SEMI MF1390-1104 © SEMI 2004 1
SEMI MF1390-1104
TEST METHOD FOR MEASURING WARP ON SILICON WAFERS BY
AUTOMATED NON-CONTACT SCANNING
This test method was technically approved by the Global Silicon Wafer Committee and is the direct
responsibility of the North American Silicon Wafer Committee. Current edition approved for publication by
the North American Regional Standards Committee on August 16, 2004. Initially available at
www.semi.org
September 2004; to be published November 2004. Original edition published by ASTM International as
ASTM F 1390-92. Last previous edition SEMI MF1390-0704.
1 Purpose
1.1 Warp can significantly affect the yield of
semiconductor device processing.
1.2 Knowledge of this characteristic can help the
producer and consumer determine if the dimensional
characteristics of a specimen wafer satisfy given
geometrical requirements.
1.3 Changes in wafer warp during processing can
adversely affect subsequent handling and processing
steps. These changes can also provide an important
process monitoring function.
1.4 This test method is suitable for measuring the warp
of wafers used in semiconductor device processing in
the as-sliced, lapped, etched, polished, epitaxial or other
layer condition and for monitoring thermal and
mechanical effects on the warp of wafers during device
processing.
2 Scope
2.1 This test method covers a non-contacting,
nondestructive procedure to determine the warp of
clean, dry semiconductor wafers.
2.2 This test method employs a two-probe system that
examines both external surfaces of the wafer
simultaneously.
2.3 The test method is applicable to wafers 50 mm or
larger in diameter, and approximately 100 m and
larger in thickness, independent of thickness variation
and surface finish, and of gravitationally induced wafer
distortion.
2.4 This test method is not intended to measure the
flatness of either exposed silicon surface. Warp is a
measure of the distortion of the median surface of the
wafer.
2.5 This test method measures warp of a wafer
corrected for mechanical forces applied during the test.
Therefore, the procedure described gives the
unconstrained value of warp.
NOTE 1: This warp is indicated by the acronym
“GMLYMER” in Appendix 2, Shape Decision Tree, of SEMI
M1.
NOTE 2: SEMI MF657 measures median surface warp using
a three-point back-surface reference plane. The back-surface
reference results in thickness variation being included in the
recorded warp value. The use (in this test method) of a
median surface reference plane eliminates this effect. The use
(in this test method) of a least-squares fit reference plane
reduces the variability introduced in three-point plane
calculations by choice of reference point location. The use (in
this test method) of special calibration or compensating
techniques minimizes the effects of gravity-induced distortion
of the wafer.
2.6 This test method includes several methods for
canceling gravity-induced deflection which could
otherwise alter the shape of the wafer.
1
NOTE 3: One of these methods, the Representative Wafer
Inversion Method, is covered by a patent held by ADE
Corporation, 80 Wilson Way, Westwood, MA 02090-1806.
NOTICE: This standard does not purport to address
safety issues, if any, associated with its use. It is the
responsibility of the user of this standard to establish
appropriate safety and health practices and determine
the applicability of regulatory or other limitations prior
to use.
3 Limitations
3.1 Any relative motion along the probe measuring axis
between the probes and the wafer holding device during
scanning will produce error in the measurement data.
Vibration of the test specimen relative to the probe-
measuring axis will introduce error. Such errors are
minimized by system signature analysis and correction
algorithms. Internal system monitoring may also be
used to correct non-repetitive and repetitive system
mechanical translations. Failure to provide such
corrections may cause errors.
3.2 If a measured wafer differs substantially in
diameter, thickness, fiducials, or crystal orientation
from that used for the gravitational compensation
procedure, the results may be incorrect. Estimates of
the errors in gravity induced deflection for differences
1 Poduje, N., “Eliminating Gravitational Effect in Wafer Shape
Measurements,” NIST/ASTM/SEMI/SEMATECH Technology Confe-
rence, Dallas, TX. Technology for Advanced Materials/Process
Characterization, February 1, 1990.
SEMI MF1390-1104 © SEMI 2004 2
in diameter and thickness are shown in Related
Information 1. If the crystal orientation of the sample
to be measured differs from the crystal orientation of
the gravity-compensation wafer, then the measured
warp value may differ from the actual warp value by up
to 15%. Error tables for fiducial variation have not
been generated.
3.3 Different methods for implementing gravitational
compensation may give different results. Varying
levels of completeness of implementing a method may
also give different results.
3.4 Mechanical variations in wafer holding devices
between systems may introduce measurement
differences. This test method allows the use of a
variety of wafer holding devices (see Section 7.1.4.1);
results obtained with different geometrical
configurations of wafer holding device on the same test
samples may differ.
3.5 Most equipment systems capable of this
measurement have a definite range of wafer thickness
combined with warp (dynamic range) that can be
accommodated without readjustment. If the sample
moves outside this dynamic range during either
calibration or measurement, results may be in error. An
over-range signal can be used to alert the operator and
measurement data examiners to this event.
3.6 The quantity of data points and their spacing may
affect the measurement results. This test method does
not specify the data point spacing (see Section 7.1.4.2);
results obtained with different data point spacings on
the same test samples may differ.
4 Referenced Standards
4.1 SEMI Standards
SEMI M1 — Specifications for Polished
Monocrystalline Silicon Wafers
SEMI MF657 — Test Method for Measuring Warp and
Total Thickness Variation on Silicon Wafers by
Noncontact Scanning
SEMI MF1241 — Terminology of Silicon Technology
SEMI MF1530 — Test Method for Measuring Flatness,
Thickness, and Thickness Variation on Silicon Wafers
by Automated Non-contact Scanning
4.2 ASTM Standard
E 691 — Practice for Conducting an Interlaboratory
Study to Determine the Precision of a Test Method
2
2 Available from ASTM International, 100 Barr Harbor Drive, West
Conshohocken, PA 19428, Tel: 610-832-9500, Fax: 610-832-9555,
Website
http://www.astm.org. Appears in Volume 14.02 of Annual
Book of ASTM Standards.
NOTICE: Unless otherwise indicated, all documents
cited shall be the latest published versions.
5 Terminology
5.1 Definitions
5.1.1 mechanical signature, of an instrument — that
component of a measurement that is introduced by the
instrument and that is systematic, repeatable, and
quantifiable.
5.1.2 median surface, of a semiconductor wafer — the
locus of points equidistant from the front and back
surfaces of the wafer.
5.1.3 reference plane, of a semiconductor wafer — a
plane from which deviations of a specified surface of
the wafer are measured.
5.1.4 reference plane deviation (RPD) — the distance
from a point on a reference plane to the corresponding
point on a wafer surface.
5.1.4.1 Discussion — A dome-shaped wafer is
considered to have positive RPD at its center; a bowl-
shaped wafer is considered to have negative RPD at its
center.
5.1.5 thickness, of a semiconductor wafer — the
distance through the wafer between corresponding
points on the front and back surfaces.
5.1.6 warp, of a semiconductor wafer — the algebraic
difference between the most positive and the most
negative deviations of the median surface of a wafer
that is not chucked from a reference plane that is a least
squares fit to the median surface.
5.1.6.1 Discussion — Although warp may be caused by
unequal stresses on the two exposed surfaces of the
wafer, it cannot be determined from measurements on
a single exposed surface. The median surface may
contain regions with upward or downward curvature or
both; under some conditions the median surface may be
flat. In all cases, warp is a zero or positive quantity.
Stylized examples of visualization of warp are shown in
SEMI MF657.
5.2 Definitions of other terms related to silicon material
technology can be found in SEMI MF1241.
6 Summary of Test Method
6.1 A calibration procedure is performed to set the
instrument's scale factor and other constants. If the
representative wafer inversion method is used for
gravity correction, the calibration procedure also
determines the mechanical signature of the instrument
and the effect of gravity on the wafer.
SEMI MF1390-1104 © SEMI 2004 3
6.2 The wafer is supported by a small-area chuck with
front surface up.
6.3 Both external surfaces are simultaneously scanned
along a prescribed pattern by an opposed pair of probes
to obtain a set of values of the distances between each
surface and the nearest probe. In each case, both
members of the pair of distances is taken at the same
value of the x and y coordinates.
6.4 The paired displacement values are used to
construct the median surface.
6.5 A correction for gravity effects on the median
surface is made either by subtracting a gravity
correction obtained (1) from measurements on a
representative wafer or (2) from theoretical
considerations or by repeating the scan with the wafer
inverted.
6.6 A least-squares reference plane is constructed from
the corrected median surface.
6.7 The reference plane deviation (RPD) is calculated at
each measured pair of points.
6.8 Warp is reported as the algebraic difference
between the most positive RPD and the most negative
RPD.
7 Apparatus
7.1 Measuring Equipment, consisting of wafer holding
device, multiple-axis transport mechanism, probe
assembly with indicator, and system
controller/computer, including data processor and suit-
able software.
7.1.1 The equipment shall be direct reading with all
necessary calculations performed internally and
automatically as outlined in Section 11.2.
7.1.2 The equipment shall be equipped with an over-
range signal.
7.1.3 Instrument data reporting resolution shall be 100
nm or smaller.
7.1.4 The measuring equipment contains the following
subsystems:
7.1.4.1 Wafer-holding device, for example a chuck
whose face is perpendicular to the measurement axis,
and on which the wafer is placed for the measurement
scan. The nature and size of the wafer holding device
shall be agreed upon between the parties to the test.
7.1.4.2 Multiple-axis transport mechanism, which
provides a means for moving the wafer-holding device,
or the probe assembly, perpendicularly to the
measurement axis in a controlled fashion in several
directions. This motion must permit data gathering
over a prescribed scan pattern covering the entire fixed
quality area. Data point spacing to be used shall be
agreed upon between the parties to the test.
Figure 1
Schematic View of Wafer, Probes, and Fixture
7.1.4.3 Probe assembly with paired non-contacting
displacement-sensing probes, probe supports, and
indicator unit (see Figure 1).
7.1.4.3.1 The probes shall be capable of independent
measurement of the distances a and b between the
probed site on each surface of the sample wafer and the
nearest probe surface.
7.1.4.3.2
The probes shall be mounted above and
below the wafer in a manner so that the probed site on
one surface of the wafer is opposite the probed site on
the other.
7.1.4.3.3 The common axis of these probes is the
measurement axis.
7.1.4.3.4 The probe separation D shall be kept constant
during calibration and measurement.
7.1.4.3.5 Displacement resolution shall be 100 nm or
smaller.
7.1.4.3.6 The probe sensor size shall be 4 mm by 4
mm, or other value to be agreed upon between the
parties to the test.
7.1.4.3.7 Measuring equipment employing either the
Representative Wafer Inversion Method or the Sample
Wafer Inversion Method for gravity compensation must
provide precise positioning in both measurement
orientations so that measurements are taken at identical
locations for each orientation of the sample.
8 Materials
8.1 Set-up Masters — suitable to accomplish
calibration and standardization as recommended by the
equipment manufacturer.
8.2 Reference Waferwith a reference warp value
20 m that is used to determine the level of agreement