semi合集-English.pdf - 第7537页

SEMI MF1809-0704 © SEMI 2003, 2004 2 3.1.7 The samples m ust be free of wor k damage, contaminati on, and other c omplicating resi dues. Clean, specular surfaces are suit able for metallographic examination and provi de …

100%1 / 7923
SEMI MF1809-0704 © SEMI 2003, 2004 1
SEMI MF1809-0704
GUIDE FOR SELECTION AND USE OF ETCHING SOLUTIONS TO
DELINEATE STRUCTURAL DEFECTS IN SILICON
This guide was technically approved by the Global Silicon Wafer Committee and is the direct responsibility
of the North American Silicon Wafer Committee. Current edition approved for publication by the North
American Regional Standards Committee on April 22, 2004. Initially available at www.semi.org May 2004;
to be published July 2004. Original edition published by ASTM International as ASTM F 1809-97. Last
previous edition SEMI MF1809-02.
1 Purpose
1.1 Structural defects formed in the bulk of a silicon
wafer during its growth or induced by electronic device
processing can affect the performance of the circuitry
fabricated on that wafer. These defects take the form of
dislocations, slip, stacking faults, shallow pits, or
precipitates.
1.2 The exposure of the various defects found on or in
a silicon wafer is often the first critical step in
evaluating wafer quality or initiating failure analysis of
an errant device structure. Etching often accomplishes
this task. This guide provides information on the
selection and application of appropriate etching
solutions.
2 Scope
2.1 This guide covers the formulation, selection, and
use of chemical solutions developed to reveal structural
defects in silicon wafers.
2.2 Sample preparation, temperature control, etching
technique, and choice of etchant are all key factors in
the successful use of an etching method. This guide
provides information for several etching solutions and
provides guidance for the user to select according to the
need. Illustrations of results obtained with these
etching solutions are provided in Figures 1–32.
2.3 This guide is intended for use with other practices
and test methods. SEMI MF1725 and SEMI MF1726
are practices for analysis of crystallographic perfection
of silicon ingots and wafers, respectively, utilizing
etching solutions found in this guide, and followed by
counting in accordance with the test method SEMI
MF1810. SEMI MF1727 defines the procedures for
oxidation of the wafer prior to etching, if that is
required to expose the defect structures of interest. JIS
H 0609 is a test method that covers the entire process of
determining crystalline defects in silicon wafers.
2.4 Both this guide and JIS H 0609 emphasize the use
of etching solutions that do not contain chromic acid,
which is biologically and ecologically very hazardous
(see Section 7.6). Because of the hazardous nature of
chrome containing etchants, the use of chromic acid
containing etchants is prohibited in some jurisdictions
located in various parts of the world.
NOTE 1: See Related Information 1 for a discussion of the
relationships between this guide and JIS H-0609.
NOTICE: This standard does not purport to address
safety issues, if any, associated with its use. It is the
responsibility of the user of this standard to establish
appropriate safety and health practices and determine
the applicability of regulatory or other limitations prior
to use.
3 Limitations
3.1 Complicating factors are different for each etchant.
Research the choice of etchants in advance to ensure
the method and solution are compatible with the sample
and objectives. Commonly encountered problems are:
3.1.1 Inadvertent etching through the denuded zone of
an oxidized sample delineates irrelevant bulk defects
instead of the surface oxidation induced stacking faults
(OISF) expected.
3.1.2 Accelerated etching and etching artifacts can
result from excessive solution heating during the
etching process.
3.1.3 Insufficient agitation, bubble formation or
particles in the etching solution can generate artifacts
on the silicon surface that mimic actual defects.
Insufficient agitation can alter the etching rate,
increasing or decreasing it depending upon the
formulation.
3.1.4 Any solution in which the oxidation rate is
greater than the oxide dissolution rate may form oxide
layers that slow or even quench the etching process.
The presence of these oxide layers (especially for n
+
and p
+
material) obstructs the interpretation of etched
defects. Before evaluation, remove any surface oxides.
3.1.5 The wafer surface becomes rougher with longer
etch time. This rougher surface does not prevent evalu-
ation under the microscope, but it greatly reduces the
effectiveness of visual inspection under bright light.
3.1.6 Etching solutions can generate false pits that are
not associated with defects.
SEMI MF1809-0704 © SEMI 2003, 2004 2
3.1.7 The samples must be free of work damage,
contamination, and other complicating residues. Clean,
specular surfaces are suitable for metallographic
examination and provide the best results. Surfaces
examined should be flat with parallel faces, to simplify
microscope inspection.
4 Referenced Standards
4.1 SEMI Standards
SEMI C18 — Specification for Acetic Acid
SEMI C28 — Specifications and Guidelines for
Hydrofluoric Acid
SEMI C35 — Specifications and Guidelines for Nitric
Acid
SEMI MF523 — Practice for Unaided Visual
Inspection of Polished Silicon Wafer Surfaces
SEMI MF1241 — Terminology of Silicon Technology
SEMI MF1725 — Practice for Analysis of
Crystallographic Perfection of Silicon Ingots
SEMI MF1726 — Practice for Analysis of
Crystallographic Perfection of Silicon Wafers
SEMI MF1727 — Practice for Detection of Oxidation
Induced Defects in Polished Silicon Wafers
SEMI MF1810 — Test Method for Counting
Preferentially Etched or Decorated Surface Defects in
Silicon Wafers
4.2 ASTM Standard
1
D 5127 — Guide for Ultra Pure Water Used in the
Electronics and Semiconductor Industry
4.3 Japan Industrial Standard
2
JIS H 0609 — Test Methods Of Crystalline Defects In
Silicon By Preferential Etch Techniques
NOTICE: Unless otherwise indicated, all documents
cited shall be the latest published versions.
5 Terminology
5.1 Defect-related terminology may be found in SEMI
MF1241.
1 Annual Book of ASTM Standards, Vol. 11.01. ASTM International,
100 Barr Harbor Drive, West Conshohocken, PA 19428. Telephone:
610-832-9500. Fax: 610-832-9555. Website:
www.astm.org.
2 Available, in Japanese language edition only, through the Japanese
Standards Association, 1-24, Akasaka 4-Chome, Minato-ku, Tokyo
107-8440, Japan. Telephone: 81.3.3583.8005; Fax: 81.3.3586.2014
Website: www.jsa.or.jp
6 Apparatus
6.1 No standard apparatus or facility satisfies the
universal needs for the various applications of these
etching solutions. Systems range from a simple HF-
resistant beaker to large etching tanks complete with
nitrogen bubblers, temperature control and nitrous
oxide and hydrofluoric acid (HF) scrubbers.
6.1.1 For larger samples (wafers or slugs), use large
etching tanks with nitrogen bubble agitation or
ultrasonic agitation. Most of the etchant solutions listed
work more effectively with the aid of agitation. Heat
exchangers or just the thermal mass of the solution can
control temperature. Large volumes of acid heat more
slowly and allow an intrinsic form of temperature
control. To reduce heating effects, maintain 1 L of
solution for each 1,000 cm
2
of sample surface area.
6.1.2 Maintain proper environmental controls. Make
provisions to dispose of nitrous oxides, HF fumes, and
any solid wastes evolved whatever system is chosen.
Chromium and copper-based etching solutions produce
solid waste and gaseous byproducts. Chromium-free
etching solutions produce no measurable solid waste
but do generate nitrous oxides and HF fumes.
7 Reagents and Materials
7.1 Purity of Reagents — Chemicals shall conform to
the assay and impurity levels of Grade 1 SEMI
Specifications where they exist. Reagents for which
SEMI specifications have not been developed shall
conform to the specifications of the Committee on
Analytical Reagents of the American Chemical
Society,
3
where such specifications are available. Other
grades may be used provided it is first ascertained that
the reagent is of sufficiently high purity to permit its
use without lessening the accuracy of the determination.
7.2 Purity of Water — Reference to water shall be
understood to mean Type E-3 or better water as
described in ASTM Guide D 5127.
7.3 Volume of components describes all solutions in
parts of a standard assay. The formulas give solid or
dissolved components in grams per 100 mm of total
solution.
7.4 All formulations employ a Standard Solution
Convention (SSC) that specifies each solution
component as an acceptable assay ± some tolerance.
3 Reagent Chemicals, American Chemical Society Specifications,
American Chemical Society, Washington, DC. For suggestions on the
testing of reagents not listed by the American Chemical Society, see
Analar Standards for Laboratory Chemicals, BDH Ltd., Poole,
Dorset, U.K., and the United States Pharmacopeia and National
Formulary, U.S. Pharmacopeial Convention, Inc., (USPC), Rockville,
MD.
SEMI MF1809-0704 © SEMI 2003, 2004 3
Formulations of the standard assay follow this example:
A HF/HNO
3
/Acetic solution, in the 1:1:2 ratio is the
same as 25% (49% HF) + 25% (70% HNO
3
+ 50%
(glacial acetic) by volume. The specified chemicals
shall have the following nominal assay:
Acetic acid, glacial >99.7%
Chromium trioxide >98%
Copper nitrate >98%
Hydrofluoric acid 49± 0.25%
Nitric acid 70 to 71%
7.5 The chemicals used in these etching solutions are
potentially harmful. Handle and use them in a chemical
exhaust fume hood, with the utmost care. Hydrofluoric
acid solutions are particularly hazardous.
7.6 Release of chromic acid or solutions of chromic
acid into domestic sewer systems is usually not
allowed. Chromates are extreme biological and
ecological hazards. Chromic acid is a strong oxidizing
agent and should not contact organic solvents or other
easily oxidized materials.
7.7 Safety or protective gear should be worn while
handling these acid solutions or their components.
Safety requirements vary, but essential items are plastic
gloves, safety glasses, face shield, acid gown, and shoe
covers. The handling of large quantities of powdered
chromic acid may require a respirator or other breathing
apparatus.
8 Procedure
8.1 Selection of Etching Solutions
8.1.1 The following tables show two broad categories
of solutions. The first group in Tables 1 and 3 includes
only chromium-free etching solutions. Although uses
may be limited, these solutions should be considered
whenever appropriate. The second group in Tables 2
and 4 includes only solutions that contain chromium
compounds. These do well for their intended
applications, but they can be harmful to the
environment. Use these highly contaminated etching
solutions with caution. Release into the environment of
hexavalent chromium waste is a recognized hazard (see
Section 7.6). Exposure can cause cancer.
NOTE 2: Copper-3 solution is also identified as “MEMC
etch” in referenced publications.
NOTE 3: Sopori and Sato etches have been suggested for
inclusion in Tables 2 and 4, and these solutions may be added
when solution information and pictures become available
from sponsors (see Related Information 2 for the
methodology by which new solutions can be added to the
guide).
8.1.2 Tables 1 and 2 list the figure numbers of the
etched defect examples for these etching solutions
together with their etching rates.
8.1.3 Tables 3 and 4 classify the suitability of each
listed etching solution for the various applications. In
the tables,
A = Excellent,
B = Good,
C = Acceptable, and
D = Unacceptable.
Each solution has advantages and disadvantages and
this guide does not endorse one in favor of another.
Selection of an etchant solution should be based upon
etch rate, etchant life, solution heating, environmental
harm, ease of interpretation, and range of use.
8.1.4 Investigate local environmental and safety
requirements before selecting an etchant solution.
Identify the sample orientation, type, resistivity level,
and primary defects of interest; this information helps
the user rank the various possible solutions and then
select the most appropriate choice.
8.1.4.1 Although this guide does not require a specific
solution, it is highly recommended that chromium-free
etching solutions should be used whenever possible, for
environmental and biological reasons.
8.2 Sample Preparation
8.2.1 Most silicon samples have residual oxide on the
surface, either thermally grown as part of the
fabrication process or occurring naturally due to
exposure to air.
8.2.2 Immediately before defect etching, submerge the
sample in concentrated HF solution for 1 min or until
the surface becomes hydrophobic to remove surface
oxide layers.
8.2.3 Rinse and hold the samples in deionized water
until transferred to the etching solution.
8.3 Defect Etching
8.3.1 No standard design for etching systems exists
(see Section 6.1). In general, the procedures defined for
the etching system available to the user of this guide
must be followed. A simple system for manual use is
as follows:
8.3.1.1 Place the specimen in the bottom of a HF-proof
beaker with the surface to be inspected facing upward.
8.3.1.2 Pour in sufficient etchant to cover the specimen
with about 2 cm of solution.