semi合集-English.pdf - 第6147页

SEMI G31-0997 © SE MI 1986, 1997 1 SEMI G31-0997 TEST METHOD FOR DETERMINING THE ABRASIVE CHARACTERISTI CS OF MOLDING COMP OUNDS 1 Purpose This docum ent describes the m e thod to m ea sure th e abrasive ch aracteristics…

100%1 / 7923
SEMI G30-88 © SEMI 1986, 1988 6
Figure 5
Mounting Surface Temperature Measurements
NOTICE: These standards do not purport to address
safety issues, if any, associated with their use. It is the
responsibility of the user of these standards to establish
appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
SEMI makes no warranties or representations as to the
suitability of the standards set forth herein for any
particular application. The determination of the
suitability of the standard is solely the responsibility of
the user. Users are cautioned to refer to manufacturer’s
instructions, product labels, product data sheets, and
other relevant literature respecting any materials
mentioned herein. These standards are subject to
change without notice.
The user’s attention is called to the possibility that
compliance with this standard may require use of
copyrighted material or of an invention covered by
patent rights. By publication of this standard, SEMI
takes no position respecting the validity of any patent
rights or copyrights asserted in connection with any
item mentioned in this standard. Users of this standard
are expressly advised that determination of any such
patent rights or copyrights, and the risk of infringement
of such rights, are entirely their own responsibility.
Copyright by SEMI® (Semiconductor Equipment and Materials
International), 3081 Zanker Road, San Jose, CA 95134. Reproduction o
f
the contents in whole or in part is forbidden without express written
consent of SEMI.
SEMI G31-0997 © SEMI 1986, 19971
SEMI G31-0997
TEST METHOD FOR DETERMINING THE ABRASIVE
CHARACTERISTICS OF MOLDING COMPOUNDS
1 Purpose
This document describes the method to measure the
abrasive characteristics of molding compounds by
measuring mold orifice weight loss as a function of
molded volume.
2 Scope
2.1 All thermoset molding compounds used for
microelectronic device encapsulation contain filler
materials, typically 60–90% — which contribute to
mold wear. Mold wear, typically at gates, is a major
reason for mold rework. This test method may be used
by suppliers to evaluate new molding materials or
control current materials or by customers to evaluate
the use of new materials. This test method provides a
comparison of abrasiveness between materials.
2.2 This procedure can be used to determine the
abrasive character of a given molding compound.
Knowing the conditions of test, the results of the test,
and the mold life experience (within one’s own
company) in the field, it is possible to judge if a
molding compound is more or less abrasive to current
compound in use.
3 Referenced Documents
3.1 Operational manuals for all equipment listed
within this document.
3.2 Mold compound data sheets
4 Method
This procedure determines the abrasive character of a
given filled molding compound by measuring orifice
weight loss as a function of extruded volume.
5 Interferences
5.1 Care must be taken to avoid orifice weight loss by
mishandling during placing and removing the orifice
from the mold base.
5.2 Before the orifice is re-weighed after molding,
carefully remove all contamination.
6 Equipment
6.1 Transfer molding press, 50 tons clamp minimum
6.2 Dielectric preheater
6.3 Orifice insert and mold assembly (See Figures 2–
6.)
6.4 Mold base with pot diameter 1.75 to 2.00 inches
6.5 Photoelectric safety light screen
6.6 Stop watch
6.7 Pyrometer
6.8 Force gauge
6.9 Asbestos gloves
7 Procedure
7.1 Equipment Set-Up — Orifice Mold Installation
(see Figure 1).
7.1.1 Place mold assembly on mold base and align
orifice retainer opening with center of transfer pot.
7.1.2 Clamp bottom plate of mold assembly to bottom
mold platen.
7.1.3 Set press limit switch to ensure clamp slow close
is initiated 1" from completion of mold closing.
7.2 Process Parameters
7.2.1 Set up the molding parameters according to the
material data sheet recommendations or expected use
conditions, if known. These conditions include:
Mold temperature
Pre-heat temperature or pre-heat time
Transfer speed
Transfer pressure
Clamp pressure
Cure time
NOTE: The charge weight to be determined by trial molding
shots to achieve a cull thickness between 0.060–0.120" and a
suitable weight of extrudate.
7.3 Operating Procedure
7.3.1 Weigh orifice to one ten-thousandth of a gram.
Record weight.
7.3.2 Verify process parameter settings.
7.3.3 Place orifice in orifice retainer and clamp mold
assembly.
SEMI G31-0997 © SEMI 1986, 1997 2
7.3.4 Preheat preformed material to the required
temperature.
7.3.5 Insert preheated material into transfer pot and
activate transfer ram (semi-automatic mode).
7.3.6 Start stopwatch when extrudate first appears.
Record total extrusion time.
7.3.7 Collect and weigh extrudate to nearest one tenth
of a gram. Record extrudate weight.
7.3.8 At the end of cure cycle, remo ve orifice from
retainer. Loosen set-screws to split orifice and, with
compressed air, blow out cured slug.
7.3.9 Ensure mating orifice halves are clean, realign
the halves and tighten set screws.
7.3.10 Place orifice in retainer and repeat steps 7.3.4
through 7.3.9.
7.3.11 Repeat steps 7.3.4 through 7.3.10 until a
minimum of 40 shots are run.
7.3.12 Record the following:
1. Original orifice weight
2. Shot number
3. Extruded weight per shot in grams
4. Cumulative extruded weight in grams
5. Orifice weight in grams
6. Orifice percent weight loss
7. Extrusion rate
8 Calculation
8.1 Orifice Weight Loss
I
O
I
N
I
O
100%()= % wt. loss
I
O
= Initial orifice weight to ten thousandth of a gram
I
N
= Orifice weight after “N” number of shots to ten
thousandth of a gram
8.2 Plot on linear graph paper the orifice weight loss
vs. cumulative extruded weight.
8.3 Convert cumulative weight extruded to cumulative
volume extruded.
Example: Molding compound density 2.0 g/cm
3
cumulative weight = 2000 g
2000
2.0g
1000
3
3
g
cm
cm
×=
8.4 Convert cumulative volume extruded to equivalent
production mold shots.
Example: 28 mm × 28 mm × 3.4 mm - 208 Id PQFP
Package Volume:
28
1000
2 6656
3
mm × 28 mm × 3.4 mmx
cm
m
m
cm
3
3
=
.
Volume to shots:
1000 cm ×
sho
t
2.6656 cm
375 shots
3
3
=
8.5 Plot on linear graph paper the orifice weight loss
vs. equivalent production mold shots.