semi合集-English.pdf - 第982页

SEMI E129-1103 © SEMI 2003 20 R2-6 Neutralizing Charge on Insulators R2-6.1 Static charge on a conductive or sta tic- dissipative object can be co ntrolled if the obj ect is provided with a path for the charge to flow to…

100%1 / 7923
SEMI E129-1103 © SEMI 2003 19
ESD STM7.1 can be used to measure the resistance
to a groundable point and resistance point-to-point
for flooring,
ANSI ESD STM12.1 can be used to measure the
resistance to a groundable point for components of
chairs.
Resistance characteristics of the wrist straps used
to ground personnel are covered in ANSI ESD
S1.1.
Cleanroom garments may be tested with the
methods of ANSI ESD STM2.1.
R2-4 Static Charge Decay Time
R2-4.1 In some cases, it will be important to know the
actual time it takes to remove a known amount of
charge from an object.
FED-STD-101 Method 4046 is often used for
homogeneous materials.
ANSI ESD STM4.2 is used to measure decay time
of worksurface materials.
R2-4.2 Please be aware that static decay time may not
fully characterize an item or a material. However, the
information gathered in a decay time test may provide
valuable insight into the electrostatic performance of an
item or material when used in conjunction with other
data such as resistance or resistivity. Decay time is
only useful for materials with a high
resistance/resistivity. For materials with resistance less
than 10
10
, decay time does not apply because the
equipment used is unable to measure decay times faster
than 0.01 s.
R2-5 Measuring Static Charge Levels on
Personnel
R2-5.1 Since personnel are mobile electrical
conductors, they pose a significant hazard in any ESD-
susceptible workplace. Thus, grounding of personnel is
among the most important of all static control technical
requirements. All of the industry program management
standards accepted around the world require grounding
of personnel as a foremost requirement. The most
important consideration for personnel in a properly
designed electrostatic protective area (EPA) is to
maintain the resistance to ground at < 35 M for
operations handling parts sensitive to above 100-V
Human Body Model sensitivity. For areas handling
parts susceptible to less than 100-V HBM, the
resistance-to-ground specification should be reduced to
less than 10 M to ground. Testing by the ESD
Association has shown that at 35 M to ground, a
person can generate up to 100 V by vigorous movement
such as sliding feet on the floor. At 10 M to ground,
the maximum voltage potential drops to about 6 V, a
level that is highly unlikely to contribute to damaging
even the most sensitive parts (consider the resistance
discussion above). Standard wrist strap test methods
are described and defined in ANSI ESD S1.1.
R2-5.2 For high-risk applications, advanced testing of
personnel grounding systems may be required. A
modern concept for continuous verification of
personnel grounding includes wrist strap constant
monitor systems. Choosing an appropriate system of
constant monitoring requires an understanding of the
actual performance measurement. To verify personnel
grounding, it is important to measure the condition of
the total system including the interaction of all the
contact resistances, together with wrist strap bands and
skin as well as ground cord, and shoes or shoe straps
with skin or stocking moisture. Make sure all
measurements include all the resistive interconnections
of the grounding systems. Do not do system
measurements without including all the components
and personnel.
R2-5.3 A common grounding appliance for personnel
is a wrist strap and connecting ground cord attached to
a common point grounding terminal at a workstation.
Since this methodology is most suitable for seated
personnel, it is a stated requirement in all of the
recognized static control programs (i.e., ANSI ESD
S20.20, JEDEC JESD625, IEC 61340-5-1, and EN
61340-5-1 (formerly CENNELEC 100015-1).
R2-5.4 Another common methodology for grounding
mobile personnel is a static control floor with static
control footwear. If this concept is used as the primary
grounding system, the resistance to ground has to be the
same as for a wrist strap. A useful test method for
resistance to ground of personnel through a floor-
footwear system is ANSI ESD STM97.1. An
alternative methodology in ANSI ESD S20.20 where
the resistance to ground of the floor-footwear system is
above 35 M is to measure the voltage of a person
relative to ground using ESD STM97.2. This method
measures the charge generation characteristics of a
person moving about on a floor.
R2-5.5 Clothing coverings using approved static
control materials are often a requirement, especially in
cleanrooms. When ESD issues are involved, garments
need to be tested using approved test methods. A
useful method is ANSI ESD STM2.1.
R2-5.6 Additional static control information, useful
where personnel are concerned, may come from ESD
TR03 for gloves and finger cots, ESD TR05 for
garments, and ESD TR06 for triboelectrically charged
garments.
SEMI E129-1103 © SEMI 2003 20
R2-6 Neutralizing Charge on Insulators
R2-6.1 Static charge on a conductive or static-
dissipative object can be controlled if the object is
provided with a path for the charge to flow to earth
ground. Unfortunately, grounding methods do not
provide complete protection from static-related
problems. Even when earth grounding is an option, it is
subject to human error. In applications where
contamination is an issue, additives and carbon particles
used in static-dissipative materials may become sources
of contamination themselves.
R2-6.2 While charge is mobile in a conductor (or in a
static-dissipative material), in insulators charge is not
mobile, and earth grounding is not an effective means
of eliminating the static charge. More often than not,
the product itself uses insulating materials, making
earth grounding unavailable as an option. While silicon
is a semiconductor, its oxide coating transforms it into
an insulator. Polytetrafluoroethylene (PTFE) is used in
many chemical processes, and quartz in high-
temperature processes. Epoxy and ceramic packages
are used for integrated circuits. Insulators are easily
charged, retain their charge for long periods of time,
and are often close to the product.
R2-6.3 Dealing with static charge on insulators and
isolated conductors will often require the use of some
type of ionization or surface-resistance modification.
Ionizers are the most effective means of dealing with
static charges on insulators and isolated conductors if
the surface cannot be modified by coating or treatment
with some form of surface-dissipative or low-charging
“antistatic” agent.
R2-7 Ionization
R2-7.1 For purposes of static charge control, ions are
molecules of the gases in air (i.e., nitrogen, oxygen,
water vapor, carbon dioxide) that have lost or gained an
electron. Ions are present in normal outside air but are
removed when air is subjected to filtration and air
conditioning. Ionization systems work by increasing
the conductivity of the air by supplying ionized gas
molecules. Another way of looking at the application
of ionization is to interpret the function as supplying
opposite polarity charge from the air to surfaces
charged to the opposite polarity. When ionized air
comes in contact with a charged surface, the charged
surface attracts ions of the opposite polarity. As a
result, the static charge that has built up on products,
equipment and surfaces is neutralized.
R2-7.2 The most common methods of producing air
ions are radioisotopes and “corona discharge” resulting
from the electric field created when high voltage is
applied to a sharp point.
R2-7.3 The radioisotope most commonly used to
produce ionization is polonium-210, an alpha particle
emitter. The alpha particle collides with the
surrounding gas molecules, dislodging electrons. Gas
molecules that lose an electron become positive ions.
The free electron is quickly captured by another neutral
gas molecule, creating a negative air ion. Note that the
process always creates pairs of positive and negative
ions.
R2-7.4 The corona discharge method produces a very
high electric field that interacts with the electrons in the
surrounding gas. The polarity of the ions depends on
the polarity of the high voltage on the emitter point.
Ionizers using the corona discharge method will often
include some type of monitoring and feedback circuitry
to assure that equal numbers of positive and negative
ions are created.
R2-7.5 Ions of opposite polarity to the charged surface
are required. Either polarity of static charge may be
created on facility and equipment surfaces, or on the
product. Ionizers may be installed on the ceiling of the
room or may be hung from the ceiling using appropriate
mounting methods. Ionizers are installed in
minienvironments, particularly in the product load and
unload areas. Ionizers may also be installed in the
interior of process equipment. No single ionizer type or
installation location is sufficient to solve all the static
problems in the semiconductor facility.
R2-7.6 Ionizers should deliver ionization over a wide
range of humidity and temperature conditions. Back-
end assembly and test areas often do not have the level
of temperature and humidity control found in front-end
wafer production. Ionizers installed in the cramped
spaces of production equipment will be close to the
product, in areas surrounded by grounded metal parts.
Ionizers should isolate the emitter points from both the
product and adjacent grounded surfaces. Ionizers
should produce sufficient ions to discharge static on
surfaces and on products moving at high speeds despite
losses to ground. Most ionizers require maintenance
and periodic verification of their performance. The
appropriate ionizer installation will need to be
engineered for each specific application.
R2-8 Packaging Materials
R2-8.1 Types of Packaging
R2-8.1.1 Many forms of flexible and rigid packaging
are used to protect ESD-susceptible items. Bags,
boxes, wraps, tape and reel, pouches, cushioning foams,
totes, tubes and numerous other forms of containers are
available for any imaginable application. Each of these
container forms is available in an ESD-protective
version. Application in cleanroom environments adds
SEMI E129-1103 © SEMI 2003 21
additional requirements to the ESD-protective
packaging properties. Some of these considerations
may actually preclude the ability to provide ESD
protection. Therefore, there may often be a tradeoff
between ESD protection, cleanliness, and other required
material properties.
R2-8.1.2 The dissipative property for ESD protection
requires some type of chemical, metallic or elemental
additive to the bulk of the material or the surface of an
ESD-protective item. Adding a highly conductive layer
within the structure of the material or item provides the
electrostatic-shielding property. Any additive or
treatment may contribute to contamination concerns for
application in cleanrooms.
R2-8.1.3 Making a material low charging (“antistatic”)
requires modification of the surface to decrease surface
resistance and reduce friction. Often, low charging
materials allow a transfer of materials to contacting
surfaces to make the actual surfaces similar in
chemistry. Materials with chemically similar surfaces
usually do not show high levels of charge generation
when placed into contact and then separated from each
other. A downside to this process is the potential
contamination issue that may be involved if the
materials are used in clean areas. Take care in selecting
low-charging materials if cleanliness is a major issue.
This concern includes ionic contamination, non-
volatile-residue and outgassing.
R2-8.2 Material Guidelines
R2-8.2.1 Physical Guidelines — The required material
physical properties depend on the application involved.
The selection process for a packaging material or
system should consider all of the physical attributes
generally associated with protecting an item during
transit or storage. The physical requirements normally
evaluated for any packaging system and associated test
methods are shown in Table R2-1.
Table R2-1 Packaging System Physical Properties
Physical Properties Test Method
Tensile Strength ASTM D882
Elongation ASTM D882
Tear Strength ASTM D1922
Puncture Resistance FED-STD-101/2065
Seam Seal Strength (if
applicable)
ASTM F88
Light Transmission ASTM F1003
Moisture Vapor Transmission
(if applicable)
ASTM F1249
Light Transmission Rate (if
applicable)
ASTM D1003
R2-8.2.2 ESD-Protective Packaging Guidelines — The
type of packaging required for ESD-susceptible items
depends on where the item is going. Packaging
materials used inside of an ESD-protected work area
are static dissipative or low charging. When sensitive
items are moved outside of the protected area, the level
of protection should increase to include electrostatic
discharge shielding. Some extremely sensitive items
may require additional EMI or RFI protection provided
by heavier layers of shielding. Materials that provide
increased shielding may also provide moisture barrier
protection for enclosed items. The necessary electrical
properties for packaging materials that are normally
evaluated are shown with their associated test methods
in Table R2-2.
Table R2-2 ESD-Protective Packaging Properties
Electrical Properties Test Method
Surface Resistance ESD STM11.11
Volume Resistance ANSI ESD STM11.12
Shielding ANSI ESD S11.31
Static Decay FED-STD-101/4046
R2-8.2.3 Contamination Control Guidelines —
Contamination issues are not limited to particles.
Plastic processing additives to plastic packaging and
handling materials, chemical and molecular
compatibility should also be of concern. Users can
evaluate plastic packaging and handling materials using
published standard test methods. There are multiple
test methods and procedures to identify contamination
properties, as shown in Table R2-3. The user is advised
to select the method best suited to their products that
require protection.
Table R2-3 Contamination Control Properties
Contamination Properties Test Method
Particles ISO Std 14644
IEST-STD-CC1246D
IDEMA M9
ARP 598
KSC-C-123
Non-Volatile Residue IDEMA M7
ASTM E1235
ASTM F331
IPA extraction method
Outgassing IDEMA M11 Dynamic
Headspace Analysis
ASTM E595
Ionics IDEMA M12
Extractable/leachable cation
levels by ion chromatography