semi合集-English.pdf - 第1981页
SEMI E54.4-0704 © SEMI 1997, 2004 16 OBJECT NAME Sensor Actuator Controller OBJECT ID 66 Object Class ID Description Get Set Value Limits Attributes Open _____ ____________________ ❑ ❑ ___________________ _____ _________…

SEMI E54.4-0704 © SEMI 1997, 2004 15
OBJECT NAME Device Manager
OBJECT ID 64
Object Class ID Description Get Set Value Limits
Attributes Open _____ ________________ ❑ ❑ ___________________
DeviceNet Services Parameter Options
Services ____________________________ ____________________________
DeviceNet
Open
Object
Implementation
Object Instance ID Description Get Set Value Limits
Attributes Open 31 Device Type ❑ ❑ ___________________
32 Standard Revision Level ❑ ❑ ___________________
33 Device Manufacturer ID ❑ ❑ ___________________
34 Manufacturer Model Number ❑ ❑ ___________________
35 Soft/Firmware Rev. Level ❑ ❑ ___________________
36 Hardware Revision Level ❑ ❑ ___________________
37 Serial Number ❑ ❑ ___________________
38 Device Configuration ❑ ❑ ___________________
39 Device Status ❑ ❑ ___________________
3A Reporting Mode ❑ ❑ ___________________
3B Exception Status Timer ❑ ❑ ___________________
3C Exception Status ❑ ❑ ___________________
3D Exception Detail Alarm ❑ ❑ ___________________
3E Exception Detail Warning ❑ ❑ ___________________
DeviceNet Services Parameter Options
Services ❑ Reset ____________________________
❑ Abort ____________________________
❑ Recover ____________________________
❑ Get_Attribute_Single ____________________________
❑ Set_Attribute_Single ____________________________
❑ Execute ____________________________
❑ Perform Diagnostics ____________________________
Meaning of Zero Length I/O Data Production______________________________________________
Vendor-Specific Additions
If yes, fill out the Vendor-Specific Yes ❑
Additions form on page F_7. No ❑
X Get to indicate that attribute value is returned by the use of Get_Attribute_Single service.
X Set to indicate that attribute value is written by the use of Set_Attribute_Single service.
F_ 6

SEMI E54.4-0704 © SEMI 1997, 2004 16
OBJECT NAME Sensor Actuator Controller
OBJECT ID 66
Object Class ID Description Get Set Value Limits
Attributes Open _____ ____________________ ❑ ❑ ___________________
_____ ____________________ ❑ ❑ ___________________
DeviceNet
Open
Object
Implementation
_____ ____________________ ❑ ❑ ___________________
DeviceNet Services Parameter Options
Services _______________________________ ____________________________
_______________________________ ____________________________
_______________________________ ____________________________
Object Instance ID Description Get Set Value Limits
Attributes Open _______________________________ ❑ ❑ ___________________
_______________________________ ❑ ❑ ___________________
_______________________________ ❑ ❑ ___________________
DeviceNet Services Parameter Options
Services ❑ Reset ____________________________
❑ Abort ____________________________
❑ Recover ____________________________
❑ Get_Attribute_Single ____________________________
❑ Set_Attribute_Single ____________________________
_______________________________ ____________________________
_______________________________ ____________________________
_______________________________ ____________________________
Meaning of Zero Length I/O Data Production____________________________________________________
Vendor-Specific
Additions
If yes, fill out the Vendor-Specific Yes ❑
Additions form on page F_7. No ❑
X Get to indicate that attribute value is returned by the use of Get_Attribute_Single service.
X Set to indicate that attribute value is written to by the use of Set_Attribute_Single service.
F_ 7

SEMI E54.4-0704 © SEMI 1997, 2004 17
DeviceNet OBJECT NAME____________________________________________ OBJECT ID_________________
Object Class ID Description Get Set Value Limits
Attributes Open _____ ____________________ ❑ ❑ ___________________
_____ ____________________ ❑ ❑ ___________________
Open
Object
Implementation
_____ ____________________ ❑ ❑ ___________________
DeviceNet Services Parameter Options
Service _______________________________ ____________________________
_______________________________ ____________________________
_______________________________ ____________________________
Object Instance ID Description Get Set Value Limits
Attributes Open 1 ___________________________ ❑ ❑ ___________________
2 ___________________________ ❑ ❑ ___________________
3 ___________________________ ❑ ❑ ___________________
DeviceNet Services Parameter Options
Services _______________________________ ____________________________
_______________________________ ____________________________
_______________________________ ____________________________
Meaning of Zero Length I/O Data Production____________________________________________________
Vendor-SpecificAdditions If yes, fill out the Vendor-Specific Yes ❑
Additions form on page F_7. No ❑
X Get to indicate that attribute value is returned by the use of Get_Attribute_Single service.
X Set indicate that attribute value is written to by the use of Set_Attribute_Single service.
F_ 8