SEMI E87-0705 © SEMI 1999, 2005 45 Variable Name Desc ription Type Acc ess Comment Reason The reason for transition 14, SLOT MAP NOT READ to WAITING FOR HOST. Enumerated: VERIFICATION NEEDED, VERIFICATION BY EQUIPMENT UN…

SEMI E87-0705 © SEMI 1999, 2005 44
Variable Name Description Type Acc
ess
Comment
PartitionType The type of a logical partition
within an internal buffer.
Text RO Only applicable to internal
buffer production equipment.
Some examples of logical
buffer PartitionType are
Product, Dummy, Substrate,
and Seed.
PartitionType
i
The PartitionType corresponding
with the i
th
PartitionID.
Text RO Only applicable to internal
buffer production equipment.
Some examples of logical
buffer PartitionType are
Product, Dummy, Substrate,
and Seed.
PortAssociationState The association state of a load
port.
Enumerated:
ASSOCIATED,
NOT ASSOCIATED
RO
PortAssociationState
i
The association state of the i
th
load
port.
Enumerated:
ASSOCIATED,
NOT ASSOCIATED
RO
PortAssociationState-
List
The current association state for
all load ports.
A list of n items
1. PortAssociationState
1
.
.
n. PortAssociationState
n
RO This can be used to re-
synchronize the host.
PortID ID of a load port. Positive integer RO
PortID
i
ID of the load port where the
carrier transfer is taking place.
One PortID exists for each load
port.
Positive integer RO
PortStateInfo The PortAssociationState
combined with the
PortTransferState.
List of 2 items
PortAssociationState
PortTransferState
RO A combination of both port
states.
PortStateInfo
i
The PortAssociationState
combined with the
PortTransferState for the i
th
load
port.
List of 2 items
PortAssociationState
i
PortTransferState
i
RO A combination of both port
states.
PortStateInfoList List of PortStateInfo for all load
ports.
List of n items
1. PortStateInfo
1
.
.
n PortStateInfo
n
RO A list of all the port states for
all the ports.
PortTransferState The current transfer state of a load
port.
Enumerated:
OUT OF SERVICE,
TRANSFER BLOCKED,
READY TO LOAD,
READY TO UNLOAD
RO Super states are not included,
only sub states.
PortTransferState
i
The current transfer state of the i
th
load port.
Enumerated:
OUT OF SERVICE,
TRANSFER BLOCKED,
READY TO LOAD,
READY TO UNLOAD
RO Super states are not included,
only sub states.
PortTransferStateList The current Load Port Transfer
State for all load ports.
A list of n items
1. PortTransferState
1
.
.
n. PortTransferState
n
RO This can be used to re-
synchronize the host.

SEMI E87-0705 © SEMI 1999, 2005 45
Variable Name Description Type Acc
ess
Comment
Reason The reason for transition 14,
SLOT MAP NOT READ to
WAITING FOR HOST.
Enumerated:
VERIFICATION NEEDED,
VERIFICATION BY
EQUIPMENT
UNSUCCESSFUL,
READ FAIL,
IMPROPER SUBSTRATE
POSITION
RO Information to aid host in
deciding appropriate action.
SlotMapStatus State of the carrier slot map status. Enumerated:
SLOT MAP NOT READ,
[SLOT]WAITING FOR
HOST,
SLOT MAP
VERIFICATION OK,
SLOT MAP
VERIFICATION FAILED
RO
UnAllocatedPartition-
Capacity
The current unallocated capacity
for a logical partition inside
internal buffer equipment,
(PartitionCapacity - # of carriers
in partition - # of carriers allocated
for the partition (via reception of a
Bind, CarrierIn,
CarrierNotification,
ReserveAtPort, or
ProceedWithCarrier service). Any
carriers allocated for a partition
will be de-allocated if the
corresponding Cancel service is
received (for example Bind-
CancelBind, CarrierNotification –
CancelCarrierNotification,
ReserveAtPort –
CancelReservationAtPort,
ProceedWithCarrier –
CancelCarrier).
Non-negative integer RO Only applicable to internal
buffer equipment.
UnAllocatedPartition-
Capacity
i
The UnallocatedPartitionCapacity
for the i
th
Partition ID within the
internal buffer
Non-negative integer RO Only applicable to internal
buffer equipment.
20 Alarms
20.1 This section includes specific alarms that are required to be implemented by CMS compliant equipment.
20.2 Alarm List Table
20.2.1 Table 38 is a listing of required alarms for both fixed buffer and internal buffer equipment. This list is only a
subset of the carrier transfer alarms. There may be more carrier transfer related alarms that are not listed here.
Table 38 Alarm List
Equipment Danger Affected
Configuration Alarm Text Potential Imminent Operator Equipment Material
Fixed & Internal
Buffer Equipment
PIO Failure X X X X
Access Mode Violation X X X X

SEMI E87-0705 © SEMI 1999, 2005 46
Equipment Danger Affected
Configuration Alarm Text Potential Imminent Operator Equipment Material
Carrier Verification Failure X X
Slot Map Read Failed X X X X
Slot Map Verification Failed X X X
Attempt To Use Out Of Service Load Port X X X
Carrier Presence Error X X X X
Carrier Placement Error X X X X
Carrier Dock/UnDock Failure X X X
Carrier Open/Close Failure X X X
Fixed and Internal
Buffer
Duplicate CarrierID X X
Internal Buffer
Equipment Only
Internal Buffer Carrier Move Failure X X X
Fixed & Internal
Buffer Equipment
Carrier Removal Error X X X X
20.3 Duplicate CarrierID
20.3.1 If the equipment receives a carrier with a CarrierID that is the same as that of another carrier present at the
equipment, the following rules shall apply:
1. The second carrier with a CarrierID shall not be processed.
2. If processing on the first carrier with the CarrierID has not begun, it should not be processed.
3. If processing on the first carrier has begun a Duplicate Carrier ID In Process event shall be issued to notify the
host.
21 Requirements for Compliance
21.1 Table 39 provides a checklist for CMS compliance.
Table 39 CMS Compliance Statement
Fundamental CMS Requirements CMS Section Implemented CMS Compliant
Load Port Numbering 9.1 Yes No Yes No
Carrier Slot Numbering 9.2 Yes No Yes No
Load Port Transfer State Model 9.3–9.4.3 Yes No Yes No
Carrier Object Implementation 10 Yes No Yes No
Load Port Reservation State Model
(internal buffer equipment)
12 Yes No Yes No
Load Port/Carrier Association State Model 13 Yes No Yes No
CarrierID Verification Support 14.2 Yes No Yes No
Slot Map Verification Support 14.3 Yes No Yes No
Services Implementation 16 Yes No Yes No
Additional Events Implementation 18 Yes No Yes No
Variable Data Definitions 19 Yes No Yes No
Alarms Implementation 20 Yes No Yes No
Additional CMS Capabilities CMS Section Implemented CMS Compliant
Load Port Reservation State Model
(fixed buffer equipment)
12 Yes No Yes No
Reservation Visible Signal 12.2 Yes No Yes No