017
reduce the size of the scrubber, usually at the cost of
increased energy consumption).
NOTE 5: See Appendix 1 for absorber design criteria.
8.2 Group 2Acid Aerosols
8.2.1 Part of acid emissions may be in the form of
mists (fine droplets or aerosols) rather than gases.
These may be composed of relatively non-volatile acids
such as phosphoric and sulfuric acids.
8.2.1.1 The mechanisms of removal of particulate
matter (including liquid aerosols) from gas streams are
entirely different from those involved in the absorption
of gases (See Sections 13.1 through 13.3).
8.2.1.2 The critical factor in the collection process is
the particle size of the mist. If the mist is relatively
coarse, as apparently is the case in most instances, the
same types of scrubbers that are used for gas absorption
should collect the mists with adequate efficiency.
8.2.1.3 If a mist having a particle size in the
micrometer or sub-micrometer range is encountered, it
will be necessary to use a high-energy scrubber or a
scrubber with a high-pressure-drop, sub-micron filter to
obtain adequate collection efficiency.
8.2.1.4 Whenever such a fine mist or other aerosol is
encountered, the gas stream from the source should be
abated at point-of-use or separately from the other
exhaust gas streams in the plant so as to minimize
energy costs.
8.2.1.5 Abatement systems utilizing a scrubber with a
high-pressure-drop, sub-micron filter are being used in
the semiconductor industry to reduce emissions from
aqua-regia processes, hot nitric baths and spray etchers
using nitric acid (entrained in exhaust).
8.2.2 It has been determined experimentally that the
collection efficiency of a scrubber on a given mist or
dust is a function of the energy consumed in the
exposure of the particle to the liquid in the scrubbing
process.
8.2.2.1 The relationship between energy consumption
and efficiency is little affected by the geometry or size
of the scrubber or by the method by which the energy is
applied to making contact between the gas and the
liquid (See Sections 13.1 through 13.3).
8.2.2.2 The energy consumption required to attain a
given efficiency increases with a decrease in the size of
the aerosol (e.g., mist or dust). In most of the scrubbers
used in the semiconductor industry, the energy
consumed is drawn from the gas stream in the form of
pressure drop.
8.2.3 The energy/efficiency relationship provides a
convenient and practical method for particle and
aerosol scrubber design. It is essentially independent of
the size of the scrubber, at least down to a very small
size (perhaps 150 to 300 L/min (5–10 ft
3
/min) capacity,
and possibly even smaller). Hence, a small pilot unit
can be used to determine performance on an actual
plant exhaust stream.
8.2.3.1 Tests can also be made under laboratory
conditions, using synthetic aerosols generated for the
purpose.
8.2.3.2 The major problem in using synthetic aerosols
is in replicating the aerosols actually encountered in
practice.
8.2.3.3 The pilot plant scrubber should be tested over a
range of pressure drops to give a well-defined pressure
drop/efficiency correlation.
8.3 Group 3Ammonia
8.3.1 Ammonia gas (NH
3
) can be either a process gas
or evolved from ammonium hydroxide used in wet
chemical cleaning of wafers. As previously discussed,
ammonia (NH
3
) exhausted through the acid system will
react with the acids present producing an ammonium
salt aerosol that is not easily abated.
8.3.1.1 Packed-bed scrubbers are not very efficient at
removing sub-micron ammonium halide aerosols, even
though they are water-soluble.
8.3.2 Wet scrubber technologies, as listed above, are
suitable for removal of ammonia provided they are
operated and maintained at low pH (e.g., 3–5).
8.3.2.1 This is normally achieved by the use of sulfuric
acid dosing.
8.3.3 Processes that emit both ammonia and acid gases
(such as nitride deposition) should be fitted with a
point-of-use ammonia scrubber, prior to being
exhausted to the acid exhaust.
8.4 Group 4Volatile Organic Compounds (VOCs)
8.4.1 VOCs can represent a large proportion of
exhausted air streams within typical semiconductor
operations. The pollutants are produced from processes
such as solvent cleaning, and photoresist application
and stripping. Such processes typically contribute
flammable, hazardous, and/or environmentally harmful
compounds (e.g., VOCs, which participate in ozone
formation in the atmosphere) to the exhausted air
stream.
8.4.2 There are three primary abatement technologies
used at end of pipe for this category: adsorption,
recovery and oxidation. Adsorption generally uses
hydrophobic zeolite or activated carbon. The oxidation
process usually is thermal or may be catalytic.