SEMI F70-0302 © SEMI 2002 3 8 Preparatio n of Apparatus 8.1 Set u p apparatus and the g as supply system as show n in Fi gure 1. NV RG F N2 By-pass MFM Syst em Under Test Part ic le Counter Sam ple r F F MFC VENT V Legen…

SEMI F70-0302 © SEMI 2002
2
5.2.7 particle counts — a counted value from a laser particle counter (LPC) or condensation nucleus counter (CNC)
shown for particles or larger than or equal to the minimum counting particle diameter.
5.2.8 sample flow rate — the volumetric flow rate through the particle counter.
5.2.9 spool piece — a null component consisting of a straight piece of electropolished tubing or like object and
appropriate fittings used in place of the test system to establish the background.
5.2.10 test flow rate — the volumetric flow rate through the test systemRequired Apparatus
6 Required Apparatus
6.1 Filter — Filters with the following performance specified by the manufacturer.
Characteristic Performance Condition
Filtration Efficiency
9 log particle size: 0.02 µ m
Flow Rate
300 slm inlet pressure: 0.34 MPa
6.2 Tubing Material — 1/4 inch or 3/8 inch SUS 316L electropolished tubing or better.
6.3 Particle Counter — The particle counter may be either LPC or CNC of which the minimum counting particle
diameter is 0.1 µ m or smaller, and has the following performance as specified by JIS B 9921.
6.3.1 Counting Efficiency
Diameter of Polystyrene Latex Standard Particle Counting Efficiency
Minimum countable particle diameter of the counter (See NOTE 1.)
50 ± 20 %
1.5 to 2.0
×
Minimum countable particle diameter of the counter
100 ± 10 %
NOTE 1: For a CNC, the minimum countable diameter shall be defined as a diameter having counting efficiency of 50 ± 20%.
6.3.2 False Count — Equal to or less than 1 in 5 minutes.
6.3.3 Acceptable Error of Flow Rate — ± 5%
6.4 Sampler — A system used to perform partial sampling of the gas stream exiting the test system, that consists of
a diffuser equipped with a pressure reducing device in which gradual expansion to atmospheric pressure occurs and
a sample probe. It is desirable that the sampler is designed to obtain isokinetic sampling. The average velocity of
gas flowing through the sample probe should approximate the average velocity in the external tubing in which the
sample probe is inserted. The sample probe overlap with the external tube must be of appropriate length, and it must
be confirmed before use that the surrounding atmospheric gas is not drawn in the sample.
7 Test Condition
7.1 Test Gas — Liquid Nitrogen (LN
2
) or cleaner Nitrogen (N
2
) or Argon (Ar).
7.2 Temperature — Room temperature (between 18 and 26° C)
7.3 Environment — ISO/FDIS 14644-1 class 5 or better.

SEMI F70-0302 © SEMI 2002
3
8 Preparation of Apparatus
8.1 Set up apparatus and the gas supply system as shown in Figure 1.
NV
RG F
N2
By-pass
MFM
System
Under
Test
Particle
Counter
Sampler
F
F
MFC
VENT
V
Legend, V: Valve MFC: Mass Flow Controller MFM: Mass Flow Meter
F: Filter RG: Regulator NV: Needle Valve
Figure 1
Test Set Up Basic Flow Diagram
8.2 If the test flow rate is equal to or less than the sample flow rate required by the particle counter, insert a filter in
place of the sampler to fulfill the sample flow rate. (See Figure 2.)
Test
Flow
Particle
Counter
Filter
Test Flow Rate
≤
Sample Flow Rate
Figure 2
Full Sampling
8.3 If the test flow rate is higher than the sample flow rate required by the particle counter, use the sampler for
partial sampling. (See Figure 3.) To establish the test flow rate and obtain an isokinetic condition, it is required to
adjust the MFC in the test set up and the NV on the by-pass line. The by-pass line is required to have a capability to
handle the maximum test flow when the valves in the system under test is closed position during the pulse test.
Sampler
Particle
Counter
Test
Flow
Vent
FNV
By-pass
Test Flow Rate
>
Sample Flow Rate
Figure 3
Partial Sampling

SEMI F70-0302 © SEMI 2002
4
9 Procedure
9.1 A typical gas delivery system configuration is shown in Figure 4. The following test procedure shall be
interpreted to apply to the actual test system and recorded by the operator.
V2 V4 V6
V1 V3 V5
F1
F2 F3
MFC1 MFC2 MFC3
LINE1 LINE2 LINE3
LEGEND
V1 - 6 Valves
F1 - 3 Filters
MFC1 -3 Mass Flow
Controllers
System Under Test
Figure 4
Typical Gas Delivery System Configuration
9.2 Determination of Background Counts
9.2.1 For test set up, insert a spool piece in place of the
system under test (i.e. the gas delivery system) as in
Figure 1.
9.2.2 Establish the test flow rate as 1.5 times of the
design flow rate and supply N
2
(or Ar). In this case the
design flow rate is determined as the flow rate of the
line which has maximum flow rate in the system under
test. Purge the test set up for more than 10 minutes.
9.2.3 Confirm the particle count is not more than 1
during 10 minutes after the purge. If the total volume of
the test flow is less than 28.3 liters, extend the sampling
time until it achieves more than 28.3 liters. If the
particle count is more than 1, repeat Sections 9.2.2 and
9.2.3.
9.2.4 Replace the spool piece with the test system.
9.3 Static Flow Test
9.3.1 Close all valves in the line 2 and 3, set the MFCs
as full scale or purge mode if available and fully open
the valves in the line 1.
9.3.2 Supply N
2
(or Ar) to the line 1 with 1.5 times of
the design flow rate of the line 1 and purge the test set
up for more than 10 minutes. In many case, this will
require the activation of the valve override on any
MFCs on the test line. It is also required to verify that
all components in the system can withstand 1.5 times
the design flow rate.
9.3.3 Count particles for more than 10 minutes. If the
total volume of the test flow is less than 28.3 liters,
extend the sampling time until it achieves more than
28.3 liters.
9.3.4 Repeat Sections 9.3.2 and 9.3.3 per all lines.
9.4 Pulse Flow Test
9.4.1 Close all valves in the line 2 and 3, set the MFCs
as full scale or purge mode if available and fully open
the valves in the line 1.
9.4.2 Supply N
2
(or Ar) to the line 1 with 1.5 times of
the design flow rate of the line 1 and purge the test set
up for more than 10 minutes.
9.4.3 Actuate V1 at the rate of 30 cycles/minute for 10
minutes if V1 is pneumatically operated valve. For
manually operated valve, actuate the valve at 4
cycles/minute for 10 minutes. Each cycle consists of on
and off actuation of the valve. The on and off cycles
should be of equal duration. If the total volume of the
test flow is less than 28.3 liters, extend the sampling
time until it achieves more than 28.3 liters. Count
particles during the period.
9.4.4 Repeat Section 9.4.3 for V2.