SEMI E109-0305 © SEMI 2001, 2005 61 Variable Name Descripti on Type Access Comment Reject Reason The reason a reticle is rejected. Enumerated: ID Verification failedParticle qualifi cation failed Rejected By Host Rejecte…

SEMI E109-0305 © SEMI 2001, 2005 60
Variable Name Description Type Access Comment
PortAssociationState
i
The association state of the i
th
load port.
Enumerated:
ASSOCIATED,
NOT ASSOCIATED
RO
PortAssociationState-
List
The current association state
for all load ports.
A list of n items
1. PortAssociationState
1
.
.
n. PortAssociationState
n
RO This can be used to re-
synchronize the host.
PortID ID of a load port. Positive integer RO
PortID
I
ID of the load port where the
pod transfer is taking place.
One PortID exists for each
load port.
Positive integer RO
PortStateInfo The PortAssociationState
combined with the
PortTransferState.
List of 2 items
PortAssociationState
PortTransferState
RO A combination of both port
states.
PortStateInfo
i
The PortAssociationState
combined with the
PortTransferState for the i
th
load port.
List of 2 items
PortAssociationState
i
PortTransferState
i
RO A combination of both port
states.
PortStateInfoList List of PortStateInfo for all
load ports.
List of n items
1. PortStateInfo
1
.
.
n PortStateInfo
n
RO A list of all the port states for
all the ports.
PortTransferState The current transfer state of a
load port.
Enumerated:
OUT OF SERVICE,
TRANSFER BLOCKED,
READY TO LOAD, READY
TO UNLOAD
RO Super states are not included,
only sub states.
PortTransferState
i
The current transfer state of
the i
th
load port.
Enumerated:
OUT OF SERVICE,
TRANSFER BLOCKED,
READY TO LOAD, READY
TO UNLOAD
RO Super states are not included,
only sub states.
PortTransferStateList The current Load Port
Transfer State for all load
ports.
A list of n items
1. PortTransferState
1
.
.
n. PortTransferState
n
RO This can be used to re-
synchronize the host.
Reason The reason for transition 15,
SLOT MAP NOT READ to
WAITING FOR HOST.
Enumerated:
VERIFICATION NEEDED,
VERIFICATION BY
EQUIPMENT
UNSUCCESSFUL,
READ FAIL,
IMPROPER WAFER
POSITION
RO Information to aid host in
deciding appropriate action.

SEMI E109-0305 © SEMI 2001, 2005 61
Variable Name Description Type Access Comment
Reject Reason The reason a reticle is
rejected.
Enumerated:
ID Verification
failedParticle qualification
failed
Rejected By Host
Rejected By Operator
Inspection Results Expired
RO Information to aid the host in
understanding why a reticle is
rejected.
#1
These are defined in the Alarm Information table.
#2
For all the variables defined as lists of port information (such as states), the port information should be placed in the list in numerical order by
PortID, from lowest to highest.
22 Alarms
22.1 This section includes specific alarms that are required to be implemented by RPMS compliant equipment.
22.2 Alarm List Table
22.2.1 Table 57 is a listing of required alarms for both fixed buffer and internal buffer equipment. This list is only a
subset of the pod transfer alarms. There may be more pod transfer related alarms that are not listed here.
Table 57 Alarm List
Equipment Danger Affected
Configuration Alarm Text Potential Imminent Operator Equipment Material
Fixed & Internal
Pod Buffer
Equipment
PIO Failure X X X X
Access Mode Violation X X X X
Attempt To Use Out Of Service Load Port X X X
Pod Placement Error X X X X
Pod Open/Close Failure X X X
Fixed and Internal
Pod Buffer
Equipment
Duplicate PodID X X
Fixed & Internal
Pod Buffer
Equipment
Pod Removal Error X X X X
Duplicate Reticle
ID
A duplicate reticle is detected. X X
Pod Pick/Place
error
The internal robot that moves the Pods failed
to pick or place a pod. Can be triggered if the
state of the system after a pick or place is
inconsistent (i.e., both robot and pod think
they are empty).
X X X
Reticle Pick/Place
error
The internal robot that moves the reticles
failed to pick or place a reticle. Can be
triggered if the state of the system after a pick
or place is inconsistent (i.e. both robot and
pod think they are empty).
X X X
Automation Error Automation errors that do not fit other
categories have been detected.
X X X X

SEMI E109-0305 © SEMI 2001, 2005 62
22.3 Alarm Usage
22.3.1 Reticle and Pod Management requires standardization on the alarm codes. Many errors may be mapped to a
sinlge “generic” alarm code. In this case, the recovery scenario would be the same but the alarm text shall contain a
more descriptive explanation of the error. For example, the Pod Open/Close alarm can be caused by many different
opener errors.
22.3.2 This alarm applies to both Fixed and Internal Pod Buffer Equipment.
22.3.3 For any load port Alarm condition, process equipment should not stop processing current jobs.
Table 58 Alarm Information
Alarm Description Alarm
Number
Auto
Clear
Set trigger Clear Trigger
PIO Failure 1 NO E84 error. Manual intervention
Access Mode Violation
(unexpected load)
2 NO Operator places pod on load port with access
mode set to auto.
Operator switches to manual
Operator removes the pod
Operator switches to auto
Operator clears alarm at UI
Access Mode
Violation
(unexpected unload)
NO Operator takes a pod off load port with
access mode set to auto.
Operator clears alarm at UI
Attempt to use out of
service load port
3 YES Pod placed on load port with transfer state
set to out-of-service.
Pod is removed
Pod placement/placement
error
4 YES Sensors detect pod is not properly placed at
pod opener.
Sensors detect pod is properly
placed at pod opener or no pod
present
Pod Open/Close error 5 NO Opener errors while opening or closing. Manual intervention
Duplicate Pod ID 6 Yes A duplicate pod is detected. Methods vary by equipment
type
Pod Removal Error 7 NO Pod removed before the Pod is in the
READY TO UNLOAD state.
Operator clears alarm at UI
Duplicate Reticle ID 8 YES A duplicate reticle is detected. Methods vary by equipment
type
Pod Pick/Place error 9 NO The internal robot that moves the Pods
failed to pick or place a pod. Can be
triggered if the state of the system after a
pick or place is inconsistent (i.e. both robot
and pod think they are empty).
Manual intervention
Reticle Pick / Place error 10 NO The internal robot that moves the reticles
failed to pick or place a reticle. Can be
triggered if the state of the system after a
pick or place is inconsistent (i.e. both robot
and pod think they are empty).
Manual intervention
Automation Error 11 NO Equipment and Alarm dependent, alarms
that do not fit other categories.
Manual intervention
22.4 Duplicate PodID at Production Equipment
22.4.1 If the equipment receives a pod with a PodID that is the same as that of another pod present at the
equipment, the following rules shall apply:
1. The second pod with a PodID shall not be processed.