semi合集-English.pdf - 第1977页
SEMI E54.4-0704 © SEMI 1997, 2004 12 DeviceNet Statement of Compliance Message Router Object 0x02 Object Class ID Description Get Set Value Limits Attributes Open 1 Revision ❑ ❑ ___________________ 4 Optional attribute l…

SEMI E54.4-0704 © SEMI 1997, 2004 11
DeviceNet Statement of Compliance
Identity Object 0x01
Object Class ID Description Get Set Value Limits
DeviceNet
Required
Object
Implementation
Attributes Open 1 Revision ❑ ❑ ___________________
2 Max instance ❑ ❑ ___________________
❑ None Supported 6 Max ID of class attributes ❑ ❑ ___________________
7 Max ID of instance
attributes
❑ ❑ ___________________
DeviceNet Services Parameter Options
Services ❑ Get_Attribute_All ____________________________
❑ Reset ____________________________
❑ None Supported ❑ Get_Attribute_Single ____________________________
❑ Find_Next_Object_Instance ____________________________
Object Instance ID Description Get Set Value Limits
Attributes Open 1 Vendor ❑ ❑ ___________________
2 Product type ❑ ❑ ___________________
❑ None Supported 3 Product code ❑ ❑ ___________________
4 Revision ❑ ❑ ___________________
5 Status ❑ ❑ ___________________
6 Serial number ❑ ❑ ___________________
7 Product name ❑ ❑ ___________________
___________________
8 State ❑ ❑ ___________________
DeviceNet Services Parameter Options
Services ❑ Reset ___________________________
❑ Get_Attribute_All ___________________________
❑ None Supported
Vendor-Specific Additions If yes, fill out the Vendor-Specific Yes ❑
Additions form on page F_7. No ❑
X Get to indicate that attribute value is returned by the use of Get_Attribute_Single service.
X Set to indicate that attribute value is written to by the use of Set_Attribute_Single service.
F_ 2

SEMI E54.4-0704 © SEMI 1997, 2004 12
DeviceNet Statement of Compliance
Message Router Object 0x02
Object Class ID Description Get Set Value Limits
Attributes Open 1 Revision ❑ ❑ ___________________
4 Optional attribute list ❑ ❑ ___________________
DeviceNet
Required
Object
Implementation
❑ None Supported 5 Optional service list ❑ ❑ ___________________
6 Max ID of class attributes ❑ ❑ ___________________
7 Max ID of instance
attributes
❑ ❑ ___________________
DeviceNet Services Parameter Options
Services ❑ Get_Attribute_all ____________________________
❑ Get_Attribute_Single ____________________________
❑ None Supported
Object Instance ID Description Get Set Value Limits
Attributes Open 1 Object list ❑ ❑ ___________________
2 Maximum connections
supported
❑ ❑ ___________________
❑ None Supported
3 Number of active
connections
❑ ❑ ___________________
4 Active connections list ❑ ❑ ___________________
DeviceNet Services Parameter Options
Services ❑ Get_Attribute_All ____________________________
❑ Get_Attribute_Single ____________________________
❑ None Supported
Vendor-Specific Additions If yes, fill out the Vendor-Specific Yes ❑
Additions form on page F_7. No ❑
X Get to indicate that attribute value is returned by the use of Get_Attribute_Single service.
X Set to indicate that attribute value is written to by the use of Set_Attribute_Single service.
F_ 3

SEMI E54.4-0704 © SEMI 1997, 2004 13
DeviceNet Statement of Compliance
DeviceNet Object 0x03
Object Class ID Description Get Set Value Limits
Attributes Open 1 Revision ❑ ❑ ___________________
❑ None Supported
DeviceNet Services Parameter Options
Services ❑ Get_Attribute_Single ____________________________
❑ None Supported
Object Instance ID Description Get Set Value Limits
Attributes Open 1 MAC ID ❑ ❑ ___________________
2 Baud rate ❑ ❑ ___________________
❑ None Supported 3 BOI ❑ ❑ ___________________
4 Bus-off counter ❑ ❑ ___________________
5 Allocation information ❑ ❑ ___________________
6 MAC ID switch changed ❑ ❑ ___________________
7 Baud rate switch changed ❑ ❑ ___________________
8 MAC ID switch value ❑ ❑ ___________________
9 Baud rate switch value ❑ ❑ ___________________
DeviceNet Services Parameter Options
Services ❑ Get_Attribute_Single ____________________________
❑ Set_Attribute_Single ____________________________
❑ None Supported ❑ Allocate M/S connection set ____________________________
❑ Release M/S connection set ____________________________
Vendor-Specific Additions If yes, fill out Vendor-Specific Yes ❑
DeviceNet
Required
Object
Implementation
Additions form on page F_7. No ❑
X Get to indicate that attribute value is returned by the use of Get_Attribute_Single service.
X Set to indicate that attribute value is written to by the use of Set_Attribute_Single service.
F_ 4