100%1 / 7923
SEMI D31-1102 © SEMI 2002 3
RELATED INFORMATION 1
EXPERIMENT OUTLINE FOR CALCULATION OF MEASUREMENT
INDEX FOR LUMINANCE MURA IN FPD IMAGE QUALITY INSPECTION
NOTE: This related information is not an official part of SEMI D31. This related information was approved for
publication by full letter ballot procedures on July 19, 2002.
R1-1 Purpose
R1-1.1 It has been reported that under the range of
certain conditions, a basic expression of FPD mura
quality level can be made, using their size and
contrast
[1]
. Here, recreating those experiments, we
verified their reproducibility, conducting the
experiment with a goal of calculating a measurement
index for luminance mura for standardization.
R1-2 Experiment Method
R1-2.1 Experiment Equipment
R1-2.1.1 The experiment utilized a 14.1 inch, 1024 X
768 pixel backlit TFT/LCD. As there was a need to
display low contrast luminance muras, it was reworked
to display 256 gradations in a 43 cd/m
2
~ 54 cd/m
2
range. A program capable of displaying rectangular
and round muras as desired was created, and the muras
were displayed in the center of the prepared LCD. The
subjects could freely adjust the luminance of the
displayed luminance muras using a handheld ten-key
pad.
R1-2.2 Experiment Conditions
R1-2.2.1 21 types of muras were used. These were
four round types (diameter:7, 25, 55, 305 pixels) and 17
rectangular types (31×1, 153×1, 240×1, 480×1, 31×2,
153×2, 240×2, 31×3, 153×3, 240×3, 31×16, 69×35,
140×17, 240×10, 1×31, 1×153, 1×240). Observation
conditions were a viewing distance of 500 mm, and
view angle normal to the center of the LCD. The
experiment room was a darkroom, and the background
luminance of the luminance mura was 48 cd/m
2
.
R1-2.3 Subjects/Experiment Procedure
R1-2.3.1 The subjects for the experiment were 16
adults, with no eye disease and with near vision
strength (50 cm) of 1.2 or greater for both eyes. Of the
16 subjects, there was an Expert group of 8 (7 male, 1
female, average age 40 years), consisting of engineers
from LCD makers, who regularly conduct mura
inspections and analysis. The remaining 8 subjects (6
males, 2 females, average age 21) were college
students, a Novice group who were conducting
luminance mura evaluation for the first time. Using the
ten-key pad, the subjects adjusted the luminance of
mura, to a point “where mura can just no longer be
detected” (referred to as “jnd”: just noticeable
difference below) and to a “point where mura can
clearly be detected” (referred to as “distinct” below),
recording the contrasts at these times. Muras brighter
than the background and lighter than the background
were both targeted.
R1-3 Experiment Results
R1-3.1 The following matters became clear from the
experiment.
• The larger the area of the mura, the smaller jnd
contrast (C jnd) became. (Muras are more visible
as area becomes larger)
• Muras with a width of one pixel, compared to other
muras, require nearly 1.5 to 2 times the contrast.
(Muras with a width of one pixel are difficult to
detect)
• Comparing the distribution between the subjects,
there was no difference between the Expert and
Novice groups for jnd contrast (C jnd)
• Compared to the Expert group, the Novice group
had a larger distribution for distinct contrast.
R1-3.2 The relation between mura area and jnd
contrast showed the same trend as in past experience
[1]
,
and the quality of reproducibility was confirmed.
Therefore at this point, for the sake of standardization,
we examined the function for mura area, and tried
linear regression for it with jnd contrast. Figure 1
shows the results. When the horizontal axis is
33.0
1
S
(S is mura area in mm
2
units), and the vertical axis is at
contrast, the bold line shows a strong correlation
coefficient, understood through linear regression.
R1-3.3 This bold line shows the relation between mura
area and contrast at the point where the mura becomes
just not detectable (jnd), and if area is determined, then
jnd contrast (C jnd) can be figured out. In Figure 1, ○
is a mura with a width of one pixel, and ● represents
other muras (not one pixel wide) respectively
representing the averages of the 16 subjects. As noted
above in 2), a mura with a width of one pixel tends to
be slightly different, which is why they were handled
separately. Also considering past experiment results,
when viewing distance is 500mm, the 0.3mm level
SEMI D31-1102 © SEMI 2002 4
seems to be the boundary. Here we propose Equation 1
which regressively analyzes the ● in Figure 1 as
criteria for standardization.
72.0
1
97.1
33.0
+
=
S
Cjnd
….. Equation 1
R1-3.4 The criteria for standardization, jnd, is
determined by the C jnd straight line, but we also
propose, based on this criteria, quality levels for other
visible muras. Figure 1 shows straight lines made up of
2.0 jnd and 3.0 jnd. × is distinct contrast for the
Expert group, but in cases besides 1-pixel wide muras,
it can be understood to be distributed slightly above the
2.0 jnd straight line.
R1-3.5 This indicates that the straight-line relationship
of Figure 1 is not only jnd level, but also consists of
visible contrast level. Accordingly, with the bold line
jnd as a standard, mura quality level can be expressed
by n in n x jnd. From the experiment results this time,
from 3.0 being a level slightly above distinct, it can be
thought that it is desirable to operate using a range of
levels 1.0 to 3.0.
R1-4 Summary
R1-4.1 A proposal was made regarding the
quantization of FPD luminance mura. The quality level
of a mura can be expressed as a function between mura
area and contrast, using the contrast at the jnd point as
criteria. By using this method, even if mura area,
shape, or contrast is different, we can now calculate
similar quality level jnd.
C jnd = 1.97 (1/f(S) ) + 0.72
R
2
= 0.87
0
1
2
3
4
5
6
7
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
1/f(S)
Contrast (%)
3.0 jnd
2.0 jnd
1 pixel-width Mura
f(S) = S
0.33
S :unit (mm
2
)
Figure R1-1
Relation between luminance mura area and jnd contrast (C jnd)
(●: jnd contrast of mura not 1 pixel wide, ○:jnd contrast of mura 1 pixel wide,
×: Distinct contrast of all muras (Average of Expert group only))
Prepared by R. Yoshitake and T. Tamura
SEMI D31-1102 © SEMI 2002 5
NOTICE: SEMI makes no warranties or representations as to the suitability of the standards set forth herein for any
particular application. The determination of the suitability of the standard is solely the responsibility of the user.
Users are cautioned to refer to manufacturer' s instructions, product labels, product data sheets, and other relevant
literature, respecting any materials or equipment mentioned herein. These standards are subject to change without
notice.
By publication of this standard, Semiconductor Equipment and Materials International (SEMI) takes no position
respecting the validity of any patent rights or copyrights asserted in connection with any items mentioned in this
standard. Users of this standard are expressly advised that determination of any such patent rights or copyrights, and
the risk of infringement of such rights are entirely their own responsibility.
Copyright by SEMI® (Semiconductor Equipment and Materials
International), 3081 Zanker Road, San Jose, CA 95134. Reproduction o
the contents in whole or in part is forbidden without express written
consent of SEMI.