semi合集-English.pdf - 第991页
SEMI E131-0304 © SEMI 2004 1 SEMI E131-0304 SPECIFICATION FOR THE PHYSI CAL INTERFACE OF AN INTEGRATED MEASUREMENT MODU LE (IMM) INTO 300 mm TOOLS USING BOLTS-M This specification was technically approved by the Gl obal …

SEMI E129-1103 © SEMI 2003 28
R3-7 ACKNOWLEDGEMENT
Contributed by Vladimir Kraz, Credence Technologies,
3601-A Caldwell Drive, Soquel CA 95073,
vladimir@credencetech.com
NOTICE: SEMI makes no warranties or
representations as to the suitability of the standards set
forth herein for any particular application. The
determination of the suitability of the standard is solely
the responsibility of the user. Users are cautioned to
refer to manufacturer's instructions, product labels,
product data sheets, and other relevant literature,
respecting any materials or equipment mentioned
herein. These standards are subject to change without
notice.
By publication of this standard, Semiconductor
Equipment and Materials International (SEMI) takes no
position respecting the validity of any patent rights or
copyrights asserted in connection with any items
mentioned in this standard. Users of this standard are
expressly advised that determination of any such patent
rights or copyrights, and the risk of infringement of
such rights are entirely their own responsibility.
Copyright by SEMI® (Semiconductor Equipment and Materials
International), 3081 Zanker Road, San Jose, CA 95134. Reproduction o
f
the contents in whole or in part is forbidden without express written
consent of SEMI.

SEMI E131-0304 © SEMI 2004 1
SEMI E131-0304
SPECIFICATION FOR THE PHYSICAL INTERFACE OF AN
INTEGRATED MEASUREMENT MODULE (IMM) INTO 300 mm TOOLS
USING BOLTS-M
This specification was technically approved by the Global Physical Interfaces & Carriers Committee and is
the direct responsibility of the North American Physical Interfaces & Carriers Committee. Current edition
approved by the North American Regional Standards Committee on December 4, 2003. Initially available at
www.semi.org February 2004; to be published March 2004.
1 Purpose
1.1 This document establishes the specification for the
interface requirements between an integrated
measurement module (IMM) and 300 mm tools using
an interface as defined by SEMI E63 (BOLTS-M).
NOTE 1: The 1997 and 2000 SIA roadmaps call for the
implementation of metrology integrated with process tools.
Such technology is important as specifications tighten the cost
of monitor substrates at larger size increases, and as materials
and processing steps become more complex.
NOTE 2: The 300 mm equipment generation offers an
opportunity for integration of measurement equipment
modules in a configuration that could be standard across
different tools.
1.2 The standard will permit the tool suppliers, robotics
suppliers, and measurement module suppliers, to
provide plug and play integrated measurement solutions
on a mechanical level.
1.3 It is the purpose of this standard to facilitate
process monitoring through rapid access to
measurement data, to reduce material handling between
process and measurement equipment, and to provide the
opportunity to increase process monitoring with a
minimum or no decrease in throughput.
2 Scope
2.1 This standard is intended to set an appropriate level
of specification that places minimal limits on
innovation while ensuring modularity and
interoperability at all mechanical interfaces. It
establishes the mechanical interface specifications for
integration of measurement modules intended for, but
not limited to, 300 mm process tools using a BOLTS-M
interface, while utilizing existing SEMI Standards as
much as possible.
2.2 This standard specifies that SEMI E63 is utilized
for the tool side of the interface.
2.3 This standard covers the following topics:
• General physical requirements for integration of
the IMM,
• Nominal wafer-seating plane within the IMM,
• Maximum outer dimensions of the IMM, in case it
is located at the front of a tool.
NOTICE: This standard does not purport to address
safety issues, if any, associated with its use. It is the
responsibility of the users of this standard to establish
appropriate safety and health practices and determine
the applicability of regulatory or other limitations prior
to use.
3 Limitations
3.1 This standard does not specify the location of the
IMM relative to the tool.
3.2 This standard does not specify facility or
communication interfaces.
3.3 No materials requirements or micro-contamination
limits are given.
3.4 Substrate input and retrieval will be the obligation
of the tool.
4 Referenced Standards
4.1 SEMI Standards
SEMI E1.9 — Mechanical Specification for Cassettes
Used to Transport and Store 300 mm Wafers
SEMI E15 — Specification for Tool Load Port
SEMI E15.1 — Specification for 300 mm Tool Load
Port
SEMI E47.1 — Provisional Mechanical Specification
for Boxes and Pods Used to Transport and Store 300
mm Wafers
SEMI E57 — Mechanical Specification for Kinematic
Couplings Used to Align and Support 300 mm Carriers
SEMI E63 — Mechanical Specification for 300 mm
Box Opener/Loader to Tool Standard (BOLTS-M)
Interface
SEMI E64 — Specification for 300 mm Cart to SEMI
E15.1 Docking Interface Port

SEMI E131-0304 © SEMI 2004 2
SEMI E127 — Specification for Integrated
Measurement Module Communications: Concepts,
Behavior, and Services (IMMC)
NOTICE: Unless otherwise indicated, all documents
cited shall be the latest published versions.
5 Terminology
5.1 Abbreviations and Acronyms
5.1.1 IMM — Integrated Measurement Module
5.2 Definitions
5.2.1 bilateral datum plane — a vertical plane that
bisects the substrates and that is perpendicular to both
the horizontal and facial datum planes. (As defined in
SEMI E57.)
5.2.2 BOLTS plane — a plane parallel to the facial
datum plane near the front of the tool where the
box/opener loader is attached. (As defined in SEMI
E63.)
5.2.3 facial datum plane — a vertical plane that bisects
the wafers and that is parallel to the front side of the
carrier (where wafers are removed or inserted). On tool
load ports, it is also parallel to the load face plane
specified in SEMI E15 on the side of the tool where the
carrier is loaded and unloaded. (As defined in SEMI
E57.)
5.2.4 horizontal datum plane — a horizontal plane
from which projects the kinematic-coupling pins on
which the carrier sits. On tool load ports, it is at the
load height specified in SEMI E15 and might not be
physically realized as a surface. (As defined in SEMI
E57.)
5.2.5 integrated measurement module (IMM) — a
measurement module intended to be integrated into
manufacturing equipment, and with the capability of
receiving substrates from the equipment, measuring
those substrates, and returning the substrates and the
measurement results to the equipment and other
concerned clients. (As defined in SEMI E127.)
5.2.6 measurement module — an equipment module
whose intended function is to measure or inspect the
product and to report the results. Measurement of the
product is the factory’s means of gaining feedback on
the manufacturing process. (As defined in SEMI
E127.)
5.2.7 nominal wafer-seating plane — horizontal plane
that bisects the wafer pick-up volume. (As defined in
SEMI E1.9.)
6 Requirements
6.1 The IMM is required to mate with an interface as
defined by SEMI E63. This includes meeting the
requirements for the hole opening, bolt hole pattern,
and other relevant requirements. Note that certain
requirements in SEMI E63, such as y76 (facial datum
plane when carrier is undocked), do not have relevance
for the IMM but will not be in conflict.
6.2 Use of Datum Planes — The location in space
where a substrate is delivered to an IMM is the
intersection of three orthogonal datum planes defined in
other standards: the facial datum plane, the nominal
wafer-seating plane and the bilateral datum plane. The
BOLTS plane, as in SEMI E63, is defined to be parallel
to, and at a distance of y70 from the facial datum plane.
6.2.1 Bilateral Datum Plane — All bilateral
dimensions of the interface are symmetric about the
bilateral datum plane as shown in Figure 1.
6.2.2 Facial Datum Plane — This is the vertical plane,
parallel to the BOLTS plane, which bisects the
substrate at the insertion and removal position of the
substrate inside of the IMM. The distance from the
BOLTS plane to the facial datum plane in the IMM is
determined by y70 of SEMI E63.
6.2.3 Nominal Wafer-Seating Plane — The nominal
wafer-seating plane is the horizontal plane within the
IMM where a substrate is to be loaded to or unloaded
from by the tool. It can be anywhere between the given
minimum and maximum values that follow. This range
is not defined by a single standard, rather it results from
a combination of dimensions of SEMI E1.9, SEMI
E15.1 and SEMI E47.1. (See Figure 1.)
6.2.3.1 The minimum value for a nominal wafer-
seating plane is the sum of (H + z44 + z8), measured
from the floor.
6.2.3.2 The maximum value for a nominal wafer-
seating plane is calculated by (H + z44 + z8 + (25-1) *
z12), measured from the floor.
6.2.3.3 For both calculations, H is from SEMI E15.1,
z44 is from SEMI E47.1, and z8 and z12 are from
SEMI E1.9.
6.3 Internal Clearances — There are requirements
relating to clearances inside the IMM. These relate to
robot arm requirements for substrate handoff, and can
be referenced from SEMI E1.9 and SEMI E47.1 as the
same restrictions apply.
6.3.1 This includes clearance in front of the wafer set-
down location of radius r3, and heights bounded by z11
and z10 relative to the nominal wafer-seating plane.
All clearance requirements above the highest and below
the lowest slot from SEMI E1.9 and SEMI E47.1 must