semi合集-English.pdf - 第5967页
SEMI P41-0304 E © SEMI 2004 27 <ImageReference origin = "mask origin"> <ImageReferencePoint >center</ImageReferencePoint> < I m a g e R e f e r e n c ePosition unit = "micron">…

SEMI P41-0304
E
© SEMI 2004 26
<ImageGrayLevel></ImageGrayLevel>
</ImageInformation>
<ImageIllumination></ImageIllumination>
<ImageRotation></ImageRotation>
<ImageMirror></ImageMirror>
<ImageFlip></ImageFlip>
<ImageConvertInformation>
<ImageContrast></ImageContrast>
<ImageBrightness></ImageBrightness>
<ImageConversionParameter></ImageConversionParameter>
</ImageConvertInformation>
<ImageReference origin = "">
<ImageReferencePoint></ImageReferencePoint>
<ImageReferencePosition unit = "">
<ImageReferencePosition_X></ImageReferencePosition_X>
<ImageReferencePosition_Y></ImageReferencePosition_Y>
</ImageReferencePosition>
</ImageReference>
<ImageTarget origin = "">
<ImageTargetPosition unit = "">
<ImageTargetPosition_X></ImageTargetPosition_X>
<ImageTargetPosition_Y></ImageTargetPosition_Y>
</ImageTargetPosition>
<ExpressionMark></ExpressionMark>
</ImageTarget>
</ImageData>
</DefectRepair>
<DefectEvaluate date_stamp = "19:30:00 03-sep-2003">
<EvaluationRecipe recipe_name = "recipe003">
<EvaluationCondition>parameter1-000 parameter2-000</EvaluationCondition>
</EvaluationRecipe>
<EvaluateResult>OK</EvaluateResult>
<ImageData>
<ImageReferenceAdress>D:\review\image\image001.bmp</ImageReferenceAdress>
<ImageInformation>
<ImageFormat>bitmap</ImageFormat>
<ImageMagnification>10000</ImageMagnification>
<ImagePixelNumber_X>2048</ImagePixelNumber_X>
<ImagePixelNumber_Y>2048</ImagePixelNumber_Y>
<ImagePixelSize unit = "nanometor">
<ImagePixelSize_X>10</ImagePixelSize_X>
<ImagePixelSize_Y>10</ImagePixelSize_Y>
</ImagePixelSize>
<ImageGrayLevel>256</ImageGrayLevel>
</ImageInformation>
<ImageIllumination>transmission</ImageIllumination>
<ImageRotation>none</ImageRotation>
<ImageMirror>y-mirror</ImageMirror>
<ImageFlip>none</ImageFlip>
<ImageConvertInformation>
<ImageContrast>230/256</ImageContrast>
<ImageBrightness>230/256</ImageBrightness>
<ImageConversionParameter>convert 8bit from 12bit</ImageConversionParameter>
</ImageConvertInformation>

SEMI P41-0304
E
© SEMI 2004 27
<ImageReference origin = "mask origin">
<ImageReferencePoint>center</ImageReferencePoint>
<ImageReferencePosition unit = "micron">
<ImageReferencePosition_X>86200</ImageReferencePosition_X>
<ImageReferencePosition_Y>76200</ImageReferencePosition_Y>
</ImageReferencePosition>
</ImageReference>
<ImageTarget origin = "LeftTop">
<ImageTargetPosition unit = "pixel">
<ImageTargetPosition_X>1024</ImageTargetPosition_X>
<ImageTargetPosition_Y>1024</ImageTargetPosition_Y>
</ImageTargetPosition>
<ExpressionMark>square box</ExpressionMark>
</ImageTarget>
</ImageData>
</DefectEvaluate>
</Defect>
</InspectionResut>
</MDML>
NOTICE: SEMI makes no warranties or representations as to the suitability of the standards set forth herein for any
particular application. The determination of the suitability of the standard is solely the responsibility of the user.
Users are cautioned to refer to manufacturer's instructions, product labels, product data sheets, and other relevant
literature, respecting any materials or equipment mentioned herein. These standards are subject to change without
notice.
By publication of this standard, Semiconductor Equipment and Materials International (SEMI) takes no position
respecting the validity of any patent rights or copyrights asserted in connection with any items mentioned in this
standard. Users of this standard are expressly advised that determination of any such patent rights or copyrights, and
the risk of infringement of such rights are entirely their own responsibility.
Copyright by SEMI® (Semiconductor Equipment and Materials
International), 3081 Zanker Road, San Jose, CA 95134. Reproduction of
the contents in whole or in part is forbidden without express written
consent of SEMI.

SEMI P42-0304 © SEMI 2004 1
SEMI P42-0304
SPECIFICATION OF RETICLE DATA FOR AUTOMATIC RECIPE
TRANSFER TO WAFER EXPOSURE SYSTEM
This specification was technically approved by the Global Micropatterning Committee and is the direct
responsibility of the Japanese Micropatterning Committee. Current edition approved by the Japanese
Regional Standards Committee on January 9, 2004. Initially available at www.semi.org February 2004; to be
published March 2004.
1 Purpose
1.1 This specification defines a common data interface,
which consists of frame information of reticle data, in
order to prepare recipes for wafer exposure tools. By
utilizing this interface, it becomes possible to carry out
data handling between design and wafer manufacture so
that the data can be reused during recipe making of
wafer exposure tools. This standard is intended to
assist automatic recipe generation of wafer exposure
tools.
2 Scope
2.1 This standard details frame information in
automatic recipe preparation for wafer exposure
equipment. This standard focuses on communication
interface in work flow of design, mask manufacturing,
and wafer manufacturing processes.
2.1.1 This standard defines the items of the required
and common design information at a reticle design and
a recipe preparation for wafer exposure equipment.
2.1.2 This standard defines a data interface, which can
be commonly used independently to the suppliers and
models of exposure equipment.
NOTICE: This standard does not purport to address
safety issues, if any, associated with its use. It is the
responsibility of the users of this standard to establish
appropriate safety and health practices and determine
the applicability of regulatory or other limitations prior
to use.
3 Limitations
3.1 This data interface is expandable (an item addition
and a user definition are enabled) instead of fixed, and
serves as a form with flexibility.
3.2 This standard uses the current XML standard to
describe a reticle data interface.
3.3 This standard does not provide the definition of the
handling interface of device design data. Only the data
interface specific to frame data information is defined.
3.4 The wafer map information by reticle frame data
and the wafer, which exposure equipment uses, are
defined in this standard.
3.5 This standard includes the handling items of the
related information for reticle exposure and a mark
formation process (reticle) required for automatic recipe
preparation.
3.6 Recipe preparation is shown in Figure 1. This
document focuses on reticle data management (RDM)
interface (IF) as indicated in Figure 1.
4 Referenced Standards
4.1 JEITA Documents
1
Reticle Data Management Guideline Ver.1.0 (2001) —
(http://jeita-smtc.elisasp.net/)
4.2 World Wide Web Consortium Documents
2
Extensible Markup Language (XML) 1.0 (Second
Edition) — W3C,6 October 2000
(
http://www.w3.org/TR/2000/REC-xml-20001006)
Extensible Markup Language (XML) 1.1 — W3C,15
October 2002 (
http://www.w3.org/TR/2002/CR-xml11-
20021015)
Extensible Markup Language (XML) 1.1 ― 15 October
2002, John Cowan (
http://www.w3.org/TR/2002/CR-
xml-names11-20021218/)
Namespaces in XML — W3C, 14 January 1999
(
http://www.w3.org/TR/1999/REC-xml-names-
19990114/)
XML Schema Part 0: Primer — W3C, 2 May 2001
(
http://www/w3/org/TR/xmlschema-0/)
XML Schema Part 1: Structures — W3C, 2 May 2001
(
http://www/w3/org/TR/xmlschema-1/)
XML Schema Part 2: Datatypes — W3C, 2 May 2001
(
http://www/w3/org/TR/xmlschema-2/)
1 Japanese Electronic and Information Technology Industries
Association, Tokyo Chamber of Commerce and Industry Bldg. 2-2,
Marunouchi 3-chome, Chiyoda-ku, Tokyo 100-0005, Japan. Website:
http://www.jeita.or.jp
2 World Wide Web Consortium (W3C), ,Website:
http://www.w3c.or
g