SEMI F46-0999 © SEMI 1999 4 8.6 Filtration Optio ns Recircul a t i on filtratio n of either QC tanks or the Product storag e tank is importan t to control particle levels in the final chemical. Recirculation filtration…

SEMI F46-0999 © SEMI 19993
and/or company codes.
7.3.4 An appropriate component design must be used
for the gas/liquid interface(s).
7.4 The OSCG System The appropriate OSCG
system will be defined based on overall capacity
requirements.
7.4.1 The OSCG system can provide feed gas
purification and chemical generation within a stand
alone packaged unit or use externally purified feed
gases. Optional Feed gas purification may also be
provided in this package.
7.4.2 The OSCG system will have a dedicated control
system to control all process parameters and monitor all
system safety interlocks including external safety
systems.
7.4.3 The OSCG will provide pressurized chemical to
the Product Quality verification subsystem.
7.5 Product Quality Verification All OSCG
installation will include some type of Product sampling
and quality verification scheme.
7.5.1 The standard quality verification scheme will
provide for an in-line, “Clean Sample” station to allow
for random samples to be taken for analysis.
7.5.2 A SPC quality assurance scheme can be utilized
to track and record product chemical purity and assay
guides. Readings are plotted using X-bar/R format and
reacted to based on standard SPC rules.
7.5.3 In this scheme product chemical is transferred to
the Product storage tank directly from the OSCG
system, through the sampling subsystem or directly to
chemical delivery systems.
7.6 Product Storage All OSCG implementation
will include a Product chemical storage scheme to
ensure chemical availability to the customer.
7.6.1 Product storage is achieved, typically, by
including an appropriately sized storage tank. This tank
becomes the source to the chemical distribution system.
7.6.2 Product storage volume is defined to provide
suitable inventory of product chemical storage. This
will provide chemical available to the distribution
system during periods of both scheduled and
unscheduled maintenance.
7.6.3 Additionally, a back-up supply of prequalified
chemical may be available to transfer into the Product
tank, if required.
7.7 Central Monitoring System A central CPU
based monitoring system is required for multiple
purposes in the overall implementation.
7.7.1 The central CPU will communicate with all
subsystems and tanks to share information, as required,
to ensure total system operations.
7.7.2 The central CPU also provides data logging and
database features to track and log product quality and
system failure data as required.
7.7.3 The central CPU can also provide a remote
monitoring feature and interface with the customer’s
facility tracking system (if desired).
8 Optional Configurations and Support
Systems
8.1 Feed Gas Supply Some customers may already
have an existing source of an appropriate Feed gas for
the OSCG system. Implementation schemes can be
configured to utilize this existing gas storage and
supply system. The existing system will need to meet
the vendors guides for gas purity and line pressures.
8.2 Product Storage and Staging Tanks Some
customers may already have tanks that can be used for
Product Storage and/or staging applications.
Implementation schemes can be configured to utilize
these existing storage tanks. The existing tanks must
meet vendors guides for materials, inlets/outlets, and
volume. Level sensor data will be provided to the
central CPU system.
8.3 Multiple OSCG Systems Depending on capacity
requirements, OSCG installations can be configured to
have multiple Generator systems in parallel. All
product outputs should have the capability to be
sampled individually before combining into a common
product stream for storage.
8.4 Support Systems Various support systems and
options can be provided to support the overall
implementation scheme.
8.4.1 Stand-alone, water-cooled Chiller(s) may be
required, if the house chilled water is not available.
8.4.2 Redundant pump options should be available in
any pumping system to allow for either manual switch
over or automatic back-up.
8.4.3 Transfer pumping systems or transfer options
should be available for the transfer of chemical from or
to remote storage tanks.
8.5 Chemical Distribution Chemical distribution
systems may or may not be in existence at specific
customer sites. The distribution of chemical from the
product storage to use points will be important to
maintain chemical purity. These distribution systems
should be available as a directly supplied option or
offered through a sub-contracted supplier.

SEMI F46-0999 © SEMI 1999 4
8.6 Filtration Options Recirculation filtration of
either QC tanks or the Product storage tank is important
to control particle levels in the final chemical.
Recirculation filtration options should be provided,
depending on the specific chemical storage
configuration.
NOTICE: These standards do not purport to address
safety issues, if any, associated with their use. It is the
responsibility of the user of these standards to establish
appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
SEMI makes no warranties or representations as to the
suitability of the standards set forth herein for any
particular application. The determination of the
suitability of the standard is solely the responsibility of
the user. Users are cautioned to refer to manufacturer's
instructions, product labels, product data sheets, and
other relevant literature respecting any materials
mentioned herein. These standards are subject to
change without notice.
The user's attention is called to the possibility that
compliance with this standard may require use of
copyrighted material or of an invention covered by
patent rights. By publication of this standard, SEMI
takes no position respecting the validity of any patent
rights or copyrights asserted in connection with any
item mentioned in this standard. Users of this standard
are expressly advised that determination of any such
patent rights or copyrights, and the risk of infringement
of such rights, are entirely their own responsibility.
Copyright by SEMI® (Semiconductor Equipment and Materials
International), 3081 Zanker Road, San Jose, CA 95134. Reproduction o
f
the contents in whole or in part is forbidden without express written
consent of SEMI.

SEMI F47-0200 © SEMI 1999, 20001
SEMI F47-0200
SPECIFICATION FOR SEMICONDUCTOR PROCESSING EQUIPMENT
VOLTAGE SAG IMMUNITY
This specification was technically approved by the Global Facilities Committee and is the direct
responsibility of the North American Facilities Committee. Current edition approved by the North American
Regional Standards Committee on December 15, 1999. Initially available on www.semi.org January 2000; to
be published February 2000. Originally published September 1999.
1 Purpose
1.1 Semiconductor factories require high levels of
power quality due to the sensitivity of equipment and
process controls. Semiconductor processing equipment
is especially vulnerable to voltage sags. This document
defines the voltage sag ride-through capability required
for semiconductor processing, metrology, and
automated test equipment.
1.2 The requirements in this international standard
were developed to satisfy semiconductor industry
needs. While more stringent than existing generic
standards, this industry-specific specification is not in
conflict with known generic equipment regulations
from other regions or generic equipment standards from
other organizations (see Related Information section).
1.3 It is the intent of this standard to provide
specifications for semiconductor processing equipment
that will lead to improved selection criteria for sub-
components and improvements in equipment systems
design. While it is recognized that in certain extreme
cases or for specific functions battery storage devices
may be appropriate, it is not the intent of this standard
to increase the size or use of battery storage devices
provided with equipment. Focus on improvements in
equipment component and system design should lead to
a reduction or elimination in the use of battery storage
devices to achieve equipment reliability during voltage
sag events.
2 Scope
2.1 This document specifies the minimum voltage sag
ride-through capability design requirements for
equipment used in the semiconductor industry. The
expected equipment performance capability is shown
graphically on a chart representing voltage sag duration
and percent deviation of equipment nominal voltage.
Standard evaluation test method references are also
included.
2.2 The primary focus for this specification is
semiconductor processing equipment including but not
limited to the following tool types:
• Etch equipment (Dry & Wet),
• Film deposition equipment (CVD & PVD),
• Thermal equipment,
• Surface prep and clean,
• Photolithography equipment (Stepper & Tracks),
• Chemical Mechanical Polishing equipment,
• Ion Implant equipment,
• Metrology equipment, and
• Automated test equipment.
2.3 This specification applies to se miconductor
processing equipment to include the equipment
mainframe and all subsystems whose electrical power is
directly affected by the operation of the equipment’s
EMO system.
2.4 This standard does not purport to address safety
issues, if any, associated with its use. It is the
responsibility of the users of this standard to establish
appropriate safety and health practices and determine
the applicability of regulatory limitations prior to use.
3 Limitations
3.1 Not included in this standard are over voltage
conditions, voltage sag duration of less than 0.05
seconds (50 milliseconds), and voltage sag duration of
greater than 1.0 seconds. If necessary, the Information
Technology Industry Council (ITIC) “CBEMA-curve”
contained in IEEE 446, IEEE 1100, and SEMI E51 can
be used to specify additional requirements outside the
range of this document (see Related Information,
Section R1-1).
3.2 This specification does not address wafer quality
with regard to processing variation caused by voltage
sags. It is recommended that each equipment supplier
consider the effects of voltage sags on their equipment
processes. If voltage sags above the defined line can
result in known wafer quality problems, then an appro-
priate notification-only scheme should be considered in
the equipment design. To be in conformance with this
standard that notification scheme should not be
classified as an equipment interrupt per SEMI E10.
3.3 This standard addresses specifications for
semiconductor processing equipment voltage sag
immunity. Factory systems voltage sag immunity and
electric utility voltage sag performance are covered in